Installation

Capturing HC Functions

The two modes you can use to capture HC functions are default and special function. You use
default mode, which is automatically set when you connect power to the IRIS unit, to capture the
majority of HC functions. The table below shows the IRIS unit settings for default mode. Before
capturing HC functions, make sure the baud rate in the IRIS unit is set properly, and connected to a
PC running the IRLIB Library Management Program. Refer to the IRLIB Library Management
Program instruction manual to store captured HC functions.
Default Mode Settings
Default
Baud
P3
P4
P5
P6
P7
P8

Capturing HC functions in default mode

To capture HC functions in default mode:
1. Make a list of the name and sequence of the HC functions you want to capture. The standard
order for HC functions is listed in the HC IR Functions section on page 6.
2. Connect the RS-232 cable to the DB-9 connector on the IRIS unit and the RS-232 port on your
PC, as shown in the Cables and Adapters section on page 6. Set the baud rate in the IRIS unit
to match the PC baud rate. Refer to the Baud Rate Settings section on page 5 to set the baud
rate. Then, connect the 12
unit. The
3. Hold the HC device approximately 3-inches away from the
the first key on the HC to capture the first function. The
the HC key as soon as the
4. The [ ] briefly appears in the display to indicate the HC function is captured. Then, 01 appears
and the
the Display Characters and P Modes table on page 4 for further information.
5. Hold the HC device approximately 3-inches away from the
the same key on the HC device again to verify the
IRIS unit. If the HC function is captured correctly, a pair of [ ] (brackets) will briefly flash in
the display. The
lights. If an Er message appears in the display, repeat steps 3 and 5. Otherwise, go to step 6.
6. Press the
software program.
7. Repeat steps 3 through 6 to capture all the HC functions on your list.
IRIS Infrared/Serial Data Capture Unit
Setting
9600
off
on
off
on
on
off
or 12
VDC
lights and 01 appears in the display.
READY LED
READY LED
and
s light. The
READY
VERIFY LED
goes off, 01 appears in the display, and the
VERIFY LED
pushbutton to send the captured HC function to the PC running the IRLIB
SEND
power supply to the 12
VAC
capture window. Press and hold
IR
SIGNAL LED
goes off.
will not light if P4 mode is active; refer to
LED
capture window. Press and hold
IR
function was captured correctly by the
IR
Installation
connector on the IRIS
VDC
will start blinking. Release
pushbutton's
SEND
LED
3