8. Insert lamp through hole until lamp cannot be inserted any further. (See
Figure 17)
9. Swing swivel bracket over end of lamp and hand-tighten the wing nut on
stud. (See Figure 18)
10. Plug ballast plug into end of lamp. (See Figure 19)
11. Replace cover on unit. Tighten side screws. (See Figure 20)
12. Plug the power cord into a standard electrical outlet.
NOTE: Seal the joints and seams of the plenum near the mounting location to reduce
any direct viewing of light. (See Figure 1)
13. Flip switch on box to the 'ON' position. (Light on switch should be on indicating power.)
14. Look through view port in the box cover to be sure lamp is working. You should see a blue glow. (The view port
is covered with a plastic lens that blocks the UVC rays.)
15. If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical support at 1-252-
522-3031 for further assistance.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your
hands.