Baud Rate Settings - AMX IRIS IRSERIAL DATA CAPTURE DEVICE Instruction Manual

Infrared/serial data capture unit
Table of Contents

Advertisement

Display Characters and P Modes (Cont.)
Characters
On
So
SP
P1-P2
P3
P4
P5
P6
P7
P8

Baud Rate Settings

The default communication setting for the IRIS unit is 9600 baud. You can change the baud rate
with the
rate of the PC running the IRLIB software program to store HC functions.
The IRIS unit automatically sets the baud rate to 9600 when you connect power. If
you reset the baud to any other setting and disconnect power, the previous baud rate
setting is lost and the IRIS unit will default back to 9600 baud.
To set the baud rate:
1. Disconnect the power supply from the IRIS unit.
2. Press and hold the
the pushbuttons.
3. The two digits that appear in the display represent the current baud rate setting. The following
table lists the RS-232 baud rates and corresponding display digits.
Baud Rate and Display Digits
300
600
1200
2400
4800
9600
4. Press the
5. Press and hold the
LED
IRIS Infrared/Serial Data Capture Unit
Description
P mode is on.
Send OK. HC function sent without errors to a PC running IRLIB.
Special Function. Special mode to capture unusual HC functions.
Not used.
Sends HC functions to a PC running IRLIB automatically after the VERIFY operation.
Disables the VERIFY operation to capture HC functions. Default mode requires the VERIFY
operation.
Loose-timing mode to capture JVC (PQ10956) HC functions.
Glitch-detection mode to capture Kinderman and some Mitsubishi HC functions.
Disables glitch-detection mode to capture non-carrier HC functions.
Strict-timing mode
,
, and
pushbuttons. You must set the IRIS unit's baud rate to match the baud
UP
DOWN
SEND
,
, and
UP
DOWN
03
06
12
24
48
96
or
pushbuttons to reset the baud rate.
UP
DOWN
,
, and
UP
DOWN
lights to indicate the IRIS unit is ready to capture an HC function.
pushbuttons. Reconnect the power supply and release
SEND
pushbuttons again to set the new baud rate. The
SEND
Installation
READY
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iris

Table of Contents