12
MOBILE OR MANUFACTURED HOME
INSTALLATION
• Installation MUST conform to the MANUFACTURED
HOME CONSTRUCTION & SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard is not
applicable, with AMERICAN NATIONAL STANDARD FOR
MOBILE HOME, ANSI/NFPA NO. 501B.
• The appliance MUST be vented to the outdoors with
the termination securely fastened to the mobile home
structure.
• The vent MUST NOT be terminated beneath a mobile or
manufactured home.
• The vent duct material MUST BE METAL.
• KIT 14-D346-33 MUST be used to attach the appliance
securely to the structure.
• The vent MUST NOT be connected to any other duct, vent, or
chimney.
• Do not use sheet metal screws or other fastening
devices which extend into the interior of the exhaust
vent.
• Provide an opening with a free area of at least 25 sq. in.or
introduction of outside air into the dryer room.

ALCOVE OR CLOSET INSTALLATION

13
0"
1"
• If your appliance is approved for installation in an
alcove or closet, it will be stated on a label on the
appliance back.
• The dryer MUST be vented to the outdoors. See the EXHAUST
INFORMATION section.
• Do not install this appliance with less than the minimum
clearances shown above.
• The closet should be vented to the outdoors to prevent gas
pocketing in case of a gas leak in the supply line.
• No other fuel-burning appliance shall be installed in the same
closet with the appliance.
CONSIDERATION MUST BE GIVEN TO
PROVIDE ADEQUATE CLEARANCES FOR
INSTALLATION AND SERVICE.
CAUTION:
DO NOT INSTALL THIS
APPLIANCE IN A CLOSET WITH A SOLID DOOR.
Installation Instructions
0"
DOOR VENTILATION OPENING (27"
MODELS)
A minimum of 120 square inches of opening, equally
divided at top and bottom, is required. Air openings are
required to be unobstructed when a door is installed.
A louvered door with equivalent air openings for the
full length of the door is acceptable.
27" Model
When louvers or registers are placed in door openings, the
free air openings of the louvers or registers must equal 120
square inches.
DOOR VENTILATION OPENING (24"
MODELS)
0"
A minimum of 72 square inches of opening is required. Air
openings are required to be unobstructed when a door is
installed. A louvered door with equivalent air openings for
1"
the full length of the door is acceptable.
24" Model
When louvers or registers are placed in door openings, the
free air openings of the louvers or registers must equal 72
square inches.
14
BATHROOM OR BEDROOM INSTALLATION
• The appliance MUST be vented to the outdoors. See
EXHAUST INFORMATION section 6 & 7.
• The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70 and NATIONAL FUEL GAS CODE,
ANSI Z223..
11
60 Sq. In.
60 Sq. In.
48 Sq. In.
24 Sq. In.