Performance
Data Sheet
Models Number 5231JA2002B-S
Use with replacement
cartridge
5231JA2002B
This system has been tested according
to NSF/ANSI
Standards
42 for the reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water
entering
the system was reduced
to a concentration
less than or equal
to the permissible
limit for water
leaving the system as specified
in NSF/ANSl
42.
i
System
tested
and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor
and Nomina!
Particulate
Class
Ill.
1
Capacity:
500 gal (1,892
L)
Substance
Average
Influent Challenge
Avg. Product
Average
NSF % reduction req.
Infiuent
Concentration.
Units
Water
%
or Max. permissible
product
Concentration
apply to each row
Concentration
Reduction
water concentration
Nominal Particulate
Class
I Particle
size:
>0.5
to<lum
24,333
At
least
10,000
particles/ml
915
96
>_ 85%
Chlorine taste and odor
> 50%
ClassIII
1.9
2.0 mg/L +_10%
0.07
96.4
_
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Application
Guidelines/Water
Supply Parameters
Service flow
0.5 gpm ( 1.89 ipm)
Water pressure
20- 125 psi (138- 862 kPa)
Water temperature
33°F - 100° F (0.6°C - 38°C)
[] WARNING
Toreducethe risk associatedwith ingestionof contaminantsdueto use with
waterthat is microbiologicallyunsafeor of unknownquality.
Do not use with waterthat is microbiologicallyunsafeor of unknown quality
without adequatedisinfectionbeforeor afterthe system.
Systems must be installed and operated in accordance with manufacturer's
recommended procedures and guidelines.
Warranty: SeeWarranty Card for Details.
[]CAUTION
TOreduce the risk of property damagedue to water leakage:
• Read andfollow Useinstructions beforeinstallation and use of this system.
, Installon COLDwater lines only,
• Comply with al! state and local plumbing codes.
• Install a pressure limiting device and water hammer arrester for inlet water pressures
exceeding 80 psi (552 kPa).Referto Uniform Plumbing Code, Sections608.2 and 609.10.
° Neverinstall or operatewhere inlet water pressure may exceed 120 psi (827 kPa).
• Protectfilter from freezing. Removefilter in temperaturesbelow 33°F (0,6°C).
o Replacecartridge at specified service interval. Cartridge MUSTbe replaced at leastevery
12 months.
To purchasea replacement f ilter,visit yourlocalSearsstoreor call1-800-4-MYHOME®.
Visit us on theweb at www.sears.com
Distributedby:
Sears BrandManagementCorporation
3333BeverlyRoad
HoffmanEstates,IL 60179
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.5881

Table of Contents