Maytag HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T User Manual

Maytag HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T User Manual

Series nine, for potable water heating only not suitable for space heating not for use in manufactured (mobile) homes

Advertisement

Series Nine
GAS WATER HEATER
USER'S GUIDE
FOR POTABLE WATER HEATING ONLY
NOT SUITABLE FOR SPACE HEATING
NOT FOR USE IN
MANUFACTURED (MOBILE) HOMES
C3 Technology® Gas Water Heaters meet
the new ANSI Z21.10.1 standard that deals
with the accidental or unintended ignition
of flammable vapors, such as those
emitted by gasoline.
PRINTED IN THE U.S.A . 0905
AN ODORANT IS ADDED TO THE GAS USED
www.maytagwaterheaters.com
1
Model Numbers
HRN4930T
HRP4930T
HRN4940S
HRP4940S
HRN4940T

For Your Safety

BY THIS WATER HEATER.
HRP4940T
HRN4950S
HRP4950S
HRN4950T
HRP4950T
PART NO. 184382-001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T and is the answer not in the manual?

Questions and answers

Summary of Contents for Maytag HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T

  • Page 1: For Your Safety

    Series Nine GAS WATER HEATER USER’S GUIDE FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES C3 Technology® Gas Water Heaters meet the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
  • Page 2: Safe Installation, Use And Service

    IMPORTANT DEFINITIONS • Maytag Customer Service Center: The Maytag Customer Service Center has the equivalent to a licensed tradesman in the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS SAFE INSTALLATION, USE AND SERVICE ....................SAFETY PRECAUTIONS ..........................TABLE OF CONTENTS ..........................CUSTOMER RESPONSIBILITIES ........................ PRODUCT SPECIFICATIONS ........................ACCESSORIES AND TOOLS NEEDED ...................... Accessories ................................6 Tools ..................................6 INSTRUCTIONS FOR INSTALLATION ......................Removing the Old Water Heater ..........................7 TYPICAL INSTALLATION ..........................
  • Page 5: Customer Responsibilities

    CUSTOMER RESPONSIBILITIES In the United States: The National Fuel Gas Code ANSI Thank You for purchasing a Maytag water heater. Properly Z223.1/NFPA 54. This publication is available from the installed and maintained, it should give you years of trouble CSA International, 8501 East Pleasant Valley Rd, Cleveland free service.
  • Page 6: Accessories And Tools Needed

    ACCESSORIES AND TOOLS NEEDED Accessories To simplify the installation Maytag has available the installation parts shown below. You may or may not need all of these accessories depending on your type of installation. Call Maytag Customer Service at 1-800-788-8899 for an authorized installer.
  • Page 7: Instructions For Installation

    INSTRUCTIONS FOR INSTALLATION Removing the Old Water Heater 4. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining.
  • Page 8: Typical Installation

    TYPICAL INSTALLATION GET TO KNOW YOUR WATER HEATER - GAS MODELS A Vent Pipe J Drip Leg (Sediment Trap) S Flue Baffle B Draft Hood K Inner Door T Thermostat C Anode L Outer door U Drain Valve D Hot Water Outlet M Union V Pilot and Main Burner E Outlet...
  • Page 9: Mixing Valve Usage

    Mixing valves are available at plumbing supply or hardware stores. See Figure 8. Valves for reducing point of use temperature by mixing cold and hot water are also available. Consult Maytag Customer Service (1-800-788-8899). Follow mixing valve manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Temperature Regulation”...
  • Page 10: Locating The New Heater

    LOCATING THE NEW WATER HEATER Facts to Consider About the Location • Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply. Carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance.
  • Page 11: Insulation Blankets

    Insulation blankets available to the general public for external be allowed on some models, refer to the label attached adjacent use on gas water heaters are not necessary with Maytag to the gas control valve on the water heater, see Figure 9.
  • Page 12: In Unconfined Spaces

    top and one commencing within 12 inches (30 cm) from the Combustion Air and Ventilation for bottom of the enclosure. The openings shall communicate Appliances Located in Unconfined Spaces directly, or by ducts, with the outdoors or spaces (crawl or attic) that freely communicate with the outdoors.
  • Page 13: Water Piping

