Compaq 17XL260 - Presario - PIII 500 MHz Maintenance And Service Manual page 62

Presario 1700xl series
Table of Contents

Advertisement

Models: XL260, XL261, XL262, XL264, XL265, XL266, XL274, XL275, XL360, XL361,
XL362, XL363, XL364, XL365, XL366, XL367, XL368, XL369, XL370, XL371, XL372, XL373,
Error Code
Description
3206-xx
Audio System Internal Error
TouchPad/Pointing Device Interface Test Error Codes
Error Code
Description
8601-xx
Mouse test failed
8602-xx
Interface test failed
Error Code
Description
3301-xx
DVD or CD drive read test failed
3305-xx
DVD or CD drive seek test failed
6600-xx
ID test failed
6605-xx
Read test failed
6608-xx
Controller test failed
6623-xx
Random read test failed
Presario 1700 Series
XL374, XL375, XL376, XL377, and XL378
Audio Test Error Codes
DVD or CD Drive Test Error Codes
Recommended Action
Replace the system board and retest.
Recommended Action
The following steps apply to error codes
8601-xx through 8602-xx:
1. Replace the TouchPad and retest.
2. Replace the system board and retest.
Recommended Action
The following steps apply to error codes
3301-xx through 6623-xx:
1. Replace the DVD or CD and retest.
2. Verify that the speakers are
connected.
3. Verify that drivers are loaded and
properly installed.
4. Replace the DVD or CD drive and
retest.
5. Replace the system board and retest.