Chauvet Professional Maverick Storm Maverick Storm User Manual

3 beamwash
Table of Contents

Advertisement

Quick Links

User Manual
Model ID: MAVERICKSTORM3BEAMWASH-2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Maverick Storm Maverick Storm and is the answer not in the manual?

Questions and answers

Summary of Contents for Chauvet Professional Maverick Storm Maverick Storm

  • Page 1 User Manual Model ID: MAVERICKSTORM3BEAMWASH-2...
  • Page 2: Edition Notes

    Trademarks Chauvet, Chauvet Professional, the Chauvet logo, Maverick, and Maverick Storm 3 BeamWash are registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
  • Page 3: Table Of Contents

    Table of Contents TABLE OF CONTENTS 1. Before You Begin ............... What Is Included ................... Claims ......................Text Conventions ..................Symbols ......................Safety Notes....................FCC Statement of Compliance ..............RF Exposure Warning for North America and Australia........ Expected LED Lifespan................. 2.
  • Page 4 Table of Contents Dual Control Movement Values ................. 44 Dual Control Pixels Values................. 46 Color Chart......................53 Strobe Chart....................... 53 Control Chart...................... 54 Settings Configuration................... Pan Reverse ...................... 55 Tilt Reverse ......................55 Zoom Reverse....................55 Screen Reverse ....................55 Pan Angle......................
  • Page 5: Before You Begin

    Before You Begin 1. Before You Begin What Is Included • Maverick Storm 3 BeamWash • (2) 140 D Omega brackets with mounting hardware • Seetronic Powerkon IP65 power cable to bare wire • Quick Reference Guide Claims Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
  • Page 6: Safety Notes

    Before You Begin Safety Notes Read all the following safety notes before working with this product. These notes contain important information about the installation, usage, and maintenance of this product. This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians.
  • Page 7: Fcc Statement Of Compliance

    Before You Begin FCC Statement of Compliance This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.
  • Page 8: Introduction

    Introduction 2. Introduction Description The Maverick Storm 3 BeamWash creates new possibilities with two zones of zoom control. Both zones independently zoom from 4.6° to 53.6°, allowing beam and wash combinations from a single fixture. A 16- lens outer zone and 12-lens inner zone combine to deliver a 19,062 lumens output from 28 x 45W RGBW LEDs.
  • Page 9: Product Overview

    Introduction Product Overview Name Name LCD display DMX in/out Menu buttons USB port Carry handle Power in WDMX antenna Condensation port Ethernet port Fuse holder Maverick Storm 3 BeamWash User Manual Rev. 1...
  • Page 10: Product Dimensions

    Introduction Product Dimensions 18.9 in 480 mm 10 in 254 mm 16.1 in 409 mm 20.8 in 527 mm 7.2 in 183 mm 18.3 in 465 mm 14.5 in 368 mm 11.9 in 303 mm Maverick Storm 3 BeamWash User Manual Rev. 1...
  • Page 11: Setup

    Setup 3. Setup AC Power The Maverick Storm 3 BeamWash has an auto-ranging power supply, and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
  • Page 12: Signal Connections

    Setup Signal Connections The Maverick Storm 3 BeamWash can receive a DMX, Art-Net™, or sACN, signal. The Maverick Storm 3 BeamWash has two Amphenol XLRnet through ports and 5-pin DMX in and out ports. If using other compatible products with this product, it is possible to control each individually with a single controller.
  • Page 13: Connection Diagram

    Setup Connection Diagram Switch or Router Computer/ Controller (running Art-Net™ or sACN protocol) Maverick Storm 3 BeamWash To other Art-Net™ or sACN devices USB Software Update The Maverick Storm 3 BeamWash allows for software updates with a USB device using the built-in USB port.
  • Page 14: Operation

    Operation 4. Operation Control Panel Description Button Name Function <UP> Navigates upwards through the menu list or increases the value when in a function <MENU> Exits from the current menu or function <DOWN> Navigates downwards through the menu list or decreases the value when in a function <LEFT>...
  • Page 15: Menu Map

