Download Print this page
Dacor DHW301 Planning Manual
Dacor DHW301 Planning Manual

Dacor DHW301 Planning Manual

30”, 36”, 42” and 48” wide wall mount chimney hoods

Advertisement

Document # PG07-001
All tolerances: ±1/16" (±1.6 mm), -0, unless otherwise stated
Chimney
24"
DHW SErIES ovErALL DImENSIoNS
600 CFM* (1200 CFM* for units with 2 blowers)
Blower
with electronic speed control
Blower speeds
4
Lights
12 Vac, 20 Watt halogen
Filters
Baffle type, dishwasher safe
Exhaust
8 inch
Finish
430 stainless steel
Total connected
120 Vac, 60 Hz.
load
(see table at right for current rating)
Circuit
120 Vac, 15 Amp. grounded, dedicated 3-wire
requirements
circuit (hot, neutral, ground)
* At zero inches static pressure
GENErAL SPEcIfIcAtIoNS
DHW301
Blowers
1
Lights
2
Filters
1
Maximum
3.4 Amp.
current draw
moDEL SPEcIfIc SPEcIfIcAtIoNS
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
DHW Hoods
30", 36", 42" and 48" Wide
Wall mount chimney Hoods
11 3/4"
15"
5 3/4"
30" - 36" - 42" - 48"
* 18" 1/4 on 48 inch model (DHW482)
MODEL NUMBER
DHW361
DHW421
1
1
2
3
1
1
3.4 Amp.
3.6 Amp.
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
accompanying installation instructions.
DO NOT install an additional in-line or external blower to
increase the length of the duct run. Even small differences
between blower air flow rates can greatly reduce the air draw
of the hood.
Chimney can accommodate up to 10" round duct work
Unit can be installed to exhaust through the ceiling or through the rear
wall (see diagram below).
IMPORTANT: The minimum installed distance from the hood to the cooking
surface must be no less than 30 inches. The minimum specified distance
may be higher for the particular range or cooktop in use. Check the
manufacturers specifications for the cooktop or range.
Maximum Duct Length
The maximum straight duct length for the hood is 50 feet. To determine the
actual maximum duct run, subtract the equivalent length of each elbow,
transition and cap from 50 feet. See the Duct Planning Guide or the
installation instructions for more details.
DHW482
2
4
2
6.8 Amp.
www.Dacor.com
Revised 06/24/10 Page 1/1