Hide thumbs Also See for 9000 Series:

Advertisement

ENGLISH – USER INSTRUCTIONS
9000 Series
Respirator
User
Instruction
Manual
IMPORTANT NOTICE TO USERS
You are responsible to understand and follow all warnings, restrictions and
other information contained in this instruction manual before you enter a
contaminated work area. Failure to do so may result in sickness or death.
MOLDEX-METRIC, INC.
10111 W. Jefferson Blvd., Culver City, CA 90232
Tel: +1 (800) 421-0668 or +1 (310) 837-6500
Fax: +1 (310) 837-9563
Email: sales@moldex.com www.moldex.com
MOLDEX TECHNICAL
SERVICE DEPARTMENT
+1 (800) 421-0668 or
+1 (310) 837-6500, ext. 512/550
Moldex and Ideas that wear well are registered trademarks.
U.S. Patents Pending. The PVC-Free logo is a trademark
of Moldex-Metric, Inc.
9000-710 REV B 4/10
CANADIAN CUSTOMER SERVICE
Tel: +1 (800) 421-0668, Ext. 517
Fax: +1 (310) 837-9563
BRAZIL – MOLDEX-METRIC LTDA
Av Ipiranga, 104, 22º Andar Sala 01
Sao Paulo, SP Brazil
Tel/Fax: +55 (11) 26 59 21 08
moldexbrazil@moldex.com
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Moldex 9000 Series

  • Page 1 Tel/Fax: +55 (11) 26 59 21 08 +1 (800) 421-0668 or moldexbrazil@moldex.com +1 (310) 837-6500, ext. 512/550 Moldex and Ideas that wear well are registered trademarks. U.S. Patents Pending. The PVC-Free logo is a trademark of Moldex-Metric, Inc. 9000-710 REV B 4/10...
  • Page 2 LIST OF PARTS FOR 9000 9001 – Small 9002 – Medium 9003 – Large Part # Description 0073-1 Inhale Diaphragm 0073-2 Exhale Diaphragm 0074 Cartridge Retainer Gasket 0092 Head Harness 0092 0094 Nose Cup M/L 0095 Nose Cup S LISTA DE PARTES PARA MODELO 9000 0073-1 9001-Pequeño 9002-Mediano 9003-Grande...
  • Page 3 , si usted percibe, de la Guía de selección o puede acc 10. Use cartuchos, filtros y máscaras faciales antes de la fecha espirar. www.moldex.com. impresa en la caja o en la bolsa. mpio, seco y no con- MÁSCARA Fig. 4...
  • Page 4 8) Check to see that it is seated and Applications. ” k the inhalation diaphragms for dirt properly. Moldex suggests tha OSHA. Moldex alway (shortest) breakthrou refer to OSHA’s web Fig. 5 advisor_genius_wo www.osha.gov/SLT...
  • Page 5: Filter Assembly

    Ubicación: variar considerablemente de la calculada usando estos mode- olo proporcionan estimados gruesos. Algunos datos que nece- los cartuchos Moldex para poder usar los modelos en el sitio INFORMACIÓN QUÍMICA (DE LA MSDS O DEL FABRICANTE) una absorción equivalente de 42.5 gramos de carbono para Fig.10...
  • Page 6 Harness #0092 – (Fig. 15) emove strap by pulling each of the 4 harness tabs through buckles and stall new strap with Moldex logo facing out and up. • This respirator must only be used for subst sert straps into buckles and tighten as needed.
  • Page 7 Moldex will be met by prod- ive Remedies: damages for the breach of this limited warranty replacement of such quantity of Moldex products proved to be factured.
  • Page 8 APPLICATIONS USE AGAINST 1. Contaminants specified on NIOSH approval label, matrix, cartridges or filters and in accordance with all limitations and applicable safety and health regulations, including OSHA. 2. Contaminants with good warning properties, i.e., smell, taste or irritation. DO NOT USE AGAINST 1.
  • Page 9: Niosh Cautions And Limitations

    Refer to User’s Instructions before donning. TECHNICAL SERVICE LINE Moldex maintains a toll-free Technical Service Line to answer questions about the use of Moldex respirators, contaminants and regulations. If you have any questions call +1 (800) 421-0668 or +1 (310) 837-6500, ext. 512/550 or...
  • Page 10: Selection Guide

    Refer to the NIOSH label for approval limitations. Call +1 (800) 421-0668 or +1 (310) 837-6500, ext. 512/550 for a copy of the selection guide or you may access via website at www.moldex.com. FACEPIECE ONLY...
  • Page 11 A qualitative fit test for up to 10x PEL, or quantitative, for up to 50x PEL must be performed before a respirator is assigned. Refer to current OSHA 29 CFR 1910.134 (f). Qualitative fit testing can be performed using the Moldex BITREX ®...
  • Page 12 It is the responsibility of the Safety Director or your supervisor to assist you in determining how tight the 9000 Series respirator should be on the users face. Prior to and during use the user has the final responsibility to determine how tight the respirator should be and when it needs to be adjusted to always maintain a proper seal.
  • Page 13: Change Out Schedules

    Be advised that actual service life can vary considerably from those calculated using these models. These models only provide rough esti- mates. Some of the data you will need specific to the Moldex cartridges in order to use the models on the OSHA website are: •...
  • Page 14 CARTRIDGE CHANGE OUT SCHEDULE WORKSHEET Duties / Job Classification: Location: CHEMICAL INFORMATION (FROM MSDS OR MANUFACTURER) Chemical: Exposure Limit: Maximum Concentration: Boiling Point: Molecular Weight: Liquid Density: Vapor Pressure: Molecular Polarization: Refractive Index: WORKSITE CONDITIONS Maximum Expected Temperature (ºC): Maximum Expected Relative Humidity (%): Work Rate: Number of Shifts/Week: Hours Cartridge Used/Shift:...
  • Page 15 FILTER DISKS FILTER DISK/PIGGYBACK ADAPTER/CARTRIDGE ASSEMBLY (Fig. 10) Before assembling filter disk #7940 to the piggyback adapter #7920, inspect the sealing surface, to make sure it is clean and undamaged and the gasket is in place. (Fig. 9) Push the piggyback adapter onto the cartridge until it snaps into place all around the cartridge.
  • Page 16: Maintenance

    Head Harness #0092 – (Fig. 15) • Remove strap by pulling each of the 4 harness tabs through buckles and discard. • Install new strap with Moldex logo facing out and up. • Insert straps into buckles and tighten as needed.
  • Page 17 These are Warnings and Limitations that all users must be made aware of in addi- tion to all warnings and other information on the outside of the Moldex respirator packaging or other published related information. You must read and comply with these Warnings and Limitations at all times and only when your employer has determined that it is appropriate to use this respirator.
  • Page 18: Limited Warranty

    The physical standards and specifications of Moldex will be met by prod- ucts sold. Exclusive Remedies: damages for the breach of this limited warranty are limited to the replacement of such quantity of Moldex products proved to be defectively manufactured. Except as provided above, Moldex shall not be liable or...

This manual is also suitable for:

900190029003

Table of Contents