Sample Hook Up Diagrams; Using The Digimax D8 With Protools - PRESONUS DIGIMAX D8 - V 1.0 User Manual

8 channel preamplifier with 24-bit/48 khz adat out
Table of Contents

Advertisement

3.3 SAMPLE HOOK UP DIAGRAMS

3.3.1 Using the DigiMax D8 with ProTools

The DigiMax D8 is the perfect solutions to expand your ADAT compatible Digidesign interface.
For example: To set up a Digi 003 with ProTools LE software:
1. Plug in an ADAT cable from the optical output of the DigiMax D8 to the optical input of the Digi 003
2. Plug in a BNC word clock cable from the Digi 003 BNC word clock output to the BNC input of the
DigiMax D8
3. Push the 'clock' button on the DigiMax D8 three times, until the yellow "external" LED is lit.
Please note: When using Digidesign interfaces that do not have word clock output, you will need to set the
DigiMax D8 as the master clock of the system. Push the 'clock' button to the internal setting you prefer (48
kHz or 44.1 kHz). In ProTools, go to Setups>Hardware setup. Select "RCA = S/PDIF, Optical = ADAT"
and set the clock to "ADAT".
OPERATION
Digi003, ProTools, and Digidesign are trademarks of Avid™
13
| PreSonus 2007

Advertisement