NOTES:

4 inches of STRAIGHT VERTICAL Burner line must be available between the gas valve (thermostat) and
the burner assembly for proper installation of Pilot Saver kit.
These instructions take the place of the Gas Solenoid Valve mounting instructions in VP-2/3
and WHK-2 manual. The 3/8" to 1/2" adapter fittings in Safety Controls Kit are not required.
IMPORTANT: Shut off gas supply before attempting the following procedure.
Step 1.
Remove the burner line, pilot line and thermocouple from gas valve (thermostat).
Step 2.
Disconnect burner assembly from water heater with burner line still attached.
Step 3.
Remove 3 inches of vertical burner line between flared end and burner assembly. Remove any burrs on
burner line tubing.
Step 4.
Apply pipe thread sealant on 3/8" threaded stem on Compression Fittings.
Step 5.
Screw 3/8" threaded stem on Compression Fittings into Solenoid. Tighten Compression Fittings with
wrench.
NOTE:
Indicator Arrow on Solenoid must face the direction of gas flow to burner assembly.
Step 6.
Insert burner line from gas valve (thermostat) into compression side of Compression Fitting. NOTE: Before
tightening compression fitting on burner line, make sure male end which screws into gas valve is orientated
properly and is between compression fitting and flared end of burner tubing. Tighten with wrench.
Step 7.
Insert burner line from burner assembly into compression side of Compression Fitting. Tighten with wrench.
Step 8.
Install burner assembly into water heater.
Step 9.
Reconnect burner line, pilot line, and thermocouple to gas valve (thermostat).
NOTE:
All gas piping shall be tested and inspected in accordance with NFPA 54, ANSI Z223.1, part 4.
This modification is acceptable per the American Gas Association (AGA) Report No: 916-1A.
P/N: 8504028
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
PILOT SAVER (950-2061) INSTRUCTIONS
NEW VP-2/3, WHK-2 INSTALLATION
INSTALLATION AFTER PILOT SAVER INSTALLED
©1994 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED

TOOLS REQUIRED

Pipe Cutter
Adjustable Wrench
Pipe Thread Sealant
REV. 2, 9/95

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 950-2061 PILOT SAVER KIT 8504028 REV 2 0995 and is the answer not in the manual?

Questions and answers

Summary of Contents for TJERNLUND 950-2061 PILOT SAVER KIT 8504028 REV 2 0995

  • Page 1 All gas piping shall be tested and inspected in accordance with NFPA 54, ANSI Z223.1, part 4. This modification is acceptable per the American Gas Association (AGA) Report No: 916-1A. INSTALLATION AFTER PILOT SAVER INSTALLED P/N: 8504028 ©1994 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED REV. 2, 9/95...
  • Page 2 PILOT SAVER (950-2061) INSTRUCTIONS EXISTING VP-2/3, WHK-2 INSTALLATION NOTES: 4 inches of STRAIGHT VERTICAL Burner line must be available between the gas valve (thermostat) and the burner assembly for proper installation of Pilot Saver kit. These instructions take the place of the Gas Solenoid Valve mounting instructions in VP-2/3 and WHK-2 manual.

This manual is also suitable for:

Pilot saver 950-2061Vp-2Vp-3Whk-2

Table of Contents