  • Page 1 ™ ™ Origin200 and Origin Vault Installation Instructions Document Number 108-0153-002...
  • Page 2 © 1997, Silicon Graphics, Inc.— All Rights Reserved The contents of this document may not be copied or duplicated in any form, in whole or in part, without the prior written permission of Silicon Graphics, Inc. RESTRICTED RIGHTS LEGEND Use, duplication, or disclosure of the technical data contained in this document by the Government is subject to restrictions as set forth in subdivision (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 52.227-7013 and/or in similar or...
  • Page 3 This device has several governmental and third-party approvals, licenses, and permits. Do not modify this product in any way that is not expressly approved by Silicon Graphics, Inc. If you do, the customer may lose these approvals and their governmental agency’s permission to operate this device.
  • Page 5 About This Guide...................xix Audience ...................... xix Structure of This Guide ................xix Additional Documentation................. xx Origin200: Overview and Theory of Operations .........1-1 Installation Options: Tower and Rackmounting ........1-4 Multimodule Grounding and Site Preparation ........1-4 Feature Summary..................1-5 Logic Carrier ....................1-6 1.4.1...
  • Page 6 Main Power Switch and Power Button..........2-10 Configurations and Cabling for the 3.5-Inch Drive Controller ..2-11 Technical Specifications ................2-13 Setting Up an Origin200 System ..............3-1 Choosing a Location For the Server ............3-1 3.1.1 Providing Correct Electrical Grounding (Earthing)..... 3-2 3.1.2...
  • Page 7 4.13 Verifying Drive Installation..............4-44 4.14 Configuring Drives ................... 4-45 Installing an Origin200 System in a Rack ...........5-1 Overview ...................... 5-2 Installing the Mounting Hardware on the Chassis........ 5-3 Installing the Rackmounting Shelf ............5-5 Installing a Chassis In the Rack ..............5-6 Removing a Server From an Equipment Rack........
  • Page 8 Setting Up and Starting the Terminal Emulator..........6-15 6.5.1.3 Logging In To the Server ........6-16 6.5.2 Using a A Silicon Graphics Workstation As the System Console ............... 6-17 6.5.2.1 Obtaining the Correct Serial Cable..... 6-17 6.5.2.2 Checking for the Correct Software ..... 6-18 6.5.2.3...
  • Page 9 Installing a 3.5-Inch Peripheral ..........9-14 9.2.4 Removing a 3.5-Inch Peripheral..........9-17 Verifying That A Drive Is Installed Correctly ........9-20 Using Drives In the Origin200 ..............9-20 Attaching Serial Devices ................9-22 9.5.1 Attaching Serial Cables ............9-23 9.5.2 Attaching Serial (ASCII) Terminals........
  • Page 10 Installing a New Differential/Single-Ended Converter Board ..............11-24 11.9 Checking and Replacing the Origin200 Power Supply ..... 11-25 11.9.1 Installing a New Power Supply In the Origin200 Server 11-27 11.10 Checking and Replacing the Origin Vault Power Supply (Origin Vault) ..................11-29 11.10.1 Installing a New Power Supply In the Origin Vault Expansion Option ..............
  • Page 11 Serial Cables....................B-1 B.1.1 Printer/Character (ASCII) Terminal Cable......B-1 B.1.2 Modem Cable (Full-Handshake) ..........B-2 B.1.3 Origin200 to Indy and Indigo2 Cable (DB-9 to DIN-8) ..B-3 B.1.4 Origin200 to O2, Onyx2, and IBM-Compatible (DB-9 to DB-9)................B-3 B.1.5 Origin200 to Onyx (DB-9 to DB-9)..........B-4 B.1.6...
  • Page 13 xiii...
  • Page 14 The Origin200 Main System Board and CPU Daughter Card.... 1-8 Figure 1-5 PCI Backplane and Slot IDs ..............1-9 Figure 1-6 Layout of DIMM Sockets on the Origin200 Main System Board..1-11 Figure 1-7 Origin200 5.25-inch Peripheral Carrier and Drive Bay ..... 1-12 Figure 1-8 Origin200 3.5-inch Drive, Sled, and Bay..........
  • Page 15 Replacing the 5.25-Inch Peripheral Carrier ......... 3-16 Figure 3-16 Attaching an Ethernet Networking Cable to An Figure 3-17 Origin200 module ................... 3-17 Attaching the Serial Cable ..............3-18 Figure 3-18 Removing the Side Panel of the Second (Slave) Module ....3-20 Figure 3-19 Removing the Module System Controller (MSC) Access Plate..
  • Page 16 Turning Off the Front Power Switch............6-9 Figure 6-4 Turning Off the Master Power Switch ..........6-10 Figure 6-5 Attaching a Serial Cable To Port 1 of the Origin200 Server....6-14 Figure 6-6 Location of the AUX Port............... 6-21 Figure 6-7 Example /hw Filesystem .................
  • Page 17 Removing the Side Panel, Tower Origin200 Server......6-33 Figure 6-9 Opening the Chassis Access Door, Tower Origin200 ......6-34 Figure 6-10 Locking the Chassis With the Locking Tabs ........6-36 Figure 6-11 Adjusting the Feet ................... 6-37 Figure 6-12 Removing the Front Door, Tower Configuration....... 6-38 Figure 6-13 Removing the Front Door, Rackmount Configuration......
  • Page 18 How the 3.5-inch Drives are Numbered..........9-18 Figure 9-18 Removing a 3.5-inch Drive from Origin200 ........9-19 Figure 9-19 Location of the Serial Port Connectors on Origin200 ......9-22 Figure 9-20 Ethernet 10-Base-T/100-Base-TX Port LEDs........10-2 Figure 10-1 Location of the Power Supply Test Button and LED Figure 10-2 (Origin200 Shown) ..................
  • Page 21 Environment Specifications..............2-14 Characteristics and Types of Drives That Can Be Installed in Table 2-6 Origin Vault and Origin200..............2-14 Origin Vault and Origin200 3.5-Inch Disk Drive Specifications ..2-15 Table 2-7 Rackmount Enclosure Hardware ............. 4-7 Table 4-1 Information for Drive Configuration ............. 4-45...
  • Page 22 Terminal Serial Cable .................B-1 Cable Connector Pin Assignments for a Modem Cable ......B-2 Table B-2 Cable Connector Pin Assignments for an Origin200 To Indy and Table B-3 Indigo2 Serial Cable..................B-3 Cable Connector Pin Assignments for an Origin200 To O2, Onyx2, Table B-4 and IBM-Compatible Serial Cable ............B-3...
  • Page 23 Examples System Maintenance Menu ..............6-29 Example 6-1...
  • Page 25 About This Guide This guide describes how to set up and operate the Silicon Graphics Origin200 server and Origin Vault expansion option. Both chassis have two formats: a standalone tower and an enclosure that can be mounted in the Origin Rack or other Silicon Graphics rack.
  • Page 26 (FRUs) in both the Origin200 server and Origin Vault expansion chassis. • Appendix A, “Connector Pinout Assignments,” documents the pin assignments of the connectors on the back panels of both the Origin200 server and Origin Vault expansion chassis. • Appendix B, “Cable Descriptions,” describes the pin-to-pin wiring of the serial and AUX port cables that can be used with the Origin200 server.
  • Page 27 • IRIX Admin: Backup, Security, and Accounting Describes how to back up and restore files, how to protect your system’s and network’s security, and how to track system usage on a per-user basis. • IRIX Admin: Peripheral Devices Describes how to set up and maintain the software for peripheral devices such as terminals, modems, printers, and CD-ROM and tape drives.
  • Page 29 Chapter 1 Origin200: Overview and Theory of Operations The Origin200 server is a multiprocessor server that consists of one or two chassis or modules. Figure 1-1 shows a two-module system. Figure 1-1 Two-module Origin200 System, Front View Figure 1-2 shows a rear view of a two-module Origin200 system.
  • Page 30 Figure 1-2 Two-module Origin200 System, Rear View The Origin200 server can also be mounted in a 21-inch Silicon Graphics rack or a standard 19-inch rack. Figure 1-3 shows an example. Origin200: Overview and Theory of Operations...
  • Page 31 If you need to change an Origin200 server or Origin Vault from a tower configuration to a rack-mountable configuration, use the conversion kit P-S-RM-KIT.
  • Page 32 19-inch equipment racks. Multimodule Grounding and Site Preparation Like other members of the Origin family, the Origin200 server is extremely sensitive to differences in ground potential between modules. Multimodule systems are linked not only by a CrayLink Interconnect cable, but also by a grounding cable that ensures both modules are at the same potential.
  • Page 33 For additional information about power requirements, see Section 1.12, “Power Supply.” For environmental specifications, including operating and nonoperating conditions, see Section 1.14, “Physical and Environmental Specifications.” Logic Carrier The Origin200 logic carrier is a sheet-metal tray that holds: • the main system board •...
  • Page 34 1.4.1 Main System Board The main system board contains • two SCSI controllers for internal drives • Ethernet controller • two serial port interfaces (UARTs) • parallel port interface • three PCI expansion slots Origin200: Overview and Theory of Operations...
  • Page 35 (real-time) interrupt ports System controller connector Ethernet port connector Power connector Serial port connectors Parallel port connector CPU daughter card CrayLink Interconect connector Figure 1-5 The Origin200 Main System Board and CPU Daughter Card Origin200 and Origin Vault Installation Instructions...
  • Page 36 3.3V PCI cards with up to a total of 30 watts of 3.3V power. Figure 1-6 shows the location and slot numbers of the PCI backplane. PCI backplane Foot Feature cable connectors Rear of System PCI option slots PCI Backplane and Slot IDs Figure 1-6 Origin200: Overview and Theory of Operations...
  • Page 37 Memory Each Origin200 module can have between 32 MB and 2 GB of memory, depending upon the type of dual in-line memory module (DIMM) that you install. DIMMs are installed in sockets that are grouped into two banks of four sockets each. Figure 1-7 shows the layout of the DIMM sockets on the main system board.
