Thermo-magnetic motor protection

Autom. reset
Man. reset

Error messages

The thermic overload relay turns off in case of overloading. Because this relay
is installed on automatical reset, after a while the motors are switched back on
automatically.
Installation and type of overload relay
220V
Machine
Type
WE55/73/95
LR2D13109
WE110/132
LR2D13149
WE165
LR2D13149
380V
Machine
Type
WE55/73/95
LR2D13089
WE110/132/165
LR2D13109
When one of the following malfunctions occurs during a program, the central
display will communicate the appropriate error message at the end of the cycle.
E3 (Eprom)
The Eprom is wrong, replace it by another.
Remark :
For coin op machines, it is possible that a program number appears on the
right display in combination with E3.
This indicates a wrong price adjustment for this program. A coin value "0"
or bigger than "1000" was programmed.
Example : wrong price adjustment for program 5.
E4 (water level)
The appropriate water level was not reached after 15 minutes.
E5 (Heating)
The wash bath did not reach the required temperature after 80 minutes of
value
installation
4-6A
5A
7-10A
7A
7-10A
8A
value
installation
2,5A-4A
3A
4-6A
4A