    Operation Menu Map Refer to the Maverick Storm 3 BeamWash product page on www.chauvetprofessional.com for the latest menu map. Programming Levels Description Control Settings Control Settings Main Level Basic Standard Advanced Tour Sets the DMX personality: Personality (see Control Personalities) Basic 2 Busk Basic 3...
  • Page 16 Operation Programming Levels Description Basic Sets the DMX personality: (see Personality Standard Control Personalities) Advanced Start Address 1–512 Sets the DMX starting address Basic Sets the Art-Net™ personality: Personality Standard (see Control Personalities) ArtNet Advanced Movement Start Address 1–512 Sets the Art-Net™ starting address Universe 0–255 Sets the Art-Net™...
  • Page 17 Operation Main Level Programming Levels Description Auto Test Auto test all functions Tilt P/T Speed Red1 Green1 Blue1 CTC1 Color1 Pattern1 LED Macro1 LED Ma. Speed1 LED Ma. Fade1 Background1 Background1 Dim. Dimmer1 Test Mode Shutter1 Manual Test Manually control and test all Red2 000–255 settings through the control panel...
  • Page 18 Operation Main Level Programming Levels Description Manual Manually set IP address IP Mode DHCP Network sets IP address Static Product sets IP address Network Setting _ _ _. _ _ _. _ _ _. Sets IP address in Manual mode _ _ _ _ _ _.
  • Page 19 Operation Main Level Programming Levels Description Sets red LED maximum value Green Sets green LED maximum value Color Balance 100–255 Blue Sets blue LED maximum value White Sets white LED maximum value Calibrated white balance Calibrated Uses maximum white values White Custom Uses custom white balance...
  • Page 20 Operation Main Level Programming Levels Description V_._ _ _ _ _ _ Shows firmware version Running Mode _ _ _ Shows current running mode Address _ _ _ Shows current starting address Shows current product Temperature _ _ _ temperature in °C Fixture Shows number of hours product Fixture Hours...
  • Page 21 Operation Main Level Programming Levels Description Frequency Pan Fine Tilt Tilt Fine P/T Speed Color Pattern LED Macro LED Ma. Speed LED Ma. Fade Background Background Dim. Big. Dim. Fine Dimmer Dimmer Fine Bg. Dim. Fine Dimmer Dimmer Fine Shutter Zoom1 Zoom2 Sys Info...
  • Page 22: Control Configuration

    Operation Control Configuration Use control configurations to operate the product with a DMX, WDMX, Art-Net™, Kling-Net, and sACN control signals. Control Mode The Maverick Storm 3 BeamWash works with wired DMX, WDMX, Art-Net™, Kling-Net, and sACN control signals. To select which single control protocol to use: 1.
  • Page 23: Starting Address

    Operation Starting Address Each product will respond to a unique starting address from the controller. All products with the same starting address will respond in unison. To set the starting address in Single Control mode: 1. Go to the Address Setting level. 2.
  • Page 24: Control Channel Assignments And Values

    Operation Control Channel Assignments and Values Pixel Chart Main 10 11 21 22 27 28 26 25 Ring Chart Ring Maverick Storm 3 BeamWash User Manual Rev. 1...
  • Page 25: Single Control Values