  • Page 38 Maximum interleaving is achieved with a single bank. Internal Drive Options and SCSI Channels The Origin200 server provides bays for two sizes of internal drive options: 5.25-inch drives and 3.5-inch drives. 1-10 Origin200: Overview and Theory of Operations...
  • Page 39 Drives are mounted in a removable peripheral carrier, shown in Figure 1-8. 5.25-Inch Peripheral Carrier Origin200 5.25-inch Peripheral Carrier and Drive Bay Figure 1-8 1.7.2 3.5-Inch Drives and Drive Bay The 3.5-inch drive bay has room for six drives, mounted individually on sleds. The 3.5-inch drives are attached to SCSI channel 0.
  • Page 40 Figure 1-9 Origin200 3.5-inch Drive, Sled, and Bay 1.7.3 SCSI Channels and Channel Numbering There are two SCSI channels in each Origin200 module. Table 1-2 lists the channels in each module and their characteristics. Origin200 SCSI Channel Numbers and Characteristics...
  • Page 41 The serial port connectors are DB-9, male, and are designed to be IBM-compatible. Because of this, they do not use the same pinouts as prior Silicon Graphics DB-9 serial ports. For a description of the serial port pinouts, see Appendix A, “Connector Pinout Assignments.”...
  • Page 42 1.11 External Interrupt Ports The Origin200 server has two connectors for use with the external interrupt interface. This interface allows separate machines to send and receive interrupts over a dedicated wire for purposes of inter-machine synchronization. Using this device, a user process may generate outgoing interrupts to other machines, or receive interrupts from other machines in a variety of ways.
  • Page 43 1.13 Air Flow and Fans Air flow through Origin200 is from the front of the system to the rear, and is drawn by three DC fans located just behind the internal drive bays. The maximum flow rate is 100 cfm (0.047 m...
  • Page 44 Air is drawn up from PCI plenum duct, over PCI cards towards the fan plenum Figure 1-10 Air Flow Through Origin200 Air is drawn through the system in the following way: • Fan 1, directly behind the 5.25-inch peripheral carrier, draws air from the front of the system through the 5.25-inch peripheral carrier.
  • Page 45 (MSC) operates the fans at one of two speeds: low and high. Table 1-5 describes the relationship of the air temperature to fan speed. Table 1-5 Relationship of Air Temperature to Fan Speed in an Origin200 Server Air Temperature Action Less than 83.3°...
  • Page 46 Port and Module System Controller Commands.” For information about replacing fans, see Chapter 11, “Removing and Replacing Internal Parts.” 1.14 Physical and Environmental Specifications Table 1-7 lists the various physical and environmental specifications of the Origin200 server. Table 1-7 Origin200 Physical and Environmental Specifications Specification...
  • Page 47 Origin200 and Origin Vault Installation Instructions 1-19...
  • Page 48 1-20 Origin200: Overview and Theory of Operations...
  • Page 49 The Origin Vault expansion option is a drive enclosure that holds up to six 3.5-inch drives and either one full-height 5.25-inch drive or two half-height 5.25-inch drives. It provides expansion capacity for Silicon Graphics Origin2000, Origin200, and Onyx2 deskside and rackmount servers and workstations.
  • Page 50 The Origin Vault drive enclosure version can be mounted in the Origin2000 Rack (Origin Rack) or other 19-inch Silicon Graphics rack, the Origin SCSI expansion rack (P-S-RACK, 21 inches wide), or in an industry-standard 19-inch rack. The rackmountable version has a front bezel (different from that for the tower), as well as mounting hardware.
  • Page 51 Example Rackmounted Origin Vault Enclosure Figure 2-2 Early versions of the rackmountable Origin200 server and Origin Vault shipped Note: with mounting rails that attached to the inside of the equipment rack. The rails are no longer used and have been replaced by a mounting shelf that is easier to install in a wider variety of third-party 19-inch equipment racks.
  • Page 52 Internal Drive Options and SCSI Channels This section discusses • Section 2.2.1, “Drive Bay Locations” • Section 2.2.2, “Data Transfer Rates” • Section 2.2.3, “Single-Ended and Differential Versions (3.5-Inch Drive Controller)” • Section 2.2.4, “Drive Controller Connectors” 2.2.1 Drive Bay Locations Figure 2-3 shows drive bay locations in each format of the expansion option.
  • Page 53 SE SCSI port DF SCSI IN DF SCSI OUT for 5.25-inch port for 3.5-inch port for 3.5-inch drive(s) drives drives Main power Power cord switch connector Figure 2-4 Origin Vault Rackmountable Enclosure Rear View (Differential) Origin200 and Origin Vault Installation Instructions...
  • Page 54 In the differential version, the ports for the 3.5-inch drives are labeled for in and out connections, but they can be used interchangeably. If you use only one 3.5-inch drive connector in this version, you must terminate the unused one. In the tower with the single-ended 3.5-inch drive controller, the third SCSI connector (which is the second 3.5-inch drive controller connector, SCSI OUT) is not present;...
  • Page 55 Origin Vault Standalone Tower Rear View 2.2.5 Drives and Indicators This section explains • Section 2.2.5.1, “3.5-Inch Disk Drives” • Section 2.2.5.2, “5.25-Inch Drives” • Section 2.2.5.3, “Drive LEDs” • Section 2.2.5.4, “Drive Termination” Origin200 and Origin Vault Installation Instructions...
  • Page 56 P-S-9 The Origin Vault SCSI disk drives and their sleds are the same as those for the Origin2000 or Origin200 system. The Origin Vault 3.5-inch disk drives support administrative warm swap, as described in Chapter 9, “Installing and Configuring Peripherals.”...
  • Page 57 Use an uninterruptable power supply when possible. • If the standalone tower is connected to an Origin200 system, both systems must be plugged into the same grounded power circuit; otherwise, damage can result to components on the Origin200 system main system board.
  • Page 58 For more information, see Site Preparation for Origin Family and Onyx2 (007-3452-001). As with Origin200, air flow through either version of the Origin Vault expansion option is from the front of the system to the rear, and is drawn by three DC fans located just behind the drive bays.
  • Page 59 The differential version of the Origin Vault expansion option can be used in four configurations, summarized in Table 2-2. Table 2-2 Origin Vault Differential Configurations Hosts Origin Vault Description Expansion Options Single-host single-option Daisy-chained Dual-host single-option (failsafe) Dual-host dual-option (failsafe) Figure 2-10 diagrams the differential configurations. Origin200 and Origin Vault Installation Instructions 2-11...
  • Page 60 Origin 10 m Vault Origin Host Host expansion 10 m Vault option Host expansion option 10 m Single-host single-option Dual-host single-option Origin Origin Origin Origin 10 m Vault Vault 10 m Vault Vault Host Host Host expansion expansion expansion expansion option option option...
  • Page 61 0.98 (unity) Correction The Origin Vault power supply is identical to the one found in the Origin200 server. For additional information on the power supply, see “Power Supply” in Chapter 1. Table 2-5 lists operating environment conditions for the Origin Vault tower and rackmountable enclosure.
  • Page 62 Sensitive frequency: 8-33 Hz (varies with configuration) Table 2-6 summarizes types of drives that can be installed in the Origin Vault expansion cabinet (and Origin200 server). Origin Vault Table 2-6 Characteristics and Types of Drives That Can Be Installed in...
  • Page 63 Table 2-7 lists specifications for the 3.5-inch disk drives used at the time of this writing. Table 2-7 Origin Vault and Origin200 3.5-Inch Disk Drive Specifications Feature 4.5 MB 9.1 MB Connector SCA 80-pin SCA 80-pin Formatted capacity (MB) 4,550...
  • Page 65 Chapter 3 Setting Up an Origin200 System This chapter describes how to set up a one or two module Origin200 system. It includes the following sections: • Section 3.1, “Choosing a Location For the Server” • Section 3.2, “Putting the Pieces Together,” which includes –...
  • Page 66 3.1.1 Providing Correct Electrical Grounding (Earthing) Proper electrical grounding is critical. With a two-module system, both modules must be on the same, grounded power supply. Otherwise, the Origin200 system board will be damaged. Modules may be connected to different electrical circuits, but those circuits must originate at the same power supply (electrical service entrance or breaker box).
  • Page 67 40 pounds (18 kg) per module. Be aware that a fully-configured Origin200 module can weigh up to 75 pounds (34 kg) per module. Rackmounted Origin200 servers ship with a mounting shelf that can support the weight of a fully loaded system.
  • Page 68 The rackmounting shelf does not isolate the server from mechanical shock and Note: vibration. If you plan to use a rackmount Origin200 server in an environment that will subject the system to excess vibration, you should obtain a mounting system capable of dampening the vibration.
  • Page 69 Putting the Pieces Together Figure 3-3 shows the various items that are packed with a basic Origin200 server in a tower configuration. Software CDs AUX port cable Computer Systems (DIN-8 to DB25) Origin200 Owner's Guide Origin200 Owners Guide Console serial cable...
  • Page 70 Basic Items Included With the Origin200 Server, Rackmountable Configuration 3.2.1 Overview of the System Connectors and Ports When you assemble an Origin200 server you attach various cables (system console, power, Ethernet network, ground, and CrayLink Interconnect) to the rear of the system. Figure 3-5 provides an overview of the various connectors that are available.
  • Page 71 When working on an Origin200 server, follow these safety precautions: • Place the chassis on a surface capable of supporting a minimum of 40 lbs (about 18 kg) per module. A fully-configured Origin200 module can weigh up to 75 lbs (34 kg). •...
  • Page 72 Do not install additional or overpacked disk drives yet. These make the modules heavier and more difficult to move as you continue to set up the system. 4. If you are installing the Origin200 modules in an equipment rack, turn now to Chapter 5, “Installing an Origin200 System in a Rack.”...
  • Page 73 Slot 6 (SCSI ID 6) Slot 1 (SCSI ID 1) SCSI Drive ID Numbering for 3.5-Inch Drives Figure 3-6 Install any 3.5-inch drives as shown in Figure 3-7. Origin200 and Origin Vault Installation Instructions...
