Installation Wiring Diagram
Strip insulation
15/32 so that
wire strands are
flush with end of
eyelet, 2 places
Chassis
Ground
NOTE: Minimum wire size on charger
#8 AWG.
output and ground is
gauge wire may cause overheating of
terminal. Use GS 7-13 eyelet over wire
to simplify insertion of wire into terminal
strip and to improve connection
CONNECTION
A.C.
COM
BAT 1 / BAT 2
BATTERY SAVER
IMPORTANT: Wire size is for a maximum length of 10 feet. If longer, larger wiring is required.
10/27/2004
Auto Charge 4000
REMOTE DISPLAY
4
3
2
1
POSITIVE
COM
BAT 1
BAT 2
Chassis
Ground
Smaller
DEFINITION
120 VOLTS A.C.
GROUND LINE
POSITIVE CHARGING LEAD VEHICLE BATTERY 1
POSITIVE OUTPUT
POWER
BATTERY SAVER
OVERLOAD
BATTERY
SAVER
Chassis
Ground
Wire Chart
Indicator
A.C.
POWER
Battery Saver Loads
(5 amps max.).
When the charger
is disconnected from
120 volts AC the
Battery Saver loads
automatically are
connected to battery #1.
Accessories
WIRE SIZE
14 AWG
8 AWG
8 AWG
14 AWG