Advertisement

Quick Links

modules CM PtP RS232 BA (6ES7540-1AD01-0AA0), CM PtP RS232 HF (6ES7541-
1AD01-0AB0)
SIMATIC
S7-1500 / ET 200MP
Communications modules
CM PtP RS232 BA
(6ES7540‑1AD01‑0AA0),
CM PtP RS232 HF
(6ES7541‑1AD01‑0AB0)
Equipment Manual
06/2024
A5E03777472-AB
Preface
S7-1500/ET 200MP
Documentation Guide
Product overview
Connecting
Configuring/address space
Programming
Interrupts/diagnostic
interrupts
Technical specifications
Dimensional drawing
1
2
3
4
5
6
7
A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CM PtP RS232 HF and is the answer not in the manual?

Questions and answers

Summary of Contents for Siemens CM PtP RS232 HF

  • Page 1 modules CM PtP RS232 BA (6ES7540-1AD01-0AA0), CM PtP RS232 HF (6ES7541- Preface 1AD01-0AB0) S7-1500/ET 200MP Documentation Guide SIMATIC Product overview Connecting S7-1500 / ET 200MP Communications modules CM PtP RS232 BA Configuring/address space (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF Programming (6ES7541‑1AD01‑0AB0) Interrupts/diagnostic interrupts Equipment Manual...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    ET 200MP. This equipment manual supplements the S7-1500 / ET 200MP Automation system (http://support.automation.siemens.com/WW/view/en/59191792) system manual. You can find functions generally relating to the S7-1500 or the ET 200MP in the S7-1500 / ET 200MP Automation system manual.
  • Page 4: Security Information

    Siemens accepts no liability for the use of the open source software over and above the intended program sequence, or for any faults caused by modifications to the software.
  • Page 5: Table Of Contents

    Table of contents Preface ..............................3 S7-1500/ET 200MP Documentation Guide ..................... 6 S7-1500 / ET 200MP Documentation Guide ................6 SIMATIC Technical Documentation ..................8 Tool support ........................10 Product overview ..........................11 Properties .......................... 11 Functions........................... 14 Properties of the RS232 interface ..................15 Connecting............................
  • Page 6: S7-1500/Et 200Mp Documentation Guide

    S7-1500/ET 200MP Documentation Guide S7-1500 / ET 200MP Documentation Guide The documentation for the SIMATIC S7-1500 automation system and the ET 200MP distributed I/O system is arranged into three areas. This arrangement enables you to access the specific content you require. Changes and supplements to the manuals are documented in a Product Information.
  • Page 7: General Information

    Internet (https://support.industry.siemens.com/cs/de/en/view/68052815). Manual Collection S7-1500/ET 200MP The Manual Collection contains the complete documentation on the SIMATIC S7-1500 automation system and the ET 200MP distributed I/O system gathered together in one file. You can find the Manual Collection on the Internet.
  • Page 8: Simatic Technical Documentation

    Industry Online Support International (https://support.industry.siemens.com/cs/ww/en/view/109742705) Watch this short video to find out where you can find the overview directly in Siemens Indus- try Online Support and how to use Siemens Industry Online Support on your mobile device: Quick introduction to the technical documentation of automation products per video (https://support.industry.siemens.com/cs/us/en/view/109780491)
  • Page 9: Application Examples

    Manuals, characteristics, operating manuals, certificates • Product master data You can find "mySupport" on the Internet. (https://support.industry.siemens.com/My/ww/en) Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products.
  • Page 10: Tool Support

    (https://support.industry.siemens.com/cs/ww/en/view/109767888) SINETPLAN SINETPLAN, the Siemens Network Planner, supports you in planning automation systems and networks based on PROFINET. The tool facilitates professional and predictive dimensioning of your PROFINET installation as early as in the planning stage. In addition, SINETPLAN supports you during network optimization and helps you to exploit network resources optimally and to plan reserves.
  • Page 11: Product Overview

    Product overview Properties Article numbers CM PtP RS232 BA CM PtP RS232 HF Article number 6ES7540-1AD01-0AA0 6ES7541-1AD01-0AB0 Note The CM PtP module with the article The CM PtP module with the article number 6ES7540-1AD01-0AA0 is a number 6ES7541-1AD01-0AB0 is a compatible replacement for the CM PtP compatible replacement for the CM PtP with article number 6ES7540-1AD00-...
  • Page 12 Product overview 2.1 Properties View of the module ① Module type and designation ② Article number ③ LEDs for RS232 interface ④ 9-pin D-sub male plug ⑤ LEDs for diagnostics Figure 2-1 View of the CM PtP RS232 BA/HF module as an example Properties The communications module has the following properties: •...
  • Page 13: Other Components

