1F7 (Cm); 1F6 (Dh) Dv; 1F5 (Ch); 1F4 (Cl) - Fujitsu MHG2102AT - Mobile 10 GB Hard Drive Product Manual

Disk drives
Hide thumbs Also See for MHG2102AT - Mobile 10 GB Hard Drive:
Table of Contents

Advertisement

Interface
1F7
1F6
1F5
1F4
1F3
1F2
1F1
1F7
1F6
1F5
1F4
1F3
1F2
1F1
(11) INITIALIZE DEVICE PARAMETERS (X'91')
The host system can set the number of sectors per track and the maximum head
number (maximum head number is "number of heads minus 1") per cylinder with
this command. Upon receipt of this command, the device sets the BSY bit of
Status register and saves the parameters. Then the device clears the BSY bit and
generates an interrupt.
When the SC register is specified to X'00', an ABORTED COMMAND error is
posted. Other than X'00' is specified, this command terminates normally.
The parameters set by this command are retained even after reset or power save
operation regardless of the setting of disabling the reverting to default setting.
In LBA mode
The device ignores the L bit specification and operates with the CHS mode
specification. An accessible area of this command within head moving in the LBA
mode is always within a default area. It is recommended that the host system refers the
addressable user sectors (total number of sectors) in word 60 to 61 of the parameter
information by the IDENTIFY DEVICE command.
5-30
At command issuance (I/O registers setting contents)
(CM)
0
1
H
(DH)
L
H
(CH)
Cylinder No. [MSB] / LBA
H
(CL)
Cylinder No. [LSB] / LBA
H
(SN)
Sector No. / LBA [LSB]
H
(SC)
xx
H
(FR)
xx
H

At command completion (I/O registers contents to be read)

(ST)
Status information
H
(DH)
L
H
(CH)
Cylinder No. [MSB] / LBA
H
(CL)
Cylinder No. [LSB] / LBA
H
(SN)
Sector No. / LBA [LSB]
H
(SC)
xx
H
(ER)
Error information
H
1
1
x
x
DV
Head No. /LBA [MSB]
DV
Head No. /LBA [MSB]
x
x
C141-E070-01EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhh2032atMhh2064atMhh2048at