Cisco 675E Hardware Installation Manual page 29

Redundant power system
Table of Contents

Advertisement

Chapter 1
Product Overview
Table 1-1
LED
STANDBY/
ACTIVE
OUTPUT
PWR
TEMP
FAN
The six DC output LEDs display the status of the six output connectors that you
use to connect to supported devices. The output LEDs are numbered 1 to 6, which
corresponds to the numbers on the DC outputs.
the colors.
Table 1-2
Color
Off
Green
Blinking
green
78-15201-04
Status LEDs
Off
Green
The RPS 675
The RPS 675 is in
is not
active mode and
powered up.
available to
back-up a failed
device.
The RPS 675
The RPS 675
is not
internal power
powered up.
supplies are up and
running.
The RPS 675
The RPS 675
is not
internal
powered up.
temperature is in
the acceptable
range.
The RPS 675
The fan (blower) is
is not
running.
powered up.
DC Output LEDs
DC Output Status
No device is connected to the output connector.
A device is connected to the output connector.
The RPS is unavailable to the connected device. The RPS is
providing power to another connected device.
Cisco RPS 675 Redundant Power System Hardware Installation Guide
Front-Panel Description
Amber
(Blinking) The RPS is in
standby mode. You can
connect devices to the RPS,
and it does not attempt to
back them up until you
press the Standby/Active
button and place the RPS
into active mode.
The DC output power is not
functioning correctly.
The RPS 675 is approaching
an overtemperature
condition.
The blower is not operating
properly.
Table 1-2
lists the meanings of
1-5