    You can find additional information on the connecting cables for a point-to-point connection between the communications module and communication partner CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093) in section 3 of the function manual. Additional information You can find additional information on the properties of the CM PtP in the function manual CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093).
  • Page 14: Functions

    You can find information on the configuration and programming of the communications module in the function manual CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093) and in the information system of STEP 7 (TIA Portal). Communications modules CM PtP RS232 BA (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF (6ES7541‑1AD01‑0AB0)
  • Page 15: Properties Of The Rs232 Interface

    Product overview 2.3 Properties of the RS232 interface Properties of the RS232 interface Definition The RS232 interface is a voltage interface used for serial data transmission. Properties The RS232 interface has the following properties and meets the following requirements: Type: Voltage interface Front connector: 9-pin sub-D male plug with screw lock (assignment see RS232 interface...
  • Page 16: Connecting

    Connecting RS232 interface of the communications module The RS232 interface is a voltage interface used for serial data transmission. The inputs and outputs are not isolated from each other. The inputs and outputs are electrically isolated from the backplane bus. Terminal assignment Connect the connecting cable to the 9-pin sub-D male plug behind the front flap of the communications module.
  • Page 17: Installation Guidelines

    Ensure the power supply is disconnected before you wire the communications module. Additional information You can find information on connecting the modules in the S7-1500 / ET 200MP Automation system (http://support.automation.siemens.com/WW/view/en/59191792) system manual. Installation guidelines To take into consideration The general installation guidelines must be taken into consideration (see the EMC/EMI compatible installation of control systems (http://support.automation.siemens.com/WW/view/en/59193566) Function Manual).
  • Page 18: Configuring/Address Space

    Information on using the communications module in a third-party system is available in the programming and operating manual CM PtP in operation without SIMATIC system instructions (http://support.automation.siemens.com/WW/view/en/59062563). Communications modules CM PtP RS232 BA (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF (6ES7541‑1AD01‑0AB0) Equipment Manual, 06/2024, A5E03777472-AB...
  • Page 19 The respective GSD file for the ET 200MP distributed I/O system is available for download on the Internet: • GSD file PROFINET IO (https://support.industry.siemens.com/cs/ww/en/view/68189683) • GSD file PROFIBUS DP (https://support.industry.siemens.com/cs/ww/en/view/80206700) Communications modules CM PtP RS232 BA (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF (6ES7541‑1AD01‑0AB0)
  • Page 20: Parameter Setting

    Configuring/address space 4.2 Parameter setting Parameter setting You can use various parameters to define the properties of the communications module. Depending on the settings, not all parameters are available. You set the parameters of the module as follows: Parameter setting via ... Basic procedure Hardware configuration in STEP 7 1.
  • Page 21 Configuring/address space 4.2 Parameter setting Parameters of the CM PtP RS232 BA/HF for Freeport protocol The following parameter settings are possible when you select the "Freeport" protocol. The default settings of the parameters are shown in bold in the "Value range" column. Table 4- 1 Programmable parameters Parameter...
  • Page 22 Configuring/address space 4.2 Parameter setting Parameter Value range Diagnostics Activate break detection Deactivated • • Activated Enable diagnostics interrupt • Deactivated Activated • Configuration of message sending: Frame default settings Send break before frame start Deactivated • • Activated Break duration 0...12...65535 bit times Send idle line •...
  • Page 23 Configuring/address space 4.2 Parameter setting Parameter Value range Number of sequences to be de- • fined • • • Check this character • Deactivated • Activated Character (HEX) 0...FF Configuration of message reception: Frame end identifier Recognize message end by mes- Deactivated •...
  • Page 24 Configuring/address space 4.2 Parameter setting Parameter Value range 0...255 bytes Number of characters not count- ed in length specification After receipt of an end sequence Deactivated • • Activated Check this character • Deactivated • Activated Character (HEX) 0...FF Configuration of message reception: Receive buffer Buffered received frames 1...255 Prevent overwriting...
  • Page 25 Configuring/address space 4.2 Parameter setting Parameters of the CM PtP RS232 BA/HF for 3964(R) protocol The following parameter settings are possible when you select protocol "3964(R)". The default settings of the parameters are shown in bold in the "Value range" column. Table 4- 2 Programmable parameters Parameter...
  • Page 26 Configuring/address space 4.2 Parameter setting Parameter Value range 3964(R) configuration Priority High • • With block check (3964R) • Deactivated Activated • Use default values • Deactivated • Activated Connection attempts 1...6...255 Transmission attempts 1...6...255 Character delay time 20...220...65535 ms Acknowledgment delay 20...2000...65535 ms When configuring with GSD file, you specify the option by selecting the module name in the...
  • Page 27: Address Space

