Powering the Axis network camera, housing and heater
Note - this installation requires 2 x 230V power cables and 2 x 12V cables (not supplied).
1. Pull the mains power cable through the gland (5) to the housing connector (J4).
2. Connect a 230V cable to the housing connector (J3) and pull through the gland (6).
Connect to the external power supply connector (A).
3. Connect a 12V power cable to the connector (B) in the power supply, pull the 12V cable
through the gland (7) in the housing and connect to the 12V connector (J1).
4. Connect a 12V cable from the connector (J1) to the green connector on the camera (8).
Important! Ensure that the (+) and (-) wires are connected according to the camera
model installed in the housing (see images above).
5. To connect the heater, follow the supplied instructions and connect the cable to the
connector (J2) in the housing.
6. Proceed with the installation according to the instructions in the Installation Guide
supplied with the camera.
Wiring diagram
Installation Instructions
PCB
Power supply
230V AC in
PCB
Housing
12V DC
to camera
230V AC
out
230V AC
in
Heater 230V AC