Adding Fuel / Heating at Nominal Thermal Output

More fuel should be added to the fi re when the fl ames from
the previous burning off phase have just gone out.
Adding Fuel / Heating at Nominal Output
Procedure
Adjust secondary air
Set secondary air slider to
position 3-4
Add two logs weighing
Open fi re box door
approx. 1.9 kg in total.
Place logs with the end to
the front of fi re box. Only
add a single layer of fuel.
Close fi re box door
Tab. 2
34
8.

Emptying the Ash Drawer

As a safety precaution, please make sure that you only dispose
of ashes once they are cold.
The ash drawer contains the mineral components of the wood
(approx. 1%) as combustion residues.
Position of
Lift the fi re grate and tilt it towards the back (fi g. 3). The
Control Elements
furnace ash dump can then be removed (fi g. 4).