Download Print this page
HIKVISION DS-KH9510-WTE1 User Manual
Hide thumbs Also See for DS-KH9510-WTE1:

Advertisement

Quick Links

DS-KH9510-WTE1
Android Indoor Station
1
E N G L I S H
Diagram References
Appearance
1
1
Screen
5
Alarm Terminals
9
Loudspeaker
Note: The appearance of the device varies according to different models. Refers to the actual device for detailed
information.
Terminal
2
AIN1: Alarm Input 1
AIN2: Alarm Input 2
AIN3: Alarm Input 3
AIN4: Alarm Input 4
NO1/NO2: Normally Open
COM1/COM2: Common Interface
RS485-/RS485+: RS-485 Communication Interface
Note: For Wiring description, refers to the User Manual.
Installation
3
Mounting Accessories
The wall mounting plate and the gang box are required to install the indoor station onto the wall.
There are 2 sizes of the gang boxes adapted to the device.
Size 1: 75 mm (width) × 75 mm (length) × 46 mm (depth).
Size 2: 55 mm (width) × 101 mm (length) × 38.5 mm (depth).
Before you begin:
Make sure the device in the package is in good condition and all the assembly parts are included.
The power supply of the indoor station is 12 VDC. Make sure your power supply matches your indoor
station.
Make sure all related equipments are power-off during the installation.
Check the product specification for the installation environment.
Wall Mounting with Gang Box
3
1. Cave a hole in the wall.
Note: The suggested dimension of the installation hole should be larger than the gang box.
2. Insert a gang box to the hole chiseled on the wall.
3. Fix the wall mounting plate to the gang box with 2 screws.
Notes:
If you install the device with a gang box (75 mm (width) × 75 mm (length) × 46 mm (depth)), the upper and lower holes
will be applies.
If you install the device with a gang box (55 mm (width) × 101 mm (length) × 38.5 mm (depth)), the upper and lower
holes will be applies.
4. Hook the indoor station to the wall mounting plate tightly by inserting the plate hooks into the slots on
the rear panel of the indoor station, during which the lock catch will be locked automatically.
Getting Started
4
Activate Indoor Station
1
You are required to activate the device first by setting a strong password before
you can use the device.
6
1. Power on the device. It will enter the activation page automatically.
2. Create a password and confirm it.
3. Tap OK to activate the indoor station.
Quick Configuration
2
1. Choose Language and tap Next.
2. Set network parameters and tap Next.
- Edit Local IP, Subnet Mask and Gateway parameters.
- Enable DHCP, the device will get network parameters automatically.
3. Configure the indoor station and tap Next.
a. Select Indoor Station Type.
b. Edit Floor and Room No.
4. Linked related devices and tap Next. If the device and the indoor station are in the
same LAN, the device will be displayed in the list. Tap the device or enter the serial No.
to link.
a. Tap the door station in the list to link.
b. Tap the settings icon to pop up the Network Settings page.
2
c. Edit the network parameters of the door station manually or enable DHCP to get
the network parameters automatically.
d. Optional: Enable Synchronize Language to synchronize the Language of door
3
station with indoor station.
e. Tap OK to save the settings.
5. Tap Finish to save the settings.
The power supply must conform to LPS. The recommended adaptor models and
manufacturers are shown as below. Use the attached adaptor, and do not change the
adaptor randomly.
Model
MSA-C1500IC12.0 -18P -US
TS-A018-120015AD
Refer to Video Intercom Network Indoor Station Configuration Guide (scan the QR code) for details.
RS485-
Refer to Video Intercom Network Indoor Station Operation Guide (scan the QR code) for details.
RS485+
COM2
NO2
COM1
NO1
Rear Panel (without Interface)
Note: If you use the gang box (55 mm (width) × 101 mm (length) × 38.5 mm (de
RS485/Relay Interface
Note: If you use the gang box (75 mm (width) × 75 mm (length) × 46 mm
2
Microphone
6
RS-485/Relay Interface
10
Reserved
AIN5: Alarm Input 5
AIN6: Alarm Input 6
AIN7: Alarm Input 7
AIN8: Alarm Input 8
GND: Grounding
3
4
122
92
7 8
Lock Catch
Current
1.5 A
Lock Catch
1.5 A
Lock Catch
Lock Catch
Rear Panel (without Interface)
UD19191B
3
Unlock Button
7
Debugging Port
11
TAMPER
5
12
Lock Catch
Manufacturer
MOSO POWER SUPPLY TECHNOLOGY CO.,LTD
Lock Catch
SHENZHEN TRANSIN TECHNOLOGIES CO.,LTD
Lock Catch
Lock Catch
Alarm Terminals
4
Power Supply Interface
8
microUSB Interface
12
Network Interface
1.5
Unit:mm
AIN8
AIN7
Hook
AIN6
AIN5
AIN4
AIN3
AIN2
Hook
AIN1
GND
GND
Screw
1
2
9
10
11
Standard
PG
PG
Hook
Ho
Hook
Wall Moun
Screw

Advertisement

loading
Need help?

Need help?

Do you have a question about the DS-KH9510-WTE1 and is the answer not in the manual?

Questions and answers

Summary of Contents for HIKVISION DS-KH9510-WTE1

  • Page 1 DS-KH9510-WTE1 Android Indoor Station UD19191B E N G L I S H Diagram References Appearance Screen Microphone Unlock Button Power Supply Interface Alarm Terminals RS-485/Relay Interface Debugging Port microUSB Interface Loudspeaker Reserved TAMPER Network Interface Note: The appearance of the device varies according to different models. Refers to the actual device for detailed information.
  • Page 2 Note: If you use the gang box (75 mm (width) × 75 mm (length) × 46 mm (depth)) to install, you should set the screws to up and down screw holes. Hook Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China ounting Plate...
  • Page 3 E N G L I S H Diagram References Appearance Screen Microphone Unlock Button Power Supply Interface Alarm Terminals RS-485/Relay Interface Debugging Port microUSB Interface Loudspeaker Reserved TAMPER Network Interface Note: The appearance of the device varies according to different models. Refers to the actual device for detailed information.
  • Page 4 Please use this Manual with the guidance and assistance of professionals trained in supporting the Product. and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.