  • Page 74 Peripherals.” 3.2.5 Installing 5.25-Inch Drives Note: If you are installing a non-Silicon Graphics 5.25-inch drive, see Section 9.1, “Installing, Removing, and Configuring 5.25-Inch Peripherals.” 5.25-inch drives are installed in a removable carrier. Follow these step to remove the carrier: 1. Remove the door.
  • Page 75 Figure 3-8. The door will pop off its hinges. Removing the Front Door, Tower Configuration Figure 3-8 • If the system is in a rackmount configuration, lift the door assist tab and pull the door off, as shown in Figure 3-9. Origin200 and Origin Vault Installation Instructions 3-11...
  • Page 76 • Pull out the carrier handle. • Using a #2 Phillips screwdriver, release the captive screws that attach the carrier to the system. • Pull the carrier out of the system by the handle. 3-12 Setting Up an Origin200 System...
  • Page 77 2. Using a #2 Phillips screwdriver, remove the screws that hold the access plate to the rear of the carrier, then remove the access plate. See Figure 3-11. Front Rear Figure 3-11 Removing a Blanking Plate and the Rear Access Plate from the Peripheral Carrier Origin200 and Origin Vault Installation Instructions 3-13...
  • Page 78 4. Attach one of the power connectors at the rear of the carrier to the drive. Use whichever connector fits conveniently for the position of the drive’s power receptacle. See Figure 3-13. Carrier power receptacle Peripheral power connector Figure 3-13 Attaching a Power Connector to a 5.25-inch Drive 3-14 Setting Up an Origin200 System...
  • Page 79 6. Replace the access plate. See Figure 3-15. • The plate should cover all of the loose wires (power and SCSI) at the rear of the carrier. Rear Figure 3-15 Replacing the Rear Access Plate on the Peripheral Carrier Origin200 and Origin Vault Installation Instructions 3-15...
  • Page 80 See Figure 3-16. Figure 3-16 Replacing the 5.25-Inch Peripheral Carrier 3.2.6 Attaching an Ethernet Networking Cable Figure 3-17 shows how to attach an Ethernet 10-Base-T or 100-Base-TX cable to an Origin200 module. 3-16 Setting Up an Origin200 System...
  • Page 81 Figure 3-17 Attaching an Ethernet Networking Cable to An Origin200 module Category 5 wiring is required for proper 100-Base-TX operation. Note: 3.2.7 Attaching the System Console Connect the RS-232 serial cable (provided) to an ASCII terminal. The cable is approximately 10 feet (3 meters) long. Plug the D-shaped, 9-pin connector into serial port 1 on the back of the system, as shown in Figure 3-18.
  • Page 82 Console.” 3.2.8 Connecting Two Origin200 Modules When you connect two Origin200 modules together using a CrayLink Interconnect cable, one module becomes the master and the other becomes the slave. This relationship is set by a DIP switch located on the module system controllers (MSC) of the each machine, and has the following features: •...
  • Page 83 (current) can damage components on the Origin200 main system board. Follow these steps to connect two Origin200 modules: 1. If the slave system is in a tower configuration, remove the side panel as shown in Figure 3-19.
  • Page 84 Figure 3-20 Removing the Module System Controller (MSC) Access Plate 3. Locate the MSC DIP switch, as shown in Figure 3-21. 3-20 Setting Up an Origin200 System...
  • Page 85 Figure 3-22. • Connect the ground cable first. • Connect the CrayLink Interconnect cable and tighten the thumbscrews. Be sure to tighten the thumbscrews on the connectors for proper Craylink operation. Origin200 and Origin Vault Installation Instructions 3-21...
  • Page 86 You must connect the power cables to the same, grounded power supply or the system will be damaged. You are finished connecting the modules. You can now turn on the system. Turning On the System Follow these steps to turn on the system: 3-22 Setting Up an Origin200 System...
  • Page 87 When you turn on the master power switch, the status LED on the front panel flashes green momentarily. 2. At the front of the system, press the power button, as shown in Figure 3-24. Origin200 and Origin Vault Installation Instructions 3-23...
  • Page 88 1 (the system disk) and proceeding to slot 6. After the 3.5-inch drives, power is applied to the 5.25-inch drives. Logging In For the First Time When you log into the system for the first time, you perform the following tasks: 3-24 Setting Up an Origin200 System...
  • Page 89 Optional: Assign passwords to critical system accounts (such as root and httpd). • Optional: Allow or deny access to network services available on your Origin200 server (such as finger, ftp, telnet, and so forth.) You can perform these basic tasks from the system console (for example, an ASCII terminal) that you attached to serial port 1.
  • Page 90 3-26 Setting Up an Origin200 System...
  • Page 91 When opening the chassis to install or remove peripherals, always observe proper electrostatic discharge (ESD) procedures. Make sure you are properly grounded with a wrist or heel strap before handling drive assemblies. All Silicon Graphics peripheral upgrade options are shipped with wrist straps. Note: Origin200 and Origin Vault Installation Instructions...
  • Page 92 Choosing a Location for the Origin Vault Tower Follow these guidelines: • If the standalone tower is connected to an Origin200 system, both systems must be plugged into the same grounded power circuit; otherwise, damage can result to components on the Origin200 system main system board.
  • Page 93 1. Have ready a #2 Phillips screwdriver, a pair of needle-nosed pliers and a jumper that can connect two pins. 2. For an Origin Vault tower, remove the side panels, as shown in Figure 4-2. Origin200 and Origin Vault Installation Instructions...
  • Page 94 Figure 4-2 Removing Tower Side Panels 3. Lay the tower or rackmountable enclosure on a work surface with the top cover facing up, as shown in Figure 4-1. 4. Remove the two screws at the rear of the chassis that secure the top cover and remove the top cover.
  • Page 95 Do not attempt to open the power supply at any time. 5. Ground yourself with a wrist strap, as shown in Figure 4-4. The grounding strap is included in the Origin Vault shipment. Figure 4-4 Attaching the Grounding Strap Origin200 and Origin Vault Installation Instructions...
  • Page 96 6. Locate the ID-setting pins near the outer edge of the 3.5-inch backplane; see Figure 4-5. Notice the jumper (shunt) that is inserted over one pin. Jumper: SCSI address 1-6 Figure 4-5 SCSI Device ID Resetting Pins 7. Using the needle-nosed pliers, slide the jumper over the two pins. See Figure 4-6. Jumper: SCSI address 9-14 Figure 4-6 Setting 3.5-Inch Drive Device Numbering to 9 through 14...
  • Page 97 Section 4.5.3, “Securing the Enclosure in the Rack” • Section 4.5.4, “Removing the Enclosure Door (Optional)” • Section 4.5.5, “Cabling the Enclosure” The last three sections pertain to all types of racks. These procedures require a #2 Phillips screwdriver. Origin200 and Origin Vault Installation Instructions...
  • Page 98 4.5.1 Preparing the Enclosure for the Origin2000 Rack or P-S-RACK In an Origin2000 Rack or the P-S-RACK, the enclosure rests on rails, which are supplied in the rack. The Origin Vault enclosure for the Origin2000 Rack includes mounting ears that secure the enclosure in the rack and prevent it from sliding out.
  • Page 99 Figure 4-8 Attaching Rackmounting Hardware Origin200 and Origin Vault Installation Instructions...
  • Page 100 4.5.1.2 Preparing the Origin2000 Rack The Origin2000 Rack provides front and rear access. In the Origin2000 Rack, the rear is where the main power switch is located, as well as all of the connectors. To prepare the Origin2000 Rack, follow these steps: 1.
  • Page 101 Two pairs are included to accommodate the different widths of racks. Placing these end caps is explained in Section 4.5.3, “Securing the Enclosure in the Rack.” Origin200 and Origin Vault Installation Instructions 4-11...
  • Page 102 Preparing the rack and the enclosure consists of • Section 4.5.2.1, “Attaching Rack Brackets to the Enclosure” • Section 4.5.2.2, “Installing the Mounting Shelf” 4.5.2.1 Attaching Rack Brackets to the Enclosure The L-shaped mounting ears) are stamped “L” (part number 040-2007-001) and “R” (part number 040-2006-001) for left and right;...
  • Page 103 3. Place a washer between each screw head and the mounting shelf, as shown in Figure 4-13. Screw in the screws to install the mounting shelf. Figure 4-13 Installing the Rackmounting Shelf in a P-S-RACK or 19-Inch Industry-Standard Rack Origin200 and Origin Vault Installation Instructions 4-13...
  • Page 104 4.5.3 Securing the Enclosure in the Rack Follow these steps: 1. If the front door of the Origin Vault rackmountable enclosure is not locked, use the key to lock it so that the door cannot be pulled open accidentally when the enclosure is being installed.
  • Page 105 (P-S-RACK), use the larger pair of end caps; for a 19-inch third-party rack, use the smaller pair. Indentation Figure 4-15 Attaching End Caps (P-S-Rack) Attach the label to the indentation in the left end cap shown in Figure 4-15. Origin200 and Origin Vault Installation Instructions 4-15...
  • Page 106 5. If the Origin Vault option has a side-hinged door, attach it by plugging it into the holes in the U-shaped mounting ears, as shown in Figure 4-16. Faceplate with door closed Faceplate with door attached Figure 4-16 Installing Faceplate and Door: Origin2000 Rack 4-16 Setting Up an Origin Vault Expansion Option...
  • Page 107 Door Figure 4-17 Removing Faceplate and Door: Origin2000 Rack Use the single end cap provided to cover the end of the faceplate that is exposed when the door is removed. Origin200 and Origin Vault Installation Instructions 4-17...
  • Page 108 Figure 4-18 shows this operation in a third-party rack. Move the retention clip out of the way, continue pulling the door down, and it comes off. Retention clip Figure 4-18 Removing Faceplate and Door: Third-Party 19-Inch Rack 4.5.5 Cabling the Enclosure Before you cable the Origin Vault enclosure, note the following: •...
