The RMSSetDeviceInfo () is defined in the RMSCommon.axi include file.

Monitoring Source Usage

RMS can monitor source usage by using the RMSSrcUsageMod module.
RMSSrcUsageMod will track the amount of time, in minutes, a given source is
selected and logs this information to RMS when a new source is selected. This
information can be used to generate reports to determine the actual usage of a
device in a room.

Source Select

RMSSrcUsageMod monitors the selected source through
i!-ConnectLinx. i!-ConnectLinx includes 20 source selects in the standard
function list. Any standard source selected registered with i!-ConnectLinx will
automatically register in RMS by RMSSrcUsageMod. As your programming sets
the selected source on the i!-ConnectLinx device, RMSSrcUsageMod will track
the usage of the source and report it to RMS. To enable usage monitoring of a
standard i!-ConnectLinx source, simply register the source with i!-ConnectLinx
and add programming for the source select as if you were programming a button
from a touch panel:
DEFINE_EVENT
BUTTON_EVENT[vdvCLActions,1011]// VCR Select
{
PUSH:
{
// Switch the projector and switcher to select the VCR
PULSE[vdvCLActions,1011]
}
}
DATA_EVENT[vdvCLActions]
{
ONLINE:
{
// VCR Select
SEND_COMMAND vdvCLActions,"'ADD STD-1011'"
}
Additionally, you can add custom source to i!-ConnectLinx as custom actions.
Any custom action registered with i!-ConnectLinx that is named "Select ..." will
RMS NetLinx Programmer's Guide