Table of Contents

Advertisement

MANUAL ENGLISH
for devices of the Impact67 PN series
Art.-No. 55130 | 55131 | 55132

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 55130 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
Service and support
Information on sales, system advisors, and customer service center.
Scope of delivery
Details the items included in the product package.
Applicable documents
Lists documents relevant to the product, available online.
Environmentally friendly disposal
Guidelines for proper disposal of devices and packaging according to regulations.
About this manual
Describes the manual's scope, hardware/firmware, information provided, and purpose.
Symbols
Explains the meaning of various symbols used for safety and notes within the document.
For your safety
General safety instructions
Outlines electrical safety rules, qualified personnel, and target group for the manual.
Intended purpose
Describes the intended use of the Impact67 device in harsh industrial environments.
Foreseeable misuse
Lists warnings and actions to avoid regarding misuse of the device.
Description
Device
Describes the Impact67 as a robust, encapsulated fieldbus device suitable for rough environments.
Device overview
Provides an overview of the Impact67 device variants, highlighting ports and features.
Structure of the device designation
Explains the naming convention and structure used to designate the product's function and channels.
Device structure
Illustrates the physical layout of the device, identifying ports and components.
Connections
Details the various connection types and their configurations.
Pin assignment
Details the pin assignments for various connectors (M12, 7/8").
Display elements
Describes the function of the LEDs on the device for status indication.
DIP switch settings
Explains the function of the DIP switches for device configuration and operating modes.
IO-Link
Explains what IO-Link is and its role in connecting devices to automation systems.
Data storage
Details the data storage feature for IO-Link devices, aiding in device replacement without reconfiguration.
PROFINET IO
Explains PROFINET IO as an open communication protocol based on Ethernet.
PROFINET IO Communication
Explains PROFINET IO as an open communication protocol based on Ethernet.
Structure of the conformance classes
Describes the PROFINET IO conformance classes (CC-A, CC-B, CC-C) and their functions.
PROFIenergy
Introduces PROFIenergy as a profile for managing energy savings in production networks.
Shared Device (SD)
Explains the Shared Device function, enabling access to an IO device from two IO controllers.
Isochronous Real Time (IRT)
Describes the IRT concept for synchronized data exchange in PROFINET for precise timing.
Media redundancy (MRP)
Explains the Media Redundancy Protocol (MRP) for ensuring network line availability.
Simple Network Management Protocol (SNMP)
Explains SNMP as a protocol for monitoring and managing network components.
Technical Data
Art.-No. 55130 Impact67 PN DIO16 IRT
Technical specifications for the Impact67 PN DIO16 IRT device.
Electrical data
Details electrical specifications, including bus data, supply, and I/O characteristics.
Environmental characteristics
Lists climatic, mechanical, and electrical safety specifications like operating temperature and protection class.
Protection
Describes device protection mechanisms like overvoltage and short circuit protection.
Mechanical data
Provides mechanical specifications such as housing material, dimensions, and weight.
Product reliability
Presents product reliability data, including MTTF (Mean Time To Failure).
Conformity, Approvals
Lists product standards, certifications (CE, UKCA), and RoHS compliance details.
Art.-No. 55131 Impact67 PN DIO14 IOL2 IRT
Technical specifications for the Impact67 PN DIO14 IOL2 IRT device.
Electrical data
Details electrical specifications for the 55131 model, including bus data and supply.
Environmental characteristics
Lists environmental specifications for the 55131 model, covering climatic and mechanical aspects.
Protection
Details protection mechanisms for the 55131 device.
Mechanical data
Provides mechanical data for the 55131 model, including dimensions and weight.
Product reliability
Lists product reliability data for the 55131 model.
Conformity, Approvals
Lists conformity and approval information for the 55131 model.
Art.-No. 55132 Impact67 PN DIO12 IOL4 IRT
Technical specifications for the Impact67 PN DIO12 IOL4 IRT device.
Electrical data
Details electrical specifications for the 55132 model, covering bus data and supply.
Environmental characteristics
Lists environmental specifications for the 55132 model, including climatic and mechanical data.
Protection
Details protection mechanisms for the 55132 device.
Mechanical data
Provides mechanical data for the 55132 model, including dimensions and weight.
Product reliability
Lists product reliability data for the 55132 model.
Conformity, Approvals
Lists conformity and approval information for the 55132 model.
Mounting
Requirements
Outlines the necessary conditions for mounting the device, such as surface and grounding.
Dimensions
Provides detailed dimensional drawings of the device.
Mounting distance
Specifies the recommended minimum distance between mounted devices for proper installation and heat dissipation.
Mounting the device
Provides instructions on how to physically attach the device.
Fasten device
Provides step-by-step instructions and torque specifications for physically fastening the device.
Functional ground
Explains how to attach the grounding strap for proper functional grounding.
Installation
Electrical Installation of the device
Covers critical safety warnings for electrical installation, including high voltage and fire risks.
Sensors and actuators
Explains how to connect sensors and actuators using M12 ports and provides torque specifications.
Connecting the Ethernet bus
Details the connection process for the Ethernet bus using M12 ports and provides torque.
Power supply connection
Explains how to connect the power supply using 7/8" connectors and provides torque.
Ensuring Tightness (IP67)
Describes how to ensure the device's IP67 tightness by sealing ports and connecting cables properly.
Start-up
Loading GSDML Files
Explains how to install GSDML files or device description files for configuration.
Configuration and parameterization
Module configuration