  • Page 109 Figure 4-19 Origin Vault Rackmountable Enclosure Rear View This section explains • Section 4.5.5.1, “Connecting to the Power Distribution Unit” • Section 4.5.5.2, “Cabling the 3.5-Inch Drive Controller” • Section 4.5.5.3, “Cabling the 5.25-Inch Drive Controller” Origin200 and Origin Vault Installation Instructions 4-19...
  • Page 110 4.5.5.1 Connecting to the Power Distribution Unit Connect the Origin Vault power cord to the Origin Rack power distribution unit, as shown in Figure 4-20. Power distribution OriginVault unit (PDU) Power cord Figure 4-20 Connecting the Rackmount Power Cable 4.5.5.2 Cabling the 3.5-Inch Drive Controller If the host is in the same rack, use the 1-meter SCSI cable to connect the single-ended 3.5-inch drives to these ports:...
  • Page 111 If the Origin Vault enclosure is interfacing with the Ultra SCSI option board, cable the Origin Vault SCSI to a SCSI connector of one of the Y cables supplied with the Ultra SCSI board option, not directly to the board, as shown in Figure 4-22. Origin200 and Origin Vault Installation Instructions 4-21...
  • Page 112 (the middle port) to a differential SCSI connector in the host. Figure 4-23 shows cabling to a differential PCI option board in an Origin200 tower. For information on daisy chaining a second Origin Vault to this one, connecting a...
  • Page 113 If the Origin Vault enclosure is interfacing with the Ultra SCSI option board, you cable the Origin Vault SCSI to a SCSI connector of one of the Y cables supplied with the Ultra SCSI board option, not directly to the board. Origin200 and Origin Vault Installation Instructions 4-23...
  • Page 114 If the customer is installing third-party peripherals, or wishes to change the configuration of a Silicon Graphics-supplied drive, he or she must follow these guidelines, which also appear in Chapter 2 of the Origin Vault Owner’s Guide: •...
  • Page 115 (EMI) shielding in the Origin Vault chassis. Origin200 and Origin Vault Installation Instructions 4-25...
  • Page 116 5. Insert each drive sled into a bay until it is almost flush with the edge of the drive bay, as shown in Figure 4-26 and Figure 4-27. Latch the drive: For a tower, pull the handle up to latch the drive; for an enclosure in a rack, pull the handle to the left.
  • Page 117 Set the drive (motor) start jumper to start on command from the host. Do not configure the drive to start as soon as power is applied, since this setting may draw too much current when the system is first turned on. Options from Silicon Graphics have this jumper set correctly.
  • Page 118 Carrier securing screws Figure 4-28 Unscrewing the Peripheral Carrier 3. Place the peripheral carrier on a work surface. Remove the EMI shielding plate from the rear of the peripheral carrier: • Unscrew the screw at the bottom of the EMI shielding plate on either side of the carrier, as shown in Figure 4-29.
  • Page 119 3. Attach a connector of the power cable to each peripheral; Figure 4-31 shows an example. Origin200 and Origin Vault Installation Instructions 4-29...
  • Page 120 Carrier power receptacle Peripheral power connector Figure 4-31 Attaching a Power Cable Connector to a Peripheral Inside the Carrier (Example) 4. Attach one of the SCSI connectors on the carrier’s internal SCSI cable to each peripheral; Figure 4-32 shows an example. If you are inserting only one peripheral, use either connector.
  • Page 121 If all four screw holes align with holes in the peripheral, insert screws in the holes closest to the edge of the carrier. 6. Reattach the EMI shielding plate. If you have removed both blanking plates but installed only one half-height peripheral, reinstall the extra blanking plate. Origin200 and Origin Vault Installation Instructions 4-31...
  • Page 122 7. Slide the carrier into the bay; note the orientation shown in Figure 4-34. Carrier securing screws Figure 4-34 Inserting the Peripheral Carrier Into the 5.25-Inch Bay Make sure the peripheral carrier is flush with the front of the Origin Vault. The connectors on the rear of the peripheral carrier mate with connectors on the 5.25-inch backplane.
  • Page 123 All Ultra SCSI XIO board channels are differential; channel 0 can be differential or single-ended. The PCI SCSI board option is available in single-ended or differential versions, as indicated by the icon near the board connector (see Figure 4-36). Origin200 and Origin Vault Installation Instructions 4-33...
  • Page 124 Single-ended Differential Figure 4-36 PCI SCSI Option Board Icons 3. Cable the SCSI connection(s): • Single-ended tower: Plug one of the 1-meter SCSI cables into the Origin Vault 3.5-inch controller port. Attach the other end of this cable to a single-ended SCSI connector in the host, such as the SCSI port on an Origin2000 IO6 board or the connector on the single-ended PCI option.
  • Page 125 Origin2000 Origin Vault 10-meter SCSI cable Figure 4-37 Origin Vault and Origin2000 Host (Differential) Figure 4-38 shows the SCSI cabling between a differential Origin Vault tower and an Origin200 host system. Origin200 and Origin Vault Installation Instructions 4-35...
  • Page 126 Figure 4-38 Origin Vault and Origin200 Host (Differential) Caution: When the standalone tower is connected to an Origin200 system, both systems must be plugged into the same grounded power circuit; otherwise, loss of signal integrity or possible damage can result to components on the Origin200 system main system board.
  • Page 127 4. Plug the other end of this cable into the 3.5-inch drive’s IN SCSI connector on the second Origin Vault. 5. If there is no terminator on the OUT SCSI connector on the second Origin Vault, attach one. Figure 4-40 shows an example. Origin200 and Origin Vault Installation Instructions 4-37...
  • Page 128 Origin2000 Origin Vault Origin Vault 10-meter SCSI cable 1-meter SCSI cable Terminator Figure 4-40 Origin2000 System and Daisy-Chained Origin Vault Options 4.10 Adding a Second Host to One Origin Vault Expansion Option Figure 4-41 diagrams cabling two hosts to one Origin Vault expansion option. Origin 10 m Vault...
  • Page 129 4. Attach the other end of this cable to a differential SCSI connector in the second host, such as the Y cable to channel 1, 2, or 3 on the Ultra SCSI XIO board. Figure 4-42 shows an example. Origin200 and Origin Vault Installation Instructions 4-39...
  • Page 130 Origin2000 Origin Vault Origin2000 10-meter SCSI cable 10-meter SCSI cable Figure 4-42 Dual-Hosted Configuration Sharing One Origin Vault Option For dual-hosting, such as for an OPS or IRIS FailSafe configuration, follow Note: configuration instructions in the latest version of the Oracle Parallel Server Installation and Maintenance Instructions or IRIS FailSafe Installation and Maintenance Instructions, respectively.
  • Page 131 OUT port. 4. Set up and cable the second host-option pair, attaching the 10-meter cable to the Origin Vault option’s 3.5-inch IN controller port. Remove the terminator from the second option’s OUT port. Origin200 and Origin Vault Installation Instructions 4-41...
  • Page 132 5. Connect the two Origin Vault options with the 1-meter cable, cabling the two OUT ports. Figure 4-44 shows an example. Origin2000 Origin Vault Origin Vault Origin2000 10-meter SCSI cable 1-meter SCSI cable 10-meter SCSI cable Figure 4-44 Dual-Hosted Configuration Sharing Two Origin Vault Options For dual-hosting, such as for an OPS or IRIS FailSafe configuration, follow Note: configuration instructions in the latest version of the Oracle Parallel Server...
  • Page 133 (or the master power switch is turned on). Prior revisions did not have this feature and required an operator to press the front power switch whenever the module lost power, or the rear power switch was turned off. Origin200 and Origin Vault Installation Instructions 4-43...
  • Page 134 4.13 Verifying Drive Installation Use the following checklist to determine if a drive is installed correctly in the Origin Vault tower or rackmounted enclosure: • When you power on the system, watch the drive LEDs. The LEDs should blink one after the other as they are accessed: first the 3.5-inch drives (sequentially), and then the 5.25-inch drives.
  • Page 135 4.14 Configuring Drives Silicon Graphics-provided peripherals are all recognized by the IRIX operating system and are ready to be configured for use with the system. For general reference on disks and filesystems, consult the latest edition of IRIX Admin: Disks and Filesystems. Table 4-2 indicates where to get more information about configuring drives, depending upon how...
  • Page 137 Chapter 3, “Setting Up an Origin200 System.” If you have an Origin200 server in a tower configuration, and you wish to convert it to a rackmount configuration, a conversion kit is available from Silicon Graphics (P-S-RM-KIT).
  • Page 138 The ears do not bear any of the server’s weight. Follow these steps to install the mounting ears on the chassis: 1. Place the Origin200 on a flat, sturdy work surface capable of supporting at least 40 pounds (18 kg) and up to 75 pounds (34 kg).
  • Page 139 Using a #2 Phillips screwdriver and the 6-32 x 1/4-inch screws provided with the Origin200, fasten each ear to the side of the chassis, behind the front flange, as shown in Figure 5-3. Use two screws for each mounting ear.
  • Page 140 Installing the Rackmounting Shelf The mounting shelf provided with the Origin200 server takes up 4 U (7 inches, or 17.8 cm) of space in the rack and supports the weight of the server. Installing an Origin200 System in a Rack...
  • Page 141 Earlier versions of the rackmount Origin200 server shipped with side rails. The Note: side rails have been replaced by the mounting shelf, which can be installed in a wider variety of third-party equipment racks. Follow these steps to install the mounting shelf in your equipment rack: 1.
  • Page 142 2. With a person on each side of the chassis, lift the server and move it to the equipment rack, as shown in Figure 5-5. Lifting the Origin200 Server Into a Rack Figure 5-5 3. Place the server in the rack on top of the mounting shelf, then slide it back into the rack.
  • Page 143 first time. Removing a Server From an Equipment Rack If you have a two-module Origin200 system, be extremely careful with the CrayLink cable. Do not bend or yank on it while removing the server from the equipment rack.
  • Page 144 6. With two people, slide the server out of the rack, as shown in Figure 5-7. Figure 5-7 Removing An Origin200 From a Rack 7. If you are servicing the Origin200, place it on a flat, sturdy work surface capable of supporting at least 40 pounds (18 kg). •...
