Ventilation Heights - Dometic RM2191 & RM2193 Installation & Operating Instructions Manual

For mobile home or recreational vehicle installation
Table of Contents

Advertisement

FIG. 1A

5. VENTILATION HEIGHTS

Refer to FIG 1 & FIG. 1A., Pages 2 & 3
Installation with upper side
Installation with upper side
Installation with upper side
Installation with upper side
Installation with upper side
vent and lower side vent
vent and lower side vent
vent and lower side vent
vent and lower side vent
vent and lower side vent
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
RM2191, RM2193
* This is the minimum height allowable. Where
possible, increase the minimum height by 11
inches (279mm) for a better air flow and cooling
performance.
Minimum Ventilation
Heights In:
INCHES
INCHES
MM
MM
INCHES
INCHES
INCHES
MM
MM
MM
*Min.
*Min.
*Min.
*Min.
*Min.
Max.
Max.
Max.
Max.
Max.
*Min.
*Min.
*Min.
*Min.
*Min.
Max.
Max.
Max.
Max.
Max.
20-5/8
31-5/8
524
803
6. CLEARANCES
Minimum clearances in inches to combustible materials
are:
G G G G G :
K K K K K :
L L L L L :
M M M M M :
N N N N N :
P: P: P: P: P:
NOTE: Clearance "M M M M M " is between the rearmost part of
NOTE
NOTE
NOTE
NOTE
the refrigerator and the wall behind the refrigerator.
NOTE: Clearance "N N N N N " is the distance between the
NOTE
NOTE
NOTE
NOTE
bottom of the lower vent to the top of upper side vent.
For ventilation height, refer to
Item 5. Ventilation Heights
Surfaces directly above and sides adjacent to the
Surfaces directly above and sides adjacent to the
Surfaces directly above and sides adjacent to the
Surfaces directly above and sides adjacent to the
Surfaces directly above and sides adjacent to the
flue outlet must be of, or covered with, fireproof
flue outlet must be of, or covered with, fireproof
flue outlet must be of, or covered with, fireproof
flue outlet must be of, or covered with, fireproof
flue outlet must be of, or covered with, fireproof
material. See FIG. 2.
material. See FIG. 2.
material. See FIG. 2.
material. See FIG. 2.
material. See FIG. 2.
NOTE
NOTE
NOTE: Clearance "P"
NOTE
NOTE
is 1/4 inch. This is the minimum height which can be
allowed over the condenser fins. Whenever possible,
increase this height by up to 11 inches; the more
ventilation you provide, the better the performance you
can expect from the refrigerator.
FIG. 2
FIG. 2
FIG. 2
FIG. 2
FIG. 2
3
Top
0"
Side
0"
Bottom
0"
Rear
1"
See NOTE
See NOTE
Section A. Installation,
. See FIG. 2.
"P" over top of unit condenser fins
"P"
"P"
"P"

Hide quick links: