3.1
Site Considerations
The site where you install the DSN-1100 storage system can affect its performance.
Therefore, choose a site that conforms to the requirements in the following sections.
3.1.1
General Considerations
Observe the following considerations when selecting a location to install the DSN-1100
storage system.
The location should be fairly cool and dry for the acceptable temperature and humidity
ranges.
The location should be free of strong electromagnetic field generators (such as motors),
vibration, dust, and direct exposure to sunlight.
The location must provide sufficient airflow to the front and back of the DSN-1100
storage system for correct cooling. Ventilation must be sufficient to exhaust heat from
the rear of the equipment.
The location should offer a power outlet within six feet (1.82 meters) of the DSN-1100
storage system.
The location should allow for at least six inches (152.3 mm) of space around the DSN-
1100 storage system for ventilation.
Do not place the DSN-1100 storage system next to, on top off, or below any device that
generates a significant amount of heat or will block the fee flow of air through the DSN-
1100 ventilation slots.
3.1.2
Desktop, Floor or Shelf Installation
The DSN-1100 storage system can be placed on a desktop, floor or shelf. Observe the
following considerations for installations.
Select a sturdy, level surface that can support the DSN-1100 storage system. A fully
populated unit weighs approximately 8.8 lbs. (4.0 kg.).
Allow enough ventilation space between the DSN-1100 storage system and any other
objects in the vicinity.
Be sure not to block the air vents on the front and back of the DSN-1100 storage system
enclosure. Install the cables and power cord according to the procedures in the following
sections.
20
Chapter 3 Installing the DSN-1100 Storage System