  • Page 145 Figure 5-8 Placing the Origin200 on a Work Surface You are finished removing the server from a rack. Origin200 and Origin Vault Installation Instructions...
  • Page 146 5-10 Installing an Origin200 System in a Rack...
  • Page 147 Chapter 6 Origin200 Server Operations This chapter describes various features the Origin200 server and how to use them. It contains the following sections: • Section 6.1, “Front Panel Functions: Status LED, Power, Reset, NMI” • Section 6.2, “Turning the System On and Off”...
  • Page 148 Status LED Front Power switch Figure 6-1 The Origin200 Front Panel 6.1.1 Status LED The actual status LED is part of the system controller assembly, which is located behind the front panel. A piece of light-conductive plastic (light pipe) channels the light from the LED to the front panel.
  • Page 149 Generating an NMI is can be useful when attempting to solve application and system problems that cause the system to halt. An NMI on the Origin200 server has roughly the same effect as on other machines in the Origin family.
  • Page 150 6.2.1 About the Master Power Switch and Front Power Switch The Origin200 server has two power switches: the master power switch and the front power switch. The master power switch is located at the rear of the system. This switch controls whether or not current flows into the power supply.
  • Page 151 When you turn on the master power switch, the status LED at the front of the system flashes green momentarily. 2. At the front of the system, press the power button, as shown in Figure 6-3. Origin200 and Origin Vault Installation Instructions...
  • Page 152 1 (the system disk) and proceeding to slot 6. After the 3.5-inch peripherals, power is applied to the 5.25-inch peripherals. 3. You see several screens of diagnostic messages as the system performs various self-tests. Origin200 Server Operations...
  • Page 153 Option? 4. At the System Maintenance Menu, type and press < >. Enter • The Origin200 server starts booting IRIX. • You should see various messages, followed by the login prompt: • IRIS login: • When you see the “login” prompt, the system is finished booting and it is ready to If desired, you can configure the server to boot IRIX automatically without...
  • Page 154 (the master chassis in a two-module system) and press it once. See Figure 6-4 Figure 6-4 Turning Off the Front Power Switch • The status LED on the front of the system blinks, then goes out when the system is powered off. Origin200 Server Operations...
  • Page 155 AUX port. Accessing the Server Over the Web The Origin200 server is bundled with World-Wide Web server software that allows you to access the system with a browser from any other computer on your network. In order to do...
  • Page 156 3.5-inch peripheral bay. See Figure 9-12, in Section 9.2.1, “About the 3.5-Inch Peripheral Bay.” The former slave system may not display any output on the system console for up to 5 minutes. This is normal Allow the system to run through its normal process of determining 6-10 Origin200 Server Operations...
  • Page 157 (such as Term, HyperTerm, TERMINAL.EXE, Bitcom, Procomm, ZTerm, SITcomm, or Macterm) The basic steps to using a computer as a system console for your Origin200 server are: • Connect a serial port of the computer to serial port 1 of the Origin200 server.
  • Page 158 6.5.1.2 Setting Up and Starting the Terminal Emulator To communicate with the Origin200 server, you need a terminal emulator for your IBM compatible or Macintosh computer. Many operating systems, such as Microsoft Windows, ship with a terminal emulator package (also known as modem or communications software.) Some examples of terminal emulator software include.
  • Page 159 • Note which terminal type (such as VT100 or ANSI) you choose to emulate. You will need this information when you log in to the Origin200 server. • Other settings, such as upload and download protocol, initialization strings, and file transfer settings do not matter for this procedure.
  • Page 160 < >, make sure the cables are correctly attached. The DB9 connector on Enter the long serial cable (shipped with the Origin200 server) must be in port 1 of the server. • Make sure you have configured the terminal emulator to use the correct serial port on your computer.
  • Page 161 Origin200 server and another serial port on the workstation • use the cu command on the workstation to connect to the Origin200 server and log in 6.5.2.1 Obtaining the Correct Serial Cable If you are connecting the Origin200 to a Silicon Graphics workstation, you need one of three RS-232 serial cables: •...
  • Page 162 Direct ttyd2 - 9600 direct • This change allows you to use port 2 on the workstation to connect to the Origin200 server. If you are using a different serial port, replace in the line ttyd2 above with the name of the actual port you are using, for example...
  • Page 163 Using the AUX Port and Module System Controller Commands The AUX port is an 8-pin mini-DIN connector at the rear of the Origin200 server that connects to the module system controller (MSC). Figure 6-7 shows the location of the AUX port.
  • Page 164 Appendix B, “Cable Descriptions.” You can also use the descriptions provided in that appendix to construct your own cables. Note that the cables are the same as the ones used for Silicon Graphics Indy, Indigo, and Indigo workstations, and the CHALLENGE S server.
  • Page 165 The following sections describe various common tasks you can perform with the MSC. In all cases, you enter commands and see the indicated responses on a terminal or other input device connected to the AUX port of the Origin200 server. 6.6.2.1...
  • Page 166 6.6.2.2 Setting the MSC Password Supervisor Mode on the MSC is protected by a four-character password. By default, every Origin200 server ships with an MSC password, which is the word “none.” To change the password, enter: <Ctrl>t pas s xxxx In the above example, xxxx is the new four-character password.
  • Page 167 Origin200 server is installed is within proper specifications. To determine the proper ambient air temperature, see Section 1.14, “Physical and Environmental Specifications”...
  • Page 168 AutoLoad to “yes.” See Section 6.7, “About the PROM Monitor” and the prom(1M) and nvram(1M) reference pages for more information about the system PROM. 6.6.2.9 Resetting the System To reset the system, use this command: <Ctrl>t rst 6-22 Origin200 Server Operations...
  • Page 169 MSC will automatically switch the fan speed to high if one of the fans fails. fan n Set the fans to run at normal speed. fan h Set the fans to run at high speed. Send a hardware nonmaskable interrupt (NMI) to the system. Origin200 and Origin Vault Installation Instructions 6-23...
  • Page 170 Enter Supervisor Mode; xxxx is the four-character password for your system. All Origin200 servers ship with the word “none” as the default password. pas s xxxx Set the password to xxxx. Note that the password must be exactly 4 characters long.
  • Page 171 Command Monitor by typing at the Command Monitor prompt ( ). PROM configuration variables can also be changed from >> an IRIX shell prompt using the nvram command, which is described on the nvram(1M) reference page. Origin200 and Origin Vault Installation Instructions 6-25...
  • Page 172 Determining What Devices are Installed On the Server Because the Origin200 server, like the rest of the Origin product line, is a highly-configurable, multi-module system, there are some differences in the way that devices are identified and configured from prior Silicon Graphics workstations and servers.
  • Page 173 To determine I/O devices of the module, follow the directory structure. Figure 6-8 shows a simplified example of a /hw/module filesystem with two nodes (modules); in the second module, there are two CPUs and one XIO board. Origin200 and Origin Vault Installation Instructions 6-27...
  • Page 174 Because of the weight of an Origin200 system, two people are required to lift and move the chassis. To remove the system cover and chassis access panel of an Origin200 server, follow these steps: 1. Power off the system. See Section 6.2.3, “Turning Off the System.”...
  • Page 175 • Optional: you can remove the door by lifting it up slightly and away from the chassis. In some cases, it may be easier to service the Origin200 if you remove the chassis access door. Origin200 and Origin Vault Installation Instructions...
  • Page 176 Figure 6-10 Opening the Chassis Access Door, Tower Origin200 6.10 Locking the System The Origin200 provides two mechanisms to physically lock the system: • a key lock on the front door • removable tabs to lock the chassis cover 6-30...
  • Page 177 To lock the chassis, you use the two metal tabs that are provided with the system. Figure 6-11 provides an overview of the process. Figure 6-11 Locking the Chassis With the Locking Tabs Follow these steps to lock the chassis (refer to Figure 6-11). Origin200 and Origin Vault Installation Instructions 6-31...
  • Page 178 4. Insert a lock, cable, or other device through the holes in the tabs. 6.11 Adjusting the Feet The feet on an Origin200 server in a tower configuration can be swiveled in or out. See Figure 6-12. Figure 6-12 Adjusting the Feet To adjust the feet: 1.
  • Page 179 6.12 Removing the Front Door The front door of an Origin200 server has several features: • In a tower configuration, the door is designed to release from its hinges if it is struck while open, or otherwise forced too far open.
  • Page 180 Figure 6-14 Removing the Front Door, Rackmount Configuration Early versions of the Origin200 and Origin Vault did not have this door assist tab. 6.13 Removing the Feet, Side Panel, and Exterior Plastic Parts of a Tower System If desired, you can remove the feet, system cover, side panel, and most of the exterior plastic parts from an Origin200 server in a tower configuration.
  • Page 181 Insert a flat-blade screwdriver between one side of the lower bezel and the sheet metal, as shown in Figure 6-16. • Twist the screwdriver to disengage the lower bezel from the sheet metal. Origin200 and Origin Vault Installation Instructions 6-35...
  • Page 182 40 pounds (18 kg) and up to 75 pounds (34 kg). Be careful not to scratch or damage the front bezel. • Using a #2 Phillips screwdriver, remove the four screws that hold the pedestal assembly to the chassis and remove the pedestal assembly. 6-36 Origin200 Server Operations...
  • Page 183 Figure 6-17 Removing the Pedestal Assembly (Feet) Origin200 and Origin Vault Installation Instructions 6-37...
  • Page 184 6-38 Origin200 Server Operations...
  • Page 185 Origin200 and Origin Vault Installation Instructions 6-39...
  • Page 186 6-40 Origin200 Server Operations...
  • Page 187 Origin200 and Origin Vault Installation Instructions 6-41...
  • Page 188 6-42 Origin200 Server Operations...
  • Page 189 Origin200 and Origin Vault Installation Instructions 6-43...
