Preface Respected users: Thank you for choosing a new MAC electronic equipment. In order to use this instrument correctly, please read the full text of this manual carefully before using this instrument, especially about the "safety precautions" part. If you have read the full text of this manual, it is recommended that you keep it properly together with the instrument or where you can read it for future use.
MATRIX TECHNOLOGY INC. All rights reserved. ● Products are protected by patents in China or other countries,including patents obtained or under application. ●MATRIX TECHNOLOGY INC. reserves the right to change the product specifications and prices. ● is a registered trademark of MATRIX TECHNOLOGY INC.
Page 4
Verification and Correction Statement The company specifically declares that the instruments and equipment listed in this manual fully conform to the specifications and characteristics stated in the company's technical specifications. This instrument has passed the factory calibration of the company before leaving the factory, and the calibration procedures and steps are in line with the specifications and standards of the electronic inspection center.
Safety precautions The following general safety precautions must be followed during all stages of this instrument operation. If these are not followed Preventive actions or specific warnings described in other parts of this manual will violate the design and manufacture of the instrument Safety standards for use.
CONTENTS Chapter Ⅰ Inspection and Installation ..............................1 1.1 Packing list .....................................1 1.2 Install the power supply ................................2 1.3 Adjust the power supply handle ............................3 1.4 Install the power supply cord ..............................3 Chapter II Quick Start ....................................5 2.1 Introduction ....................................5 2.2 Introduction to the front panel ..............................6 2.3 Introduction to Keyboard Keys ..............................
Chapter Ⅰ Inspection and Installation Before installation or operation, read this manual. 1.1 Packing list Open the package, please check the items in the box before operating the instrument. If there is any discrepancy, missing or external wear, Please contact the seller quickly. Accessories name quantity Note instructions...
Please follow the following power supply size introduction Select the right space for the installation. WPS series of programmable power supply size: 215mmW * 90mmH * 355mmD / 215mmW * 90mmH * 452mm (W: width; H: Height; D: depth)
1.3 Adjust the power supply handle Adjust the position of the power supply, grasp the handle with both hands, pull it out to the left and right sides, and then turn the handle to the desired position place. The location of the power supply has the following three options: Place on the table Hand position Note:...
Page 10
Types of power cords: The power cord model provided as standard with the power supply is shown in the following figure. Please select the power cord model that is suitable for the voltage in your region from the power cord specification table below.
WPS series power supply is also equipped with a standard RS232/USB/RS485 communication interface and an optional LAN interface, which combines the characteristics of desktop and system models.
WPS series power supply selection table: voltage current output power type 600W WPS600-8030L WPS 400-8020L 400W 200W WPS200-8010L 100W WPS 100-8005L 2.2 Introduction to the front panel Front panel layout: 1. VFD display screen 2. Knob 3. Power switch, Menu key, and Shift key 4.
2.3 Introduction to Keyboard Keys The key instructions are shown in the table below: Name and function Digital input key Decimal point / version number, machine temperature query (version number, machine temperature query, and shift composite key combination) Cancel / return to the key Voltage setting key, set the power supply output voltage value / overvoltage protection function key, with To set the overvoltage protection point of the power supply.
2.4 VFD indicator light function description When the power is turned on, if any of the marked states appear on the power, the relevant mark will be displayed in the lower left corner of the screen. The functional description of VFD indicator light is shown in the table below: symbol Functional Description Front disc locking mode...
4. Remote measurement terminal 5. AC power input socket and fuse 6. RS485 communication interface 7. Housing grounding terminal (When using the instrument, the housing must be grounded to prevent accidents.) Note: The 110V/220V power switch is located at the bottom of the instrument. Please check the switch position before inserting the power to avoid burning the instrument.
Page 16
1. Check if the power cord is connected correctly and confirm that the power supply is in a powered state. Good power cord connection =>2 Power connection error=>Please reconnect the power cord and check if the abnormality is cleared. 2. Is the power on. Press the power switch key to be in the power on state. Yes =>3 No =>Please press the voltage switch to turn on the power and check if the abnormality is cleared.
