Sensor Monitoring For Problem Analysis - ACR Electronics NAUTICAST SOLAS AIS Installation Manual

Automatic identification system
Hide thumbs Also See for NAUTICAST SOLAS AIS:
Table of Contents

Advertisement

3.8.4

Sensor Monitoring for Problem Analysis

For specific information on a particular sensor, the NMEA input data can be monitored and is
listed on the AIS display.
N 1
*********** Sensor Settings ************
BaudRate Sensor1:< 4800>
BaudRate Sensor2:
BaudRate Sensor3: 38400
----------------------------------------
From the Sensor Configuration main screen one of the three sensor channels may be
selected by pressing 1, 2 or 3 or by using the cursor keys. By pressing the right cursor, the
monitoring process is started.
Complete NMEA sentence are shown. With Monitor 2 [M6] or Monitor 3 [M7] another sensor
channel can be selected.
Installation Manual
o
o
21' E
0
15' |1> N/A|2>0.00|3>0.10nm
Ignored:$HC---$-----$-----$-----
$-----$-----$-----$-----
1>Start Monitor>
4800
Ignored:$HC---$-----$-----$-----
$-----$-----$-----$-----
2>Start Monitor>
Ignored:$HC---$-----$-----$-----
$-----$-----$-----$-----
3>Start Monitor>
|
Save
| Default | Analyze | Back
*********** Sensor Settings ************
Monitoring Sensor Channel 2 PAGE 1/4
[08:26:48,000] $GPGLL,5330.1234,N,01001
.2345,E,141800.00,A,A
[08:26:48,328] $GPVTG,350.0,T,,M,10.0,N
,,K,A
[08:26:48,437] $VDVBW,11.00,01.00,A,12.
00,02.00,A,,V,,V
[08:26:48,547] $TIHDT,359.9,T
[08:26:48,656] $TIROT,0.0,A
[08:26:48,765] $GPGLL,5330.1234,N,01001
.2345,E,141800.00,A,A
[08:26:48,875] $GPVTG,350.0,T,,M,10.0,N
,,K,A
----------------------------------------
|Cfg CH2 |Monitor 1|Monitor 3|<-Back
CRC: auto
CRC: auto
CRC: auto
>
20