SERVICING NOTICES ON CHECKING 1. KEEP THE NOTICES 6. AVOID AN X-RAY As for the places which need special attentions, Safety is secured against an X-ray by consider- they are indicated with the labels or seals on the ing about the cathode-ray tube and the high cabinet, chassis and parts.
CONTENTS SPECIFICATIONS ............................ COVER SERVICING NOTICES ON CHECKING ....................A1-1 HOW TO ORDER PARTS ........................A1-1 IMPORTANT ............................A1-1 CONTENTS .............................. A2-1 GENERAL SPECIFICATIONS ........................A3-1~A3-4 DISASSEMBLY INSTRUCTIONS 1. REMOVAL OF ANODE CAP......................2. REMOVAL OF DEFLECTION YOKE ................... SERVICE MODE LIST ..........................CONFIRMATION OF USING HOURS.......................
G E N E R A L S P E C I F I C A T I O N S G-1.Outline of the Product inch( 626 mmV):Measured diagonally Color CRT 100 degree deflection G-2.Broadcasting System System G-3.Color System NTSC SECAM or Monochrome signal G-4.NTSC Playback(PAL 60Hz) G-5.NTSC 3.58+4.43/PAL60Hz...
Page 5
G E N E R A L S P E C I F I C A T I O N S G-17. P rotector: Power Fuse G-18.Regulation Safety NEMKO FEMKO DEMKO IEC65 SEMKO HOMOLO SABS SISIR AS3159 DENTORI GOST NONE Radiation SABA HOMOLO...
Page 6
G E N E R A L S P E C I F I C A T I O N S G-26.OSD Language OSD Language Setting Not Applicable G-27.Speaker 1.5 x 2.7 inches Imp. ohm x Max 2.5 + 2.5 W (Typical) 10% 2.0 + 2.0 W (Typical) G-28.EXT Speaker G-29.Carton...
Page 7
G E N E R A L S P E C I F I C A T I O N S G-32.Switch Front Power(Tact) Channel Up/Reset Volume Up/Set Up System Select Channel Down/Enter Volume Down/Set Down Main Power S W Sub Power Menu:Vol UP + Vol Down Rear...
DISASSEMBLY INSTRUCTIONS 3. After one side is removed, pull in the opposite direction to 1. REMOVAL OF ANODE CAP remove the other. Read the following NOTED items before starting work. NOTE After turning the power off there might still be a potential Take care not to damage the Rubber Cap.
DISASSEMBLY INSTRUCTIONS 4. Insert one end of the Anode Support into the anode button, then the other as shown in Fig. 1-5. Support Fig. 1-5 Confirm that the Support is securely connected. Put on the Rubber Cap without moving any parts. 2.
SERVICE MODE LIST This unit provided with the following SERVICE MODES so you can repair, examine and adjust easily. Set Key Remocon Key Operations Releasing of V-CHIP PASSWORD. VOL. (-) MIN Initialization of the factory. VOL. (-) MIN NOTE: Do not use this for the normal servicing. POWER ON total hours is displayed on the screen.
ELECTRICAL ADJUSTMENTS 1. BEFORE MAKING ELECTRICAL 1. RF AGC DELAY ADJUSTMENTS 2. VIDEO LEVEL Read and perform these adjustments when repairing the 3. FM LEVEL circuits or replacing electrical parts or PCB assemblies. 4. OSD H 5. CUT OFF CAUTION 6.
Page 12
ELECTRICAL ADJUSTMENTS 2-5: SUB TINT/SUB COLOR 2-8: VERTICAL SIZE Receive the color bar pattern. Receive the crosshatch pattern. Connect the synchro scope to pin 1 of CP101 and the Using the remote control, set the brightness and pin 6 (GND) of CP101. contrast to normal position.
Page 13
ELECTRICAL ADJUSTMENTS 2-11: VCO FREERUN Receive an 80dB monoscope pattern. Connect the digital voltmeter between the TP201 and the Ground. Adjust the L205 until the digital voltmeter is 3.1 0.05V. 2-12: SEPARATION 1, 2 Receive the stereo broadcasting signal. Connect the AC voltmeter to CP351 through stereo filter (L=400Hz, R=2KHz).
Page 14
ELECTRICAL ADJUSTMENTS PURITY AND CONVERGENCE 3-3: STATIC CONVERGENCE ADJUSTMENTS NOTE Adjust after performing adjustments in section 3-2. NOTE Receive the crosshatch pattern from the color bar Turn the unit on and let it warm up for at least 30 generator. minutes before performing the following adjustments.
BLOCK DIAGRAM IC351 AN5277 SPEAKER SOUND CHROMA TU001 SPEAKER IC201 LA76814M-MPB AUDIO IF/RF AGC SOUND_R SOUND_L CH. DOWN DRIVE CF201 Q604, Q605 SAW FILTER VIDEO VIDEO MICON VIDEO VOL. DOWN BUFFER IC101 OEC3041A Q801 POWER TV MUTE RED OUT TONE CONTROL IC705 M62420SP RGB OUT Q803...
Page 22
POWER SCHEMATIC DIAGRAM CAUTION: FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE SAME TYPE 6.3A 125V (F501) FUSE. ATTENTION: POUR UNE PROTECTION CONTINUE LES RISQUES 6.3A 125V D’INCEIE N’UTILISER QUE DES FUSIBLE DE MEME TYPE 6.3A 125V (F501). DEGAUSS COIL CP502 L502...
Page 23
SOUND SCHEMATIC DIAGRAM FROM MICON/TUNER I2C_SDA I2C_SCL AUDIO_MUTE L704 FROM CHROMA 22uH TU_AUDIO_OUT TP701 P.CON+9V TU_AUDIO_OUT R752 C775 1.8K 0.033 M C770 C777 0.022 0.47 1.8K TONE 136K AMP1 I2C BUS INTERFACE SIMAMP1 VOLAMP1 6.5K 6.5K 6.5K VOLAMP2 R729 C748 CONTROL SOUND_R SIMAMP2...