  • Page 191 32 MB DIMMs while bank 1 has a pair of 64 MB DIMMs and bank 2 has another pair of 32 MB DIMMs. • Each module must have memory installed (32 MB minimum per module); slave modules must have the minimum of 32 MB installed. Origin200 and Origin Vault Installation Instructions...
  • Page 192 4. Attach a grounding strap to your wrist. • All Silicon Graphics options, including memory, are shipped with wrist straps to help prevent damage to components from static electricity. • Attach the strap to your wrist as shown on the wrist-strap package, and in Figure 7-1.
  • Page 193 Attaching A Grounding Wrist Strap Figure 7-1 5. Locate the DIMM banks. See Figure 7-2. Origin200 and Origin Vault Installation Instructions...
  • Page 194 DIMM banks Figure 7-2 Locating DIMMs In the Origin200 6. Install DIMMs in pairs, starting with bank 0 (the pair farthest away from the center of the banks) and working inward. Figure 7-3 shows the grouping of DIMM pairs: Installing and Removing Memory...
  • Page 195 8 6 4 2 Bank 3 Bank 1 Rear of System How DIMM Pairs Are Grouped in Origin200 Figure 7-3 • Figure 7-3 shows one pair of DIMMs installed in bank 0 (mandatory for both master and slave modules). If you are installing one additional pair of DIMMs, install them in bank 1.
  • Page 196 Figure 7-4 Installing a DIMM • As you lower the DIMM into its socket, press down first on one side then the other to seat the DIMM (upper drawing). • Press straight down across the entire top to make sure the DIMM is firmly seated. Avoid placing sideways pressure on the DIMM.
  • Page 197 DIMMs you installed is not seated correctly. Shut down the system and reseat the DIMMs. Removing Memory Follow these steps to remove memory from an Origin200 server. 1. Shut down the system completely. See Section 6.2.3, “Turning Off the System.”...
  • Page 198 Figure 7-5 Attaching A Grounding Wrist Strap 5. Locate the DIMMs. See Figure 7-6. Installing and Removing Memory...
  • Page 199 DIMM banks Figure 7-6 Locating DIMMs In the Origin200 6. Always remove DIMMs in pairs. starting with the pair closest to the center of the banks (bank 4). See Figure 7-7. Origin200 and Origin Vault Installation Instructions...
  • Page 200 Bank 3 Bank 1 Rear of System Figure 7-7 How DIMM Pairs Are Grouped In Origin200 • Start by removing bank 4, then bank 3, then bank 2. • If you have a two-node system, you must have at least one bank of memory installed in both master and slave nodes in order for the system to operate.
  • Page 201 The lever raises the DIMM out of that side of its socket. • Grasp the DIMM along the edges and pull it up out of its socket with an end-to-end rocking motion. (Avoid excess side-to-side motion, as this may damage the socket.) Origin200 and Origin Vault Installation Instructions 7-11...
  • Page 202 7. After you have finished removing DIMMs, remove your wrist strap and reassemble the system. • Replace the chassis access door and side panel (the reverse of removing them). • Reattach the cables to the back of the system. 7-12 Installing and Removing Memory...
  • Page 203 Chapter 8 Installing and Removing PCI Option Boards This chapter describes how to install and remove PCI option boards in a Origin200 server. Handling Precautions Warning: Option boards are sensitive to electrostatic discharge (ESD). Observe the following precautions when installing and removing memory: •...
  • Page 204 4. Attach a grounding strap to your wrist. • All Silicon Graphics options, including PCI boards, are shipped with wrist straps to help prevent damage to components from static electricity. • Attach the strap to your wrist as shown on the wrist-strap package, and in Figure 8-1.
  • Page 205 Using a #2 Phillips screwdriver, remove the single screw that secures the blanking pate to the chassis. See Figure 8-3. • Remove the blanking plate by lifting it straight up, as shown in Figure 8-3. Origin200 and Origin Vault Installation Instructions...
  • Page 206 Figure 8-3 Removing a PCI Slot Blanking Plate Installing and Removing PCI Option Boards...
  • Page 207 To install such a board in an Origin200 server, you must install a cable from a connector on the board to the feature connector on the PCI backplane. If you are not sure if the PCI board you are installing uses a feature-connector, refer to Figure 8-4.
  • Page 208 PCI backplane feature connectors are found in logic carriers starting with Note: p/n 013-1937-002 (1 processor) and 013-1938-002 (2 processors). • Connect the other end of the cable to the Origin200 feature connector on the PCI board, as shown in Installing and Removing PCI Option Boards...
  • Page 209 Be careful not to kink or damage the flexible EMI gasket that surrounds the inside of the rear chassis wall. • Attach the screw that secures the PCI option board to the chassis, as shown in Figure 8-7. Origin200 and Origin Vault Installation Instructions...
  • Page 210 Replace the chassis access door and side panel (the reverse of removing them). • Reattach the cables to the back of the system. Do not discard the blanking plate that you removed from the Origin200 chassis. If Note: you ever decide to remove the PCI option board, you must replace this blanking plate to ensure proper airflow through the Origin200 chassis.
  • Page 211 Removing a PCI Option Board The following steps describe how to remove a PCI option board from a Origin200 server. 1. Shut down the system completely. See “Turning Off the System” in Chapter 6. • Be sure to turn off the master power switch.
  • Page 212 5. Locate the PCI option board you wish to remove. 6. Remove the board. • Using a #2 Phillips screwdriver, remove the screw that secures the PCI option board to the Origin200 chassis, as shown in Figure 8-9. 8-10 Installing and Removing PCI Option Boards...
  • Page 213 Place the PCI option board in an anti-static bag, preferably the bag in which the board was originally packaged. 7. Replace the blanking plate. • Align the blanking plate and slide it in place, as shown in Figure 8-10. Origin200 and Origin Vault Installation Instructions 8-11...
  • Page 214 Replace the chassis access door and side panel (the reverse of removing them). • Reattach the cables to the back of the system. Note: You must replace the blanking plate to cover the gap in the rear of the Origin200 chassis in order to ensure proper airflow through the chassis. 8-12...
  • Page 215 5.25-inch drive bay. 9.1.1 About the 5.25-Inch Peripheral Bay The 5.25-inch drive bay is located at the top of the Origin200 in a tower configuration, or on the left-hand side in a rack-mount configuration. Figure 9-1 shows the location of the 5.25-inch drive bay.
  • Page 216 5.25-Inch Drive Bay Figure 9-1 Location of the 5.25-Inch Drive Bay The 5.25-inch drive bay holds a peripheral carrier (mounting frame) to the drives are attached. The carrier is open at the front to accept drives, and has blind-mating connectors at the rear for power and SCSI data.
  • Page 217 9.1.2 Configuring a 5.25-Inch Peripheral Peripherals obtained from Silicon Graphics are pre-configured. You can install them in the 5.25-inch drive bay with no additional configuration. However, if you are installing third-party peripherals, or wish to change the configuration of a Silicon Graphics-supplied drive, follow these guidelines: •...
  • Page 218 Figure 9-3 Removing the 5.25-Inch Peripheral Carrier 2. Prepare the peripheral carrier, as shown in Figure 9-4. • Remove one or two of the blanking plates from the front of the carrier, depending upon whether you are installing a half-height or a full-height peripheral. •...
  • Page 219 SCSI cables from damage when you slide the carrier into the system. Front Rear Rear Figure 9-5 Installing a 5.25-Inch Drive in the Peripheral Carrier 6. Slide the carrier into the system and secure it with the two captive screws. See Figure 9-6. Origin200 and Origin Vault Installation Instructions...
  • Page 220 Pull out the peripheral carrier handle. The handle will flex downward, allowing access to two captive screws. • Using a #2 Phillips screwdriver, undo the two captive screws that secure the peripheral carrier to the Origin200 chassis. Installing and Configuring Peripherals...
  • Page 221 2. Remove the rear access plate from the peripheral carrier, as shown in Figure 9-8. • Using a #2 Phillips screwdriver, remove the screws that hold the access plate to the rear of the carrier, then remove the access plate. Origin200 and Origin Vault Installation Instructions...
  • Page 222 Rear Figure 9-8 Removing the Rear Access Plate from the Peripheral Carrier 3. Disconnect the power and SCSI cables from the drive. 4. Remove the screws that hold the drive to the peripheral carrier and remove the drive from the carrier, as shown in Figure 9-9. Front Figure 9-9 Removing A Drive From the Peripheral Carrier...
  • Page 223 Front Rear Figure 9-10 Replacing the Front Blanking Plate and Rear Access Plate 6. Slide the carrier into the system and secure it with the two captive screws. See Figure 9-11. Origin200 and Origin Vault Installation Instructions...
  • Page 224 Figure 9-11 Replacing the 5.25-Inch Peripheral Carrier Installing, Removing, and Configuring 3.5-Inch Peripherals The Origin200 chassis has room for six 3.5-inch peripherals. Each peripheral is mounted on a sled to make it convenient to install and remove the peripherals, and set their SCSI ID numbers.
  • Page 225 EMI shielding. Figure 9-13 Example 3.5-Inch Drive Slot Blanking Plate 9.2.2 Configuring 3.5-Inch Peripherals 3.5-inch peripherals obtained from Silicon Graphics are pre-configured and installed on drive sleds. You can install them in the 5.25-inch drive bay with no additional configuration.
  • Page 226 9.2.3 Installing a 3.5-Inch Peripheral Follow these steps to install a 3.5-inch peripheral: 1. Open the front door of the chassis as shown in Figure 9-14. Figure 9-14 Opening the Front Door of Origin200 2. Locate an available slot for the peripheral. •...
  • Page 227 Slot 6 (SCSI ID 6) Slot 1 (SCSI ID 1) Figure 9-15 How the 3.5-inch Drives are Numbered in Origin200 If desired, you change the range of 3.5-inch SCSI drive IDs to 9 through 14 using a jumper on the SCSI backplane. See “Jumpering the 3.5-Inch SCSI Device ID Range” in Chapter 4.