    Refer to the Thermal Expansion section under Troubleshooting requiring a certain temperature water at the hot water tap, then Guide or contact local plumbing authority or call Maytag you must take special precautions. In addition to using the Customer Service at 1-800-788-8899 for an authorized lowest possible temperature setting that satisfies your hot water installer on how to control this situation.
  • Page 14: T & P Valve And Pipe Insulation

    • Look at the top of the water heater. The cold water inlet is marked “COLD”. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the 3/4” NPT threaded nipple. Using standard pipe fittings, connect the cold water pipe to the cold water inlet of the water heater.
  • Page 15: Filling The Water Heater

    If replaced, the valve must meet the requirements of local The Discharge Pipe: codes, but not less than a combination temperature and pressure relief valve certified as indicated in the above • Shall not be smaller in size than the outlet pipe size of the paragraph.
  • Page 16: Venting

    ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically and mechanically actuated vent dampers). Before installation Obstructed or deteriorated vent systems may present serious of any vent damper, consult your Maytag Customer Service health risk or asphyxiation. Center at 1-800-788-8899 or the local gas supplier for further information.
  • Page 17: Gas Piping

    4 percent for each 1,000 feet (305 m) above sea level which requires replacement of the burner orifice in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact Maytag Customer Service Center at 1-800-788-8899 or your local gas supplier or call for further information.
  • Page 18: Sediment Trap

    Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated in the piping.
  • Page 19: Operating Instructions

    OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES A.
  • Page 20: Temperature Regulation

    Valves for reducing the point-of-use temperature by mixing cold Temperature Regulation and hot water are available. See Figure 8. Also available are inexpensive devices that attach to faucets to limit hot water temperatures. Contact a licensed plumber or the local plumbing authority.
  • Page 21: Service And Maintenance

    In some water areas, sediment can be removed by can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY draining off approximately one gallon of water each month. DAMAGE. Contact the Maytag dealer from whom the appliance was purchased or call Maytag Customer Service at Vent System Inspection 1-800-788-8899 for an authorized servicer to replace a flooded water heater.
  • Page 22: Housekeeping

    You may have a check valve installed in the water line or a water meter with a check valve. Consult Maytag Customer Service at 1-800-788-8899 for further information. Do not plug the temperature-pressure relief valve.
  • Page 23: Drain Valve Washer Replacement

    • Turn “OFF” gas supply to water heater. If a condition persists or you are uncertain about the operation of the water heater, let the Maytag Customer Service Center • Follow “Draining” instructions. check it out. • Turning counter clockwise (...
  • Page 24: Smoke Odor

    Contact Maytag Customer Service at 1-800-788-8899 for further information concerning an Anode Replacement Kit and this Chlorination Treatment.
  • Page 25: High Temperature Shut Off System

    It is non-resettable. If the high temperature Shut-off condensation, loose connections, or the relief valve. activates, the gas control valve must be replaced. Call Maytag DO NOT replace the water heater until a full inspection of all Customer Service at 1-800-788-8899 for an authorized possible water sources is made and necessary corrective servicer.
  • Page 26: Troubleshooting Guide

    TROUBLESHOOTING GUIDE These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at 1-800-788-8899 for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product. Problem Cause Solution Improperly sealed, hot or cold supply connection, Tighten threaded connections.
  • Page 27: Notes

    NOTES...
  • Page 28 NOTES...
  • Page 29: Repair Parts List

    Now that you have purchased this gas water heater, should a need When ordering repair parts, always give the following information: ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an authorized servicer. Be sure to •...
  • Page 30 Now that you have purchased this gas water heater, should a need When ordering repair parts, always give the following information: ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an authorized servicer. Be sure to •...
  • Page 31 9003726 66001535 9003489 184382-001 66001536 9003491 66001806 9004021 66001537 9003492 66001812 9001595 66001538 9003493 66001822 9003539 66001540 9003495 66001823 9004024 66001544 9003501 66001827 9004016 66001547 9003530 66001828 9003538 66001549 9003541 66001828 9003538 66001550 9003542 TBD (to be determined by Maytag)
  • Page 32: Warranty

    This warranty is limited to the original owner of the water heater. TO RECEIVE WARRANTY SERVICE To locate an authorized service company in your area contact the Maytag dealer from whom your appliance was purchased; or call Maytag Customer Service at the number listed below. Should you not receive satisfactory...

Table of Contents