    The equipment manual of the communications module is supplemented by the function manual CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093) and the STEP 7 (TIA Portal) information system. There you will find information on the following topics: • Operating modes •...
  • Page 28: Programming

    Programming Data communication You define the type of data exchange with the "Performance optimized for many short frames" parameter of the module in the hardware configuration (Page 20). It is recommended to use the option for performance optimization, provided that the maximum length for incoming/outgoing frames is not exceeded.
  • Page 29 Additional information on programming the communications modules is available in the function manual CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093) and in the STEP 7 (TIA Portal) information system. Communications modules CM PtP RS232 BA (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF (6ES7541‑1AD01‑0AB0)
  • Page 30: Interrupts/Diagnostic Interrupts

    Interrupts/diagnostic interrupts Status and error displays LED displays of the communications module The figure below shows the LED displays (status and fault displays) of the CM PtP RS232 BA/HF with open front flap. ① RUN (green) ② ERROR (red) ③ MAINT (yellow) ④...
  • Page 31 Replace the communications module. Flashes Flashes Flashes Information on startup and diagnostics of the communications module is available in the CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093) function manual. Table 6- 2 Status displays TXD/RXD LEDs Meaning Interface is transmitting...
  • Page 32: Diagnostic Alarms

    0 and 1. For the structure of the data records, refer to the equipment manual for the IM 155-5 DP ST interface module, which is available for download on the Internet (https://support.industry.siemens.com/cs/ww/de/view/78324181). Communications modules CM PtP RS232 BA (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF (6ES7541‑1AD01‑0AB0)
  • Page 33: Diagnostic Messages

    Information on the configuration of the data record can be found in the function manual CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093) (Edition 2024). Communications modules CM PtP RS232 BA (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF (6ES7541‑1AD01‑0AB0) Equipment Manual, 06/2024, A5E03777472-AB...
  • Page 34: Technical Specifications

    Technical specifications The following table shows the technical specifications as of the issue date. You can find a data sheet with up-to-date technical specifications on the Internet. • CM PtP RS232 BA (https://support.industry.siemens.com/cs/de/en/pv/6ES7540-1AD01-0AA0/td?dl=en) • CM PtP RS232 HF (https://support.industry.siemens.com/cs/de/en/pv/6ES7541-1AD01-0AB0/td?dl=en) Article number...
  • Page 35 Technical specifications Article number 6ES7540-1AD01-0AA0 6ES7541-1AD01-0AB0 Interface types RS 232 19.2 kbit/s 115.2 kbit/s • Transmission rate, max. 15 m 15 m • Cable length, max. RTS, CTS, DTR, DSR, RI, DCD RTS, CTS, DTR, DSR, RI, DCD • RS 232 auxiliary signals Protocols Integrated protocols Freeport...
  • Page 36 Weights Weight, approx. 0.22 kg 0.22 kg Additional general technical specifications for SIMATIC S7-1500 are available in the system manual S7 -1500 Automation System (http://support.automation.siemens.com/WW/view/en/59191792). Communications modules CM PtP RS232 BA (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF (6ES7541‑1AD01‑0AB0) Equipment Manual, 06/2024, A5E03777472-AB...
  • Page 37: Dimensional Drawing

    Dimensional drawing The following figures show the dimension drawing of the module on the mounting rail, as well as a dimension drawing with open front flap. Always observe the specified dimensions for installation in cabinets, control rooms, etc. Figure A-1 Dimensional drawing of the communications module CM PtP RS232 BA/HF with front and side view Communications modules CM PtP RS232 BA (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF (6ES7541‑1AD01‑0AB0) Equipment Manual, 06/2024, A5E03777472-AB...
  • Page 38 Dimensional drawing Figure A-2 Dimension drawing of the CM PtP RS232 BA/HF module, side view with open front flap Communications modules CM PtP RS232 BA (6ES7540‑1AD01‑0AA0), CM PtP RS232 HF (6ES7541‑1AD01‑0AB0) Equipment Manual, 06/2024, A5E03777472-AB...