  • Page 228 Figure 9-16 Installing a 3.5-inch Peripheral The customer should save the blanking plates you remove. If the peripheral is ever Note: removed and not replaced, the blanking plate should be reinstalled plate to ensure proper cooling air flow and electromagnetic interference (EMI) shielding in the chassis.
  • Page 229 1. Open the front door of the chassis, as shown in Figure 9-17. Figure 9-17 Opening the Front Door 2. Locate the drive you want to remove. • The drives are numbered as shown in Figure 9-18. Origin200 and Origin Vault Installation Instructions 9-15...
  • Page 230 Slot 6 (SCSI ID 6) Slot 1 (SCSI ID 1) Figure 9-18 How the 3.5-inch Drives are Numbered 3. Remove the drive, as shown in Figure 9-19. • Pull the locking lever down. • Grasp the lever and pull the drive straight out of the chassis. 9-16 Installing and Configuring Peripherals...
  • Page 231 Figure 9-19 Removing a 3.5-inch Drive from Origin200 4. If you are not replacing the drive with another peripheral, cover the open slot with a plastic blanking plate, as shown in Figure 9-19. Always cover an open peripheral slot with a plastic blanking plate to ensure Note: proper cooling air flow and electromagnetic interference (EMI) shielding in the...
  • Page 232 2) and no drives installed in channel 1. Using Drives In the Origin200 Once installed, Silicon Graphics-provided peripherals are all recognized by the operating system (IRIX) and are ready to be configured for use with the system. Table 9-1 indicates where to turn for more information about configuring drives, depending upon how you...
  • Page 233 I/O is supported via operating system patches. Attaching Serial Devices Each Origin200 module provides connectors for two serial ports at the rear of the chassis. Figure 9-20 shows the locations of the connectors for these ports. Origin200 and Origin Vault Installation Instructions...
  • Page 234 Rear of System Figure 9-20 Location of the Serial Port Connectors on Origin200 In a one-module system, the ports are numbered 1 and 2. In a two-module system, the ports on the first module are numbered 1 and 2, and the ports on the second module are numbered 3 and 4.
  • Page 235 9.5.2 Attaching Serial (ASCII) Terminals You can connect an optional ASCII terminal to your Origin200 by using the serial cable shipped with your server. It has a DB-9 connector on one end and a 25-pin serial connector on the other. See Appendix B, “Cable Descriptions” for information on this cable.
  • Page 236 Use the following steps to properly connect a terminal: 1. Attach the keyboard (if applicable) and power connectors to the terminal. Caution: Before plugging the terminal into either a 110-VAC or 220-VAC outlet, be sure that the electrical rating on the UL-CSA label is in either the 100–120 VAC or 200–240 VAC range, whichever applies.
  • Page 237 This indicates that a getty process is running on both the system console (port 1) and on port 3. If you do not see a getty process running on the desired serial port, verify the serial port settings in /etc/inittab and rerun telinit. Origin200 and Origin Vault Installation Instructions 9-23...
  • Page 238 9.5.3 Connecting a Modem To attach a modem to your server, connect it to ports 2, 3, or 4using a serial modem cable. The serial cable must be appropriate for data communications equipment (DCE): the data transmit and data receive pins are opposite those in a DTE cable. Also, the cable must provide full flow control.
  • Page 239 • stty • termio The following files are commonly used to properly configure serial port operation for the Origin200 server: • /etc/inittab • /etc/gettydefs • /etc/ttytype • /usr/lib/terminfo • /etc/uucp/Devices • /etc/uucp/Systems Origin200 and Origin Vault Installation Instructions 9-25...
  • Page 240 9-26 Installing and Configuring Peripherals...
  • Page 241 Origin200 and Origin Vault Installation Instructions 9-27...
  • Page 243 Chapter 10 Troubleshooting This chapter the various LEDs that are on the Origin200 server. It also describes how to check the power supply of the Origin200 server and Origin Vault expansion option. 10.1 Status LED Messages The status LED on Origin200 server front panel can display three colors: green, amber, red.
  • Page 244 Packet detect (yellow) Figure 10-1 Ethernet 10-Base-T/100-Base-TX Port LEDs The transmit LED (green) flashes whenever the Origin200 is transmitting data through the Ethernet port. The packet detect LED (yellow) flashes whenever the server detects network traffic, even if the data detected is not destined for the server.
  • Page 245 10.3 Checking the Power Supply There is a test button and LED located on the base of the power supply of the Origin200 and Origin Vault, as shown in Figure 10-2. Power supply Front of system test button Area of...
  • Page 247 Chapter 11 Removing and Replacing Internal Parts This chapter describes how to remove and install internal parts of the Origin200 server and Origin Vault expansion option. It contains the following sections: • Section 11.1, “Tools Required to Remove and Replace Components”...
  • Page 248 The procedures in this step apply to all subsequent service instructions in this chapter, except for replacing the module system controller. Follow these steps to prepare the Origin200 server or Origin Vault expansion option for servicing: 1. Shut down the system.
  • Page 249 Note that the power cable plugs differ from each other. Figure 11-2 shows their locations. • If you are able, detach the SCSI cable from its connector; otherwise, wait until the backplane is partway out of the chassis. Origin200 and Origin Vault Installation Instructions 11-3...
  • Page 250 12V power connector SCSI backplane Spring clip SCSI connector 5V power connector Figure 11-2 Cable Connections and Spring Clips On the SCSI Backplane 3. Snap down the six spring clips on the SCSI backplane, as pointed out in Figure 11-2. 4.
  • Page 251 Fan 3 Fan 2 Fan 1 Figure 11-3 Disconnecting the Fan and Fan Power Cable (Other Components Removed For Clarity) 3. Lift the fan out of the system, as shown in Figure 11-4. Origin200 and Origin Vault Installation Instructions 11-5...
  • Page 252 Replacing the Module System Controller Note: For this procedure, you do not have to follow the instructions in “Preparing the Origin200/Origin Vault for Servicing.” The module system controller can be removed with the system in place and fully assembled. 11-6...
  • Page 253 Figure 11-5 Removing the Front Bezel Crossbar 4. Using a #2 Phillips screwdriver, remove the two screws that fasten the system controller assembly to the chassis, as shown in “Replacing the Module System Controller.” Origin200 and Origin Vault Installation Instructions 11-7...
  • Page 254 System Controller Figure 11-6 Removing the System Controller Assembly From the Chassis 5. Pull out the system controller assembly and lay it on a flat worksurface. Warning: To prevent ESD damage to the module system controller, be careful not to touch the board’s edge connectors (gold fingers). 6.
  • Page 255 The NIC stores the system serial number, so it is vital to keep the NIC with the system chassis. 11.6.1 Installing a New Module System Controller Follow these steps to attach a new module system controller board to the sheet metal carrier and install it in the system: Origin200 and Origin Vault Installation Instructions 11-9...
  • Page 256 3. Remove the disks (or blanking plates if no disks are installed) from slots 5 and 6 of the Origin200 server. Removing the disks (or blanking plates) allows you to see how the edge connector on the module system controller board aligns with its socket inside the chassis.
  • Page 257 Figure 11-9 Unfastening the PCI Plenum Divider Sheetmetal 4. Lift the PCI plenum divider sheetmetal out of the system, as shown in Figure 11-10. Origin200 and Origin Vault Installation Instructions 11-11...
  • Page 258 Figure 11-10 Removing the PCI Plenum Divider 5. Disconnect the cables that are attached to the logic carrier, as shown in Figure 11-11. • Detach the two SCSI cables. • Disconnect the power connector. • Remove the system controller cable. •...
  • Page 259 Figure 11-11 Disconnecting Cables from the Logic Carrier 6. Unfasten the captive screws and sheet metal screws that secure the logic carrier. See Figure 11-12. Origin200 and Origin Vault Installation Instructions 11-13...
  • Page 260 Figure 11-12 Unfastening the Logic Carrier 7. Lift the logic carrier out of the system, as shown in Figure 11-13. • Grasp the logic carrier handle with one hand and the connector panel with the other. • As you lift the logic carrier, tilt the side with the CPU daughter card up slightly higher than the side with the PCI backplane.
  • Page 261 Figure 11-13 Removing the Logic Carrier 11.7.1 Installing a New Logic Carrier Follow these steps to replace the logic carrier. Origin200 and Origin Vault Installation Instructions 11-15...
  • Page 262 1. Lower the new logic carrier into the system, as shown in Figure 11-14. Figure 11-14 Lowering A Logic Carrier Into the System 2. Secure the logic carrier by tightening the captive fasteners and installing the sheet metal screws, as shown in Figure 11-15. 11-16 Removing and Replacing Internal Parts...
  • Page 263 Figure 11-15 Fastening the Logic Carrier 3. Attach the power, SCSI, and system controller cables to the logic carrier, as shown in Figure 11-16. Origin200 and Origin Vault Installation Instructions 11-17...
  • Page 264 Figure 11-16 Attaching the Logic Carrier Cables 4. Install the PCI plenum divider sheet metal as shown in Figure 11-17. • Be extremely careful not to pinch the SCSI cables when installing the PCI plenum divider. • Make sure that the SCSI cables are not underneath the plenum divider captive screw.
  • Page 265 Figure 11-17 Installing the PCI Plenum Divider 5. Fasten the PCI plenum divider by tightening the captive screw and installing the sheet metal screw, as shown in Figure 11-18. Origin200 and Origin Vault Installation Instructions 11-19...
  • Page 266 To replace the board that converts the 3.5-inch drive controller from single-ended to differential, you remove the L-shaped converter board carrier (also known as the logic carrier—very different from the Origin200 server’s logic carrier) from the chassis and remove the converter board from it. Follow these steps: 1.
  • Page 267 3.5 Inch drive cable connector Power connector Figure 11-19 Detaching the Converter Board Cables 4. With a #2 Phillips screwdriver, unscrew the four screws that secure the converter board carrier, as shown in Figure 11-20. Origin200 and Origin Vault Installation Instructions 11-21...
  • Page 268 Captive screw Captive screw Power cable Convertor board carrier Captive screw Captive screw Screws Figure 11-20 Unscrewing the Converter Board Carrier: Two Views 5. Detach the converter board’s power cable and place the converter board carrier on the work surface. 6.
