Equipment Data - Dimplex LA 10MR Installation And Operating Instructions Manual

Air-to-water heat pump for outdoor installation
Table of Contents

Advertisement

Equipment Data

EQUIPMENT DATA for air-to-water heat pumps for heating
TYPE AND COMMERCIAL DESCRIPTION
1
MODEL
2
2.1
Type
2.2
Enclosure type acc. to EN 60 529 for compact unit and/or heating element
2.3
Installation site
PERFORMANCE DATA
3
3.1
Operating temperature limits:
Heating water supply / return
Cooling, flow
Air (heating)
Air (cooling)
3.2
Heating capacity / coeff. of perform. at A7 / W35
3.3
Cooling capacity / coeff. of perform. at A35 / W18
3.4
Sound power level
3.5
Sound pressure level at 10 m distance (discharge side)
3.6
Heating water flow rate
3.7
Free pressure, heating circulating pump (max. stage)
3.8
Refrigerant; total charge weight
3.9
Rating electric heating element (back-up heater) max.
DIMENSIONS; CONNECTIONS AND WEIGHT
4
4.1
Equipment dimensions
4.2
Equipment connections for heating
4.3
Weight of transport unit(s) incl. packaging
ELECTRICAL CONNECTION
5
5.1
Nominal voltage; fusing
5.2
Fuse protection, electric heating element (only 230V units)
5.3
Nominal power consumption 1) A2 W35
5.4
Starting current with soft starter
Nominal current A2 W35 / cos ϕ
5.5
COMPLIES WITH EUROPEAN SAFETY REGULATIONS
6
OTHER DESIGN CHARACTERISTICS
7
7.1
Defrosting
Defrost type
Defrost pan available
7.2
Heating water inside unit protected against freezing
7.3
Performance settings
1)
These data characterize the size and performance of the system. For economic and energetic
considerations, additional factors such as defrosting behaviour, bivalence point and control need to be taken
into account. Abbreviations have the following meaning: e.g. A7 / W35: outside temperature 7 °C and
heating water supply temperature 35 °C.
2)
The heating circulating pump and the controller of the heat pump must be on standby at all times.
3)
See EC Declaration of Conformity
4)
For the electr. connection of the electric heating element, a separate load line with its own fuse protection is required.
Subject to change without notice
°C / °C
°C
°C
°C
1)
kW / ---
at A7 / W45
1)
kW / ---
kW / ---
at A35 / W7
kW / ---
dB(A)
dB(A)
m³/h
Pa
type / kg
kW
H x W x L cm
inch
kg
V / A
A
kW
A
A / ---
APPENDIX: 12.2 EQUIPMENT DATA
LA06MRN
LA08MRN
reversible
reversible
IP 24
IP 24
outdoors
outdoors
max.60/min.18
max.60/min.18
+7 to +20
+7 to +20
-20 to +35
-20 to +35
+15 to +45
+15 to +45
6.1 / 3.3
7.4 / 3.3
6.1 / 2.7
7.3 / 2.7
7.9 / 3.2
9.4 / 3.3
6.4 / 2.7
7.7 / 2.9
70
71
45
46
1.1
1.3
34800
35600
R407C / 1.5
R407C / 2.3
6
6
86 x 127 x 67
86 x 127 x 67
G 1'' external
G 1'' external
159
165
230 / 20
230 / 20
4)
4)
30
30
1.9
2.3
26
32
10.3
12.5
3)
3)
automatic
automatic
cycle reversal
cycle reversal
yes (heated)
yes (heated)
yes 2)
yes 2)
1
1
Issued: 02.03.2006
13
LA10MRN
LA12TRN
LA16TRN
reversible
reversible
reversible
IP 24
IP 24
IP 24
outdoors
outdoors
outdoors
max.60/min.18
max.60/min.18
max.60/min.18
+7 to +20
+7 to +20
+7 to +20
-20 to +35
-20 to +35
-20 to +35
+15 to +45
+15 to +45
+15 to +40
8.5 / 3.4
11.9 / 3.3
15.3 / 3.3
8.4 / 2.8
11.6 / 2.7
14.9 / 2.8
11.1 / 3.3
15.8 / 3.3
18.5 / 3.3
9.0 / 2.9
13.6 / 3.0
16.1 / 3.0
71
72
72
46
47
47
1.5
1.7
1.9
33800
32700
58900
R407C / 2.3
R407C / 3.4
R407C / 3.7
6
6
6
86 x 127 x 67
86 x 127 x 67
86 x 127 x 67
G 1'' external
G 1'' external
G 1'' external
170
185
196
230 / 25
400 / 20
400 / 25
4)
-
-
30
2.5
3.6
4.6
38
26
27
13.6
6.5
8.3
3)
3)
3)
automatic
automatic
automatic
cycle reversal
cycle reversal
cycle reversal
yes (heated)
yes (heated)
yes (heated)
yes 2)
yes 2)
yes 2)
1
1
1