Capturing HC functions in SP mode

If you cannot capture an HC function in default mode, set the IRIS unit to special function (SP)
mode. Perform these steps to capture HC functions in SP mode:
1. Press and release the
appears in the display and the
2. Perform the Capturing HC functions in default mode steps 3 through 6 four times, or until the
SEND LED
3. Simultaneously press and release the
mode. The message nO (normal operation) briefly appears in the display to indicate default
mode is active.
All settings are returned to their default state when power is removed from the unit.

Capturing difficult HC functions using P3-P8 modes

Set the IRIS unit to the P3-P8 modes if you cannot capture an HC function in default or SP mode,
The P3 and P4 modes are special settings to capture HC functions. Perform these steps to capture
HC functions using P3-P8 modes:
1. Simultaneously press and release the
appears in the display. The IRIS unit is now in P mode.
2. Use the
in the following table.
3. Simultaneously press and release the
setting On and Off. The display then shows an On or Off message indicating the new P mode
setting and then immediately exits the P mode. You can activate multiple P modes to capture an
HC function; refer to the Default Mode Settings table on page 3 for the P mode default settings
when you connect power to the IRIS unit.
4. Repeat the Capturing HC functions in default mode steps 3 through 6, on page 3, to capture the
HC function.

Display Characters and P Mode Settings

The following table lists the display characters and P mode settings for special HC devices.
Display Characters and P Modes
Characters
[ ]
Er
Nd
NO
OF
4
and
UP
SEND
UP LED
lights, to capture the HC function. Then, go to the next step.
or
pushbutton to select the appropriate P modes according to the descriptions
UP
DOWN
Description
HC function is captured, analyzed, stored, and verified.
Error: HC function did not verify correctly.
No Device. Communication device error detected, or the IRLIB program is not staged to receive
HC functions.
Normal Operation. Ready to capture HC.
P mode is off.
pushbuttons at the same time. The message SP briefly
lights. The IRIS unit is now in SP mode.
and
pushbuttons to reset the IRIS unit to default
UP
SEND
,
, and
pushbuttons. The message P1
UP
DOWN
SEND
,
, and
pushbuttons to toggle the P mode
UP
DOWN
SEND
IRIS Infrared/Serial Data Capture Unit