Upgrading The Firmware On All Disks - HP 6100 Software Manual

Hp storageworks 4x00/6x00/8x00 enterprise virtual array updating product software guide (xcs 6.220) (5697-0459, october 2010)
Hide thumbs Also See for 6100:
Table of Contents

Advertisement

supplied with the system software upgrade complements the operation of the controller firmware
and for the best results the two should be used together.
When upgrading many (more than about 20) disk drives online, a loop may fail; to reduce the
chance of such a loop failure, upgrade about 15 or 20 drives, then pause the activity for several
minutes by navigating away from the upgrade. Continue after a few minutes. To proceed after
such a pause, review the controller logs to establish where you are in the upgrade process and
relaunch the online upgrade. The upgrade will start where it left off.
CAUTION:
Observe the following cautions when upgrading disk drive firmware:
Do not power off any components or perform controller resynchs or reboots during an upgrade.
Do not perform HP Continuous Access EVA copy/merge activities across sites, site failovers,
cloning, or grouping or ungrouping of disks during an upgrade.
Do not add to or remove members from DR groups during upgrade.
Ensure that you upgrade the disk drive firmware after you upgrade the storage system software.
Perform your upgrade during times of low I/O to minimize the time it takes to revert information
back onto the drive after the upgrade.
If an error occurs during the upgrade, the process stops and must be restarted to upgrade disks
that have not yet been upgraded. Any disks that were upgraded before the error occurred do not
have to be upgraded again. Check the logs to verify status. When you restart the process, it starts
at the next disk that needs the upgrade.

Upgrading the firmware on all disks

Upgrade the disk drive firmware after you upgrade the system software.
1.
Validate that adequate free space is available to manage disk failures that might occur after the
disk firmware upgrade.
2.
Reduce EVA maintenance overhead by setting the disk replacement timer to five minutes. Reset
the value to the default (60 seconds) once the upgrade process is complete. The longer setting
prevents triggering migration and revert processes as disks are upgraded.
3.
If you have not already done so, download the disk drive firmware file from the following website:
http://www.hp.com/support/evadiskfirmware
a.
Store the file to a known local directory. If you are running HP Command View EVA 9.x or
later, continue with step 4.
NOTE:
It is recommended that you use the default directory of C:\Program Files\
Hewlett-Packard\Sanworks\CodeLoad. If you use a different directory, you
will have to enter the complete path when identifying the location of the firmware files.
b.
If you are running HP Command View EVA 8.x or earlier, unzip the bundled image file and
place the files in a directory where HP Command View EVA resides (HP recommends that
you use the default directory noted in Step 3a.)
Continue with step 4.
4.
Open HP Command View EVA.
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide (XCS
6.220)
55