    Operation Single Control Values BK: Busk (20 channels) Channel Function Value Percent/Setting 000  255 0–100% 000  255 0–100% Tilt 000  255 0–100% Pan/tilt speed 000  255 0–100% Dimmer (main) 000  255 See Strobe (main) Strobe Chart 000 ...
  • Page 26 Operation B: Basic (32 channels), B2: Basic 2 (38 channels), B3: Basic 3 (38 channels) B3 Function Value Percent/Setting 000  255 0–100% 000  255 0–100% Pan fine 000  255 0–100% Tilt 000  255 0–100% Tilt fine 000 ...
  • Page 27 Operation B3 Function Value Percent/Setting 000  255 0–100% – – Green/magenta fine 000  255 0–100% – Blue/yellow 000  255 0–100% – – Blue/yellow fine 000  255 0–100% – White 000  255 0–100% – – White fine 000 ...
  • Page 28 Operation S: Standard (180 channels), A: Advanced (336 channels), T: Tour (416 channels), Function Value Percent/Setting 000  255 0–100% 000  255 0–100% Pan fine 000  255 0–100% Tilt 000  255 0–100% Tilt fine 000  255 0–100% Pan/tilt speed 000 ...
  • Page 29 Operation Function Value Percent/Setting 000  255 0–100% 35 Green/magenta (master) default to <000> 000  255 0–100% – 36 Green/magenta fine (master) default to <000> 000  255 0–100% 37 Blue/yellow (master) default to <000> 000  255 0–100% –...
  • Page 30 Operation Function Value Percent/Setting 000  255 0–100% – – 81 Dimmer 6 (ring) 000  255 0–100% – – 82 Dimmer 6 fine (ring) 000  255 0–100% 83 Red/cyan 6 (ring) 000  255 0–100% – 84 Red/cyan 6 fine (ring) 000 ...
  • Page 31 Operation Function Value Percent/Setting 000  255 0–100% 127 Blue/yellow 11 (ring) 000  255 0–100% – 128 Blue/yellow 11 fine (ring) 000  255 0–100% – – 129 Dimmer 12 (ring) 000  255 0–100% – – 130 Dimmer 12 fine (ring) 000 ...
  • Page 32 Operation Function Value Percent/Setting 000  255 0–100% 173 Blue/yellow 4 (main) 000  255 0–100% – 174 Blue/yellow 4 fine (main) 000  255 0–100% 175 White 4 (main) 000  255 0–100% – 176 White 4 fine (main) 000 ...
  • Page 33 Operation Function Value Percent/Setting 000  255 0–100% 219 Red/cyan 9 (main) 000  255 0–100% – 220 Red/cyan 9 fine (main) 000  255 0–100% 221 Green/magenta 9 (main) 000  255 0–100% – 222 Green/magenta 9 fine (main) 000 ...
  • Page 34 Operation Function Value Percent/Setting 000  255 0–100% 265 White 13 (main) 000  255 0–100% – 266 White 13 fine (main) 000  255 0–100% – – 267 Dimmer 14 (main) 000  255 0–100% – – 268 Dimmer 14 fine (main) 000 ...
  • Page 35 Operation Function Value Percent/Setting 000  255 0–100% 311 Green/magenta 18 (main) 000  255 0–100% – 312 Green/magenta 18 fine (main) 000  255 0–100% 313 Blue/yellow 18 (main) 000  255 0–100% – 314 Blue/yellow 18 fine (main) 000 ...
  • Page 36 Operation Function Value Percent/Setting 000  255 0–100% – – 357 Dimmer 23 (main) 000  255 0–100% – – 358 Dimmer 23 fine (main) 000  255 0–100% 359 Red/cyan 23 (main) 000  255 0–100% – 360 Red/cyan 23 fine (main) 000 ...
  • Page 37 Operation Function Value Percent/Setting 000  255 0–100% 403 Blue/yellow 27 (main) 000  255 0–100% – 404 Blue/yellow 27 fine (main) 000  255 0–100% 405 White 27 (main) 000  255 0–100% – 406 White 27 fine (main) 000 ...
  • Page 38 Operation PXL: Full Pixel (424 channels) Channel Function Value Percent/Setting 000  255 0–100% 000  255 0–100% Pan fine 000  255 0–100% Tilt 000  255 0–100% Tilt fine 000  255 0–100% Pan/tilt speed 000  255 Wide to narrow Zoom 1 000 ...
  • Page 39 Operation Channel Function Value Percent/Setting 000  255 See Strobe 5 (ring) Strobe Chart 000  255 0–100% Red/cyan 5 (ring) 000  255 0–100% Red/cyan 5 fine (ring) 000  255 0–100% Green/magenta 5 (ring) 000  255 0–100% Green/magenta 5 fine (ring) 000 ...
  • Page 40 Operation Channel Function Value Percent/Setting 000  255 0–100% Red/cyan 10 (ring) 000  255 0–100% Red/cyan 10 fine (ring) 000  255 0–100% Green/magenta 10 (ring) 000  255 0–100% Green/magenta 10 fine (ring) 000  255 0–100% Blue/yellow 10 (ring) 000 ...
  • Page 41 Operation Channel Function Value Percent/Setting 000  255 0–100% Dimmer 3 (main) 000  255 0–100% Dimmer 3 fine (main) 000  255 See Strobe 3 (main) Strobe Chart 000  255 0–100% Red/cyan 3 (main) 000  255 0–100% Red/cyan 3 fine (main) 000 ...
  • Page 42 Operation Channel Function Value Percent/Setting 000  255 See Strobe 7 (main) Strobe Chart 000  255 0–100% Red/cyan 7 (main) 000  255 0–100% Red/cyan 7 fine (main) 000  255 0–100% Green/magenta 7 (main) 000  255 0–100% Green/magenta 7 fine (main) 000 ...
  • Page 43 Operation Channel Function Value Percent/Setting 000  255 0–100% Red/cyan 11 fine (main) 000  255 0–100% Green/magenta 11 (main) 000  255 0–100% Green/magenta 11 fine (main) 000  255 0–100% Blue/yellow 11 (main) 000  255 0–100% Blue/yellow 11 fine (main) 000 ...
  • Page 44 Operation Channel Function Value Percent/Setting 000  255 0–100% Green/magenta 15 fine (main) 000  255 0–100% Blue/yellow 15 (main) 000  255 0–100% Blue/yellow 15 fine (main) 000  255 0–100% White 15 (main) 000  255 0–100% White 15 fine (main) 000 ...
  • Page 45 Operation Channel Function Value Percent/Setting 000  255 0–100% Blue/yellow 19 fine (main) 000  255 0–100% White 19 (main) 000  255 0–100% White 19 fine (main) 000  255 0–100% Dimmer 20(main) 000  255 0–100% Dimmer 20 fine (main) 000 ...
  • Page 46 Operation Channel Function Value Percent/Setting 000  255 0–100% White 23 fine (main) 000  255 0–100% Dimmer 24 (main) 000  255 0–100% Dimmer 24 fine (main) 000  255 See Strobe 24 (main) Strobe Chart 000  255 0–100% Red/cyan 24 (main) 000 ...
  • Page 47 Operation Channel Function Value Percent/Setting 000  255 0–100% Dimmer 28 fine (main) 000  255 See Strobe 28 (main) Strobe Chart 000  255 0–100% Red/cyan 28 (main) 000  255 0–100% Red/cyan 28 fine (main) 000  255 0–100% Green/magenta 28 (main) 000 ...
  • Page 48: Dual Control Movement Values