  • Page 269 11.9 Checking and Replacing the Origin200 Power Supply The power supplies used in the Origin200 server and Origin Vault expansion option are identical. However, because of slight differences between each chassis, the procedures for Origin200 and Origin Vault Installation Instructions...
  • Page 270 Origin200 server and Origin Vault expansion option. This section describes how to remove the Origin200 server power supply. To remove the Origin Vault power supply, see Section 11.10, “Checking and Replacing the Origin Vault Power Supply (Origin Vault).”...
  • Page 271 Figure 11-23 Removing the Origin200 Server Power Supply 11.9.1 Installing a New Power Supply In the Origin200 Server Follow these steps to install a new power supply in an Origin200 server: 1. Lower the power supply into the chassis with the power switch and receptacle towards the rear of the system.
  • Page 272 8. If the system is in a tower configuration, replace both side panels. 11.10 Checking and Replacing the Origin Vault Power Supply (Origin Vault) The power supplies used in the Origin200 server and Origin Vault expansion option are identical. However, because of slight differences between each chassis, the procedures for removing and replacing the power supply varies between the Origin200 server and Origin Vault expansion option.
  • Page 273 5. Slide the power supply forward (towards the fans) until it unlatches 6. Lift the power supply up and out of the chassis. See Figure 11-25. Figure 11-25 Removing the Origin Vault Power Supply Origin200 and Origin Vault Installation Instructions 11-27...
  • Page 274 3. Replace the six screws that secure the power supply to the rear of the chassis. See Figure 11-25. • Unlike Origin200, there is no screw securing the bottom of the power supply, only the six screws at the rear of the chassis. 4. Replace the L-shaped differential/single-ended SCSI converter board. See Section 11.8, “Replacing the Differential/Single-Ended Converter Board (Origin...
  • Page 275 Origin200 and Origin Vault Installation Instructions 11-29...
  • Page 276 11-30 Removing and Replacing Internal Parts...
  • Page 277 Origin200 and Origin Vault Installation Instructions 11-31...
  • Page 279 Appendix A Connector Pinout Assignments This appendix describes the pinouts of the following external connectors on the Origin200 server: • Section A.1, “Serial Ports” • Section A.2, “Parallel Port” • Section A.3, “Ethernet Port” • Section A.4, “AUX Port” (module system controller) •...
  • Page 280 Origin200 Parallel Port Pinout Assignments The Origin200 parallel port uses a 36-pin Centronics connector (IEEE 1284-C). An adapter cable is available from Silicon Graphics that attaches to the 36-pin port and provides a 50-pin Centronics connector (p/n 018-0611-001). Connector Pinout Assignments...
  • Page 281 Table A-2 shows the connector pinout assignments for the parallel port. Table A-2 Origin200 Parallel Port Pin Assignments Assignment DATA1 DATA2 DATA3 DATA4 DATA5 DATA6 DATA7 DATA8 BUSY ONLINE PR/SC NOPAPER (Not Connected) NOINK (Not Connected) 19–30 Signal Ground (GND) RESET 32–36 (Not Connected) Origin200 and Origin Vault Installation Instructions...
  • Page 282 Ethernet Port Transmit (green) Packet detect (yellow) Figure A-3 Origin200 Ethernet 10-BASE T/100-BASE TX Port Pinout Assignments Table A-3 shows the connector pinout assignments for the Ethernet 10-Base-T/100-Base-TX port. Table A-3 Origin200 Ethernet 10-Base-T/100-BASE TX Port Pin Assignments Assignment Transmit + Transmit –...
  • Page 283 External Interrupt Ports The external interrupt interface uses two 1/8” (3.5 mm) stereo jacks: one to generate interrupts and one to receive interrupts. The jacks are located on the back of the Origin200 server and are wired as indicated in Table A-5.
  • Page 284 Single-Ended SCSI (Origin Vault) Table A-6 lists the pinouts for the single-ended connection on an Origin Vault expansion option. In this table, the hyphen preceding a signal name indicates that the signal is low. Origin Vault 68-Pin Single-Ended High-Density SCSI Pinouts Table A-6 Signal Name Pin Number...
  • Page 285 TERMPWR TERMPWR Reserved Reserved -ATN +ATN Ground Ground -BSY +BSY +ACK -ACK +RST -RST -MSG +MSG +SEL -SEL -C/D +C/D +REQ -REQ +I/O -I/O Ground Ground +DB(8) -DB(8) -DB(9) +DB(9) +DB(10) -DB(10) +DB(11) -DB(11) Origin200 and Origin Vault Installation Instructions...
  • Page 286 Connector Pinout Assignments...
  • Page 287 Origin200. B.1.1 Printer/Character (ASCII) Terminal Cable Use this cable to attach a printer or a character (ASCII) terminal to Origin200. The server ships with a cable of this type, and you can purchase an additional or replacement cable from Silicon Graphics or your local service provider.
  • Page 288 (except printers and terminals) that do not need RTS/CTS flow control and you can use it with a null modem adapter to attach printers and character terminals. You can purchase this full-handshake serial cable from Silicon Graphics or from your local service provider.
  • Page 289 Clear To Send (CTS) (Not Connected) B.1.4 Origin200 to O2, Onyx2, and IBM-Compatible (DB-9 to DB-9) This connects an Origin200 to Silicon Graphics O2 and Onyx2 workstations, and IBM-compatibles with a DB-9 serial port. Table B-4 shows the cable connector pin assignments.
  • Page 290 B.1.5 Origin200 to Onyx (DB-9 to DB-9) This connects an Onyx to the Origin200. Notice that the Onyx DB-9 pin assignments are different from the Origin200 DB-9 pin assignments. Table B-5 shows the cable connector pin assignments. Table B-5 Cable Connector Pin Assignments for an Origin200 to Onyx Serial Cable...
  • Page 291 B.2.1 AUX Port Terminal Cable Use this cable to connect the Origin200 AUX port to a terminal. Note that this cable is identical to the one used to attach a terminal to a Silicon Graphics Indy, Indigo, or Indigo2 workstation and CHALLENGE S server.
  • Page 292 Table B-8 shows the cable connector pin assignments. Table B-8 Connector Pin Assignments for an AUX Port Modem Cable Pin Number Pin Number DB-25 Signal DIN-8 Connector Connector (Male) (Male) Data Terminal Ready (DTR) Clear To Send (CTS) Transmit Data (TXD) Ground (GND) Receive Data (RXD) Request To Send (RTS)
  • Page 293 Origin200 and Origin Vault Installation Instructions...
  • Page 295 LEDs 2-9 single-ended 2-5 speed 2-4 termination 2-6, 2-9 Symbols /dev directory 6-31 accessing the Origin200 server over the Web 6-11 /etc/gettydefs file 9-24 accessing the server over the Web 3-26 /etc/inittab file 6-18, 9-24 adding /etc/ioconfig utility 6-30 3.5-inch peripherals 9-14 /etc/ioconfig.conf file 6-30...
  • Page 296 B-1 connecting Origin200 to Indy, Indigo2 serial 9-23, B-1 with a serial cable B-3 wiring descriptions of B-1 connecting Origin200 to O2, Onyx2, and IBM- carrier compatibles peripheral 9-8 with a serial cable B-3 peripheral in Origin200 3-11...
  • Page 297 2-5, 4-19 SCSI channels available for 9-2 cabling SCSI channels available in Origin200 1-5 rackmounted 4-22 SCSI IDs assigned in Origin200 3-8, 3-9 tower 4-34 SCSI IDs assigned to 9-3, 9-12, 9-15 configuration 2-11–2-12 using in Origin200 9-20 termination 2-9...
  • Page 298 LED 6-1, 6-2, 10-1 attaching cable to Origin200 3-17 cable required for 100-Base-TX 1-15 front power switch 3-25, 6-2, 6-4 cable used for 100-Base-TX with Origin200 3-17 in a slave module 6-6 connector pin assignments A-4 ftp service 3-26...
  • Page 299 1-4 in an Origin200 server 1-6 installing replacing 11-12 3.5-inch peripherals 9-14 5.25-inch peripherals 9-4 an Origin200 in an equipment rack 5-6 fans 11-7 logic carrier 11-17 Macintosh memory (DIMMs) 7-2, 7-6 using as a system console 6-13...
  • Page 300 6-23 tower 2-2 modules clearances 2-10, 4-2 numbering in the hardware graph 6-32 location 4-2 power circuit with Origin200 2-9, 4-2, 4-36 mounting power cord connection 4-36 ears 4-7, 4-8 powering on 4-43 See also rack brackets...
  • Page 301 6-12 Digital Audio Option (RADical) board 8-5 serial ports 1-5 feature-connector option 8-5 size of (dimensions) 1-20 installing an option board in Origin200 8-8 turning off 6-7 installing boards 8-1 turning on 6-5 location of option slots 8-3...
  • Page 302 1-16 3.5-inch peripherals 9-17 power switch 4-25, 4-43 5.25-inch peripherals 9-8 a second module 6-12 power switches an Origin200 from an equipment rack 5-9 description of 6-4 fans 11-6 front 6-4 memory 7-7, 7-11 master 3-24, 6-4 Index-8...
  • Page 303 9-23 replacing serial cables B-1 logic carrier 11-12 serial ports module system controller (MSC) 11-11 available on an Origin200 server 1-5 Origin Vault power supply 11-29 connector pin assignments A-2 Origin200 power supply 11-24 numbering 1-14 SCSI backplane 11-5...
  • Page 304 6-12, 6-17 cabling 4-21, 4-23 System Maintenance Menu 6-7, 6-8, 6-16 SCSI channels 4-19 and the PROM monitor 6-29 using drives in the Origin200 server 9-20 entering the Command Monitor 6-30 UUCP software options 6-29 determining if installed on Origin200 6-18...
  • Page 305 XFS filesystem 9-21 Origin200 and Origin Vault Installation Instructions Index-11...

This manual is also suitable for:

Origin vault