HP 6100 Software Manual page 41

Hp storageworks 4x00/6x00/8x00 enterprise virtual array updating product software guide (xcs 6.220) (5697-0459, october 2010)
Hide thumbs Also See for 6100:
Table of Contents

Advertisement

This procedure can be performed from the management server where HP Command View EVA is
installed, or from any host running the utility to communicate with the HP Command View EVA.
NOTE:
You will need the IP address or name of your management server to run the utility.
1.
Double-click the HP Storage Systems Scripting Utility desktop icon to open the utility. When
prompted, enter Manager (management server name or IP address), User name, and Password.
2.
Enter LS SYSTEM to display the arrays managed by the management server.
3.
Enter SELECT SYSTEM system name, where system name is the name of the storage system.
The storage system name is case sensitive. If there are spaces between the letters in the name,
quotes must enclose the name. For example, SELECT SYSTEM "Large EVA".
4.
Enter CAPTURE CONFIGURATION, specifying the full path and filename of the output files for
the configuration data.
The configuration data is stored in a series of one to five files, which are scripts. The file names
begin with the name you select, with the restore step appended. For example, if you specify a
file name of LargeEVA.txt, the resultant configuration files would be LargeEVA_Step1A.txt,
LargeEVA_Step1B, etc. Files which do not contain configuration information are not created
and therefore are not available to be restored.
The contents of the configuration files can be viewed with a text editor.
5.
Enter exit.
TIP:
When capturing the HP Command View EVA configuration, it is a best practice to specify the SAVE
ALL option. This helps to capture critical data such as the WWN, useful for rebuilding the array
configuration.
NOTE:
You cannot use the utility to restore a configuration that contains disk drives of different capacities.
You must manually restore that type of configuration. See the "Restoring an array configuration with
different disk sizes and types" section in the HP StorageWorks Storage System Scripting Utility
Reference for more information.
You can run the CAPTURE VALIDATE command for each of the files generated by the CAPTURE
CONFIGURATION command to determine if the file has been modified since the initial capture.
As a best practice, also use the following commands to collect configuration data:
LS DISK_GROUP FULL
LS HOST FULL
LS VDISK FULL
If applicable, use the following commands as well:
LS ISCSI_HOST FULL
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide (XCS