2.7 Output check The output check ensures that the power supply reaches its rated output and performs the front panel operation correctly. Output voltage check: Verify the basic voltage function of the power supply without load. 1. Turn on the power supply. 2.
Chapter III Functions and Features This chapter details the functions and characteristics of the power supply. It will be divided into the following sections: Switch between local / remote operations Voltage setting operation Current-setting operation Output the on / off operation ...
Storage contents include: voltage setting and current setting, OVP / OCP setting. Call operation: The parameters are retrieved from the designated memory area using the front panel ‘Recall’ key + numeric keys 1-9 key. 3.7 List (List test function) Press the ‘List’ key in the standby state, enter the "List" menu setting function, the screen shows below, available key to move the cursor and press the button ‘ESC’...
When the total list length is set press the Enter key to enter list cycle test settings options, shown as follows:(global cycle Up to 9999 times can be edited, and 0 is an infinite loop.) Cycles=3:3 cycles (9999 times) 3. When the total number of cycles is set Press the Enter key to enters list the setting of the test parameters Options, displayed below (press the Enter key confirm the parameters and move the cursor, press click to switch the list):...
Page 22
Output Status Settings Output parameter settings beeper setup Command Settings Communication settings Reset Exit 3.8.1.1 Out State Move the cursor to the position where "Out State" is located and press the "Enter" key. The power supply will enter the function options for output state settings, as shown below (you can move the cursor with the key and confirm with the key):...
3.8.1.2 Out Param Move the cursor to the "Out Param" position and press "Enter", and the power will enter the output parameter setting key move the cursor, ’ENTER’ button confirmation): Can option, shown below (available 3.8.1.3 Keep (buzzer setup): Move the cursor to the "Keep" position and press "Enter", the key, the power supply will enter the work of the buzzer setting key move the cursor, ’ENTER’...
Page 24
* SCPI protocol has the setting of the end character, namely CR, LF, CR + LF, LF + CR. The setting of the end must be communicated with the host computer the consistent power supply can communicate normally. 3.8.1.6 Reset (reset system set to factory default) Move the cursor to the "Reset"...
3.8.2.1 Min Voltage: Move the cursor to the Min Voltage position and press Enter and the power supply to the minimum voltage range Set function options as follows (number key 0-9 available import ’ENTER’, Key confirmation): 3.8.2.2 Max Voltage: Move the cursor to the "Max Voltage" position and press Enter and the power will enter the maximum voltage range set function options as follows (number key 0-9 available import ’ENTER’, Key confirmation): 3.8.2.3 Min Current:...
3.11 DVM measuring function WPS series power supply built-in four and a half voltmeter. Through the DVM port on the back of the instrument can be measured at 0.001V DC voltage to 80.000V and measured through the panel composite key (Shift) +’List’...
3.12 Power supply temperature / version number query Through the front panel composite button (Shift) + button, you can query the power supply temperature / version number and other information, the VFD display is as follows, press ‘Esc’ Key exit: Model Version Machine internal temperature...
Chapter IV Technical 4.1 Main technical specifications Technical specification sheet: 4.2 Supplementary Features Status memory capacity: 99 sets of operation states Recommended calibration frequency: 1 year / 1 time Heat dissipation mode: forced air cooling Operating ambient temperature: 0 to 40℃ Storage ambient temperature: -20 to 70℃...
Chapter V Communication between power supply and PC WPS series, power supply standard with three communication interfaces: RS232, USB, RS485, users can choose any one to achieve and calculate machine communication. Communication Settings Before doing communication operations, you should first match the power supply with the following parameters of the PC.
Page 30
Vout Constant Voltage Constant Current Iout Imax The working mode of the power supply can be indicated by the marked area of the VFD. If CV is displayed, the power supply operates in constant voltage mode. If CC appears, the power supply operates in constant current mode.
What the warranty covered: If the machine break down due to its defectiveness, MATRIX will provide free maintenance during warranty period. If the machine break down due to wrong operation or carelessness, then Matrix provide paid service within warranty period.
Need help?
Do you have a question about the WPS Series and is the answer not in the manual?
Questions and answers