Turning on, off, and restarting computers out of band

To unconfigure Intel AMT devices
1
In the Symantec Management Console, on the Manage menu, click Jobs and
Tasks.
2
In the left pane, click System Jobs and Tasks > Real-Time Console
Infrastructure > Update Intel AMT Settings.
3
Check Unconfigure Intel AMT and select the unconfiguration method and
the Intel AMT mode to set after unconfiguration.
Choose from the following options:
Partial
Removes all Intel AMT settings except for administrative user credentials
and PID-PPS pairs. After partial unconfiguration is complete, the Intel AMT
client computer starts sending configuration requests to the setup and
configuration server (Intel SCS). The computer is not available for
management through the Intel AMT interface until it is configured again
by Intel SCS.
Full
Removes all settings from the Intel AMT device. You must initialize, set up,
and configure the device again.
If you click this option, you can also select a Small Business or Enterprise
configuration model to set after unconfiguration is complete.
For more information on the Intel AMT initialization, setup, and configuration,
see the Out of Band Management Component Implementation Guide.
4
Click Save changes.
5
Run the task one time or on a schedule.
For more information, view topics about running and scheduling tasks in the
Symantec Management Platform Help.
Choose a connection profile that is configured with correct Intel AMT
credentials.
For more information, view topics about connection profiles in the Symantec
Management Platform Help
You can manage the power state of client computers remotely using WMI, Intel
AMT, ASF, and DASH technologies.
For example, you can turn on computers before delivering a software package.
Or you can turn off the computers that have sent critical SNMP alerts to
Notification Server.
Using Real-Time Console Infrastructure