Series Nine GAS WATER HEATER USER’S GUIDE FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES C3 Technology® Gas Water Heaters meet the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
IMPORTANT DEFINITIONS • Maytag Customer Service Center: The Maytag Customer Service Center has the equivalent to a licensed tradesman in the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters.
TABLE OF CONTENTS SAFE INSTALLATION, USE AND SERVICE ....................SAFETY PRECAUTIONS ..........................TABLE OF CONTENTS ..........................CUSTOMER RESPONSIBILITIES ........................ PRODUCT SPECIFICATIONS ........................ACCESSORIES AND TOOLS NEEDED ...................... Accessories ................................6 Tools ..................................6 INSTRUCTIONS FOR INSTALLATION ......................Removing the Old Water Heater ..........................7 TYPICAL INSTALLATION ..........................
CUSTOMER RESPONSIBILITIES In the United States: The National Fuel Gas Code ANSI Thank You for purchasing a Maytag water heater. Properly Z223.1/NFPA 54. This publication is available from the installed and maintained, it should give you years of trouble CSA International, 8501 East Pleasant Valley Rd, Cleveland free service.
ACCESSORIES AND TOOLS NEEDED Accessories To simplify the installation Maytag has available the installation parts shown below. You may or may not need all of these accessories depending on your type of installation. Call Maytag Customer Service at 1-800-788-8899 for an authorized installer.
INSTRUCTIONS FOR INSTALLATION Removing the Old Water Heater 4. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining.
TYPICAL INSTALLATION GET TO KNOW YOUR WATER HEATER - GAS MODELS A Vent Pipe J Drip Leg (Sediment Trap) S Flue Baffle B Draft Hood K Inner Door T Thermostat C Anode L Outer door U Drain Valve D Hot Water Outlet M Union V Pilot and Main Burner E Outlet...
Mixing valves are available at plumbing supply or hardware stores. See Figure 8. Valves for reducing point of use temperature by mixing cold and hot water are also available. Consult Maytag Customer Service (1-800-788-8899). Follow mixing valve manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Temperature Regulation”...
LOCATING THE NEW WATER HEATER Facts to Consider About the Location • Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply. Carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance.
Insulation blankets available to the general public for external be allowed on some models, refer to the label attached adjacent use on gas water heaters are not necessary with Maytag to the gas control valve on the water heater, see Figure 9.
top and one commencing within 12 inches (30 cm) from the Combustion Air and Ventilation for bottom of the enclosure. The openings shall communicate Appliances Located in Unconfined Spaces directly, or by ducts, with the outdoors or spaces (crawl or attic) that freely communicate with the outdoors.
Refer to the Thermal Expansion section under Troubleshooting requiring a certain temperature water at the hot water tap, then Guide or contact local plumbing authority or call Maytag you must take special precautions. In addition to using the Customer Service at 1-800-788-8899 for an authorized lowest possible temperature setting that satisfies your hot water installer on how to control this situation.
• Look at the top of the water heater. The cold water inlet is marked “COLD”. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the 3/4” NPT threaded nipple. Using standard pipe fittings, connect the cold water pipe to the cold water inlet of the water heater.
If replaced, the valve must meet the requirements of local The Discharge Pipe: codes, but not less than a combination temperature and pressure relief valve certified as indicated in the above • Shall not be smaller in size than the outlet pipe size of the paragraph.
ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically and mechanically actuated vent dampers). Before installation Obstructed or deteriorated vent systems may present serious of any vent damper, consult your Maytag Customer Service health risk or asphyxiation. Center at 1-800-788-8899 or the local gas supplier for further information.
4 percent for each 1,000 feet (305 m) above sea level which requires replacement of the burner orifice in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact Maytag Customer Service Center at 1-800-788-8899 or your local gas supplier or call for further information.
Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated in the piping.
OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES A.
Valves for reducing the point-of-use temperature by mixing cold Temperature Regulation and hot water are available. See Figure 8. Also available are inexpensive devices that attach to faucets to limit hot water temperatures. Contact a licensed plumber or the local plumbing authority.
In some water areas, sediment can be removed by can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY draining off approximately one gallon of water each month. DAMAGE. Contact the Maytag dealer from whom the appliance was purchased or call Maytag Customer Service at Vent System Inspection 1-800-788-8899 for an authorized servicer to replace a flooded water heater.
You may have a check valve installed in the water line or a water meter with a check valve. Consult Maytag Customer Service at 1-800-788-8899 for further information. Do not plug the temperature-pressure relief valve.
• Turn “OFF” gas supply to water heater. If a condition persists or you are uncertain about the operation of the water heater, let the Maytag Customer Service Center • Follow “Draining” instructions. check it out. • Turning counter clockwise (...
It is non-resettable. If the high temperature Shut-off condensation, loose connections, or the relief valve. activates, the gas control valve must be replaced. Call Maytag DO NOT replace the water heater until a full inspection of all Customer Service at 1-800-788-8899 for an authorized possible water sources is made and necessary corrective servicer.
TROUBLESHOOTING GUIDE These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at 1-800-788-8899 for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product. Problem Cause Solution Improperly sealed, hot or cold supply connection, Tighten threaded connections.
Now that you have purchased this gas water heater, should a need When ordering repair parts, always give the following information: ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an authorized servicer. Be sure to •...
Page 30
Now that you have purchased this gas water heater, should a need When ordering repair parts, always give the following information: ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an authorized servicer. Be sure to •...
This warranty is limited to the original owner of the water heater. TO RECEIVE WARRANTY SERVICE To locate an authorized service company in your area contact the Maytag dealer from whom your appliance was purchased; or call Maytag Customer Service at the number listed below. Should you not receive satisfactory...