Compaq 17XL260 - Presario - PIII 500 MHz Maintenance And Service Manual page 55

Presario 1700xl series
Table of Contents

Advertisement

Models: XL260, XL261, XL262, XL264, XL265, XL266, XL274, XL275, XL360, XL361,
XL362, XL363, XL364, XL365, XL366, XL367, XL368, XL369, XL370, XL371, XL372, XL373,
Error Code
Description
101-xx
CPU test failed
102-xx
Coprocessor or Weitek Error
103-xx
DMA page registers test failed
104-xx
Interrupt controller master test
failed
105-xx
Port 61 error
106-xx
Keyboard controller self-test
failed
107-xx
CMOS RAM test failed
108-xx
CMOS interrupt test failed
109-xx
CMOS clock test failed
110-xx
Programmable timer load data
test failed
113-xx
Protected mode test failed
114-01
Speaker test failed
200-xx
Memory machine ID test failed
202-xx
Memory system ROM checksum
failed
203-xx
Write/Read test failed
204-xx
Address test failed
211-xx
Random pattern test failed
214-xx
Noise test failed
215-xx
Random address test failed
Presario 1700 Series
XL374, XL375, XL376, XL377, and XL378
Processor Test Error Codes
Recommended Action
Replace the processor and retest.
1. Run the Configuration and Diagnostics
Utilities.
2. Replace the processor board and
retest.
The following applies to error codes
103-xx through 114-01:
Replace the system board and retest.
1. Check system configuration.
2. Verify cable connections to speaker.
3. Replace the system board and retest.
The following steps apply to error codes
200-xx and 202-xx:
1. Flash the system ROM and retest.
2. Replace the system board and retest.
The following steps apply to error codes
203-xx through 215-xx:
1. Remove the memory module and
retest.
2. Install a new memory module and
retest.