    Operation Dual Control Movement Values B: Basic (12 channels), S: Standard (35 channels), A: Advanced (46 channels) Function Value Percent/Setting 000  255 0–100% 000  255 0–100% Pan fine 000  255 0–100% Tilt 000  255 0–100% Tilt fine 000 ...
  • Page 49 Operation Function Value Percent/Setting 000  255 0–100% – Red/cyan (ring) 000  255 0–100% – – Red/cyan fine (ring) 000  255 0–100% – Red/cyan (main) 000  255 0–100% – – Red/cyan fine (main) 000  255 0–100% –...
  • Page 50: Dual Control Pixels Values

    Operation Dual Control Pixels Values B: Basic (120 channels), S: Standard (148 channels), A: Advanced (296 channels) Function Value Percent/Setting 000  255 0–100% Red/cyan 1 (ring) 000  255 0–100% – – Red/cyan 1 fine (ring) 000  255 0–100% Green/magenta 1 (ring) 000 ...
  • Page 51 Operation Function Value Percent/Setting 000  255 0–100% Green/magenta 8 (ring) 000  255 0–100% – – Green/magenta 8 fine (ring) 000  255 0–100% Blue/yellow 8 (ring) 000  255 0–100% – – Blue/yellow 8 fine (ring) 000  255 0–100% Red/cyan 9 (ring) 000 ...
  • Page 52 Operation Function Value Percent/Setting 000  255 0–100% Green/magenta 3 (main) 000  255 0–100% – – Green/magenta 3 fine (main) 000  255 0–100% Blue/yellow 3 (main) 000  255 0–100% – – Blue/yellow 3 fine (main) 000  255 0–100% –...
  • Page 53 Operation Function Value Percent/Setting 000  255 0–100% 137 Red/cyan 9 (main) 000  255 0–100% – – 138 Red/cyan 9 fine (main) 000  255 0–100% 139 Green/magenta 9 (main) 000  255 0–100% – – 140 Green/magenta 9 fine (main) 000 ...
  • Page 54 Operation Function Value Percent/Setting 000  255 0–100% – 183 White 14 (main) 000  255 0–100% – – 184 White 14 fine (main) 000  255 0–100% 185 Red/cyan 15 (main) 000  255 0–100% – – 186 Red/cyan 15 fine (main) 000 ...
  • Page 55 Operation Function Value Percent/Setting 000  255 0–100% 229 Blue/yellow 20 (main) 000  255 0–100% – – 230 Blue/yellow 20 fine (main) 000  255 0–100% – 231 White 20 (main) 000  255 0–100% – – 232 White 20 fine (main) 000 ...
  • Page 56 Operation Function Value Percent/Setting 000  255 0–100% 275 Green/magenta 26 (main) 000  255 0–100% – – 276 Green/magenta 26 fine (main) 000  255 0–100% 277 Blue/yellow 26 (main) 000  255 0–100% – – 278 Blue/yellow 26 fine (main) 000 ...
  • Page 57: Color Chart

