CONTROLS & CONNECTIONS
Clock. This button sets the DigiMax D8 to External digital sync or sets the Internal sample rate.
Press the Clock button once to set the clock to internal sync and your sample rate to 44.1 kHz.
o
This will make the DigiMax D8 the Master clock of your system. It will be sending out word clock
via the ADAT output.
o
Press the Clock button twice to set the clock to internal sync and your sample rate to 48 kHz.
Press the Clock button three times to set the clock to external sync. This will make the DigiMax
o
D8 look for a master clock via the BNC word clock input. Your sample rate will automatically
change to match that of your master clock.
Please note: If you are using the DigiMax D8 to record into a DAW application like Logic, ProTools,
Cubase or Sonar, you must set the sample rate inside your host application to match the sample rate
you set on your master clock generator.