2-11: VCO FREERUN
1.
Receive an 80dB monoscope pattern.
2.
Connect the digital voltmeter between the TP201 and
the Ground.
3.
Adjust the L205 until the digital voltmeter is 3.1
2-12: SEPARATION 1, 2
1.
Receive the stereo broadcasting signal.
2.
Connect the AC voltmeter to CP351 through stereo filter
(L=400Hz, R=2KHz).
3.
Activate the adjustment mode display of Fig. 2-1 and
press the channel button (7) on the remote control.
The Fig. 2-9 appears on the display.
4.
Press the channel button (2) on the remote control.
5.
Press the VOL. UP/DOWN button on the remote control
until the output of L-CH and R-CH become minimum.
6.
Press the CH UP button once to set to "SEPARATION
2" mode.
7.
Press the VOL. UP/DOWN button on the remote control
until the output of L-CH and R-CH become minimum.
1. LEVEL ADJ
2. SEPARATION 1
3. SEPARATION 2
4.
5.
6.
7.
8.
ELECTRICAL ADJUSTMENTS
0.05V.
0. RETURN
Fig. 2-9
D1-3