    Operation Color Chart DMX Value Function Red Value Green Value Blue Value White Value No function 001  002 2700K R: 255 G: 175 B: 0 W: 50 003  004 3200K R: 243 G: 211 B: 0 W: 55 005 ...
  • Page 58: Control Chart

    Operation Control Chart DMX Value Function DMX Value Function 000  009 No function 115  119 Preset color HTP off 010  014 Blackout on pan/tilt 120  124 Fan mode ECO 015  019 Reserved for future use 125 ...
  • Page 59: Settings Configuration

    Operation Settings Configuration Pan Reverse To set the orientation of the pan: 1. Go to the Setup main level. 2. Select the Pan Reverse option. 3. Select from NO (normal pan motion), or YES (reversed pan motion). Tilt Reverse To set the orientation of the tilt: 1.
  • Page 60: Display Backlight Timer

    Operation Display Backlight Timer To set how long before an inactive display will turn off: 1. Go to the Setup main level. 2. Select the Backlight Timer option. 3. Select the length of the backlight timer, from 30S (30 seconds), 1M (1 minute), 5M (5 minutes), or ON (always on).
  • Page 61: White Balance

    Operation White Balance To set the custom white balance: 1. Go to the Setup main level. 2. Select the White Balance option. 3. Select from Red, Green, Blue, or White. 4. Select a value from 000–255. Merge Channel To merge the zoom functions: 1.
  • Page 62: Factory Reset

    Operation Factory Reset To reset the product to factory settings: 1. Go to the Settings main level. 2. Select the Factory Settings option. 3. Select NO (to cancel) or YES (to reset the product configuration). Test Mode Auto Test To have the Maverick Storm 3 BeamWash automatically test all functions one after the other: 1.
  • Page 63: Web Server

    Operation Web Server The Maverick Storm 3 BeamWash Web Server can be accessed by any computer on the same network as the product. It allows network access to system information, settings such as control setup, manual testing of all functions, firmware updates, and the ability to change the Web Server password. 1.
  • Page 64: Maintenance

    Allen Key screws head covers 25.5 22.1 Vacuum Test Measurements To ensure that the product has been reassembled correctly, use the IP Tester from Chauvet Professional to check the following data has the given measurements for the given method: Parameters Values...
  • Page 65: Transporting On Truss Or Racks

    Maintenance Transporting on Truss or Racks When transporting fixtures in pre-rigged truss and transportation racks, mount fixtures in the vertical position with the lenses facing down and the pan and tilt locks engaged. This is to prevent undue stress on the tilt locks and limit the amount of off-axis bounce on internal components.
  • Page 66: Technical Specifications

    Technical Specifications 6. Technical Specifications Dimensions and Weight Length Width Height Weight 18.98 in (482 mm) 11.93 in (303 mm) 23.74 in (603 mm) 82.45 lb (37.4 kg) Note: Dimensions in inches are rounded. Power Power Supply Type Range Voltage Selection Switching (internal) 100 to 240 VAC, 50/60 Hz Auto-ranging...
  • Page 67: Contact Us

    Contact Us Contact Us General Information Technical Support Chauvet World Headquarters Address: 3360 Davie Rd., Suite 509 Voice: (844) 393-7575 Davie, FL 33314 Fax: (954) 756-8015 Voice: (954) 577-4455 Email: chauvetcs@chauvetlighting.com Fax: (954) 929-5560 Toll Free: (800) 762-1084 Website: www.chauvetprofessional.com Chauvet U.K.

This manual is also suitable for:

Maverickstorm3beamwash-2

Table of Contents