BEFORE YOU BEGIN
- Always use a new 9V alkaline battery with an extended expiration date at least 3 years
beyond the current date. Connect the battery to the clip and match the direction to the image
inside of the battery cavity. Be sure not to pull on wires when disconnecting an old battery.
- This device is recommended for interior use only.
- If the device is used in a manner not specified here, the protection provided by the device
may be impaired.
- No part of this device may be replaced or repaired by anyone except the manufacturer.
TROUBLESHOOTING TIPS
SITUATION
False alarm sounds.
Detector does
not sound alarm
even when
touching water.
Detector does
not float.
Visit uk.zircon.com for the
most current instructions.
Leak Alert
Electronic Water Detector
LIKELY CAUSE
Battery charge is low.
Water detector is on a
conductive surface,
such as metal.
Ambient moisture has collected
on the Sensing Contacts.
Detector is positioned in a
way that water does not
touch Sensing Contacts.
Battery is dead.
Battery is not placed correctly in
the battery cavity.
+
™
SOLUTION
Change the battery.
Place a thin piece of paper or plastic between
detector and conductive surface.
Wipe Sensing Contacts dry.
Reposition the detector so Sensing Contacts
are flat against the surface where water
leakage might occur.
Install a new 9V alkaline battery with an
extended expiration date.
Position the battery per the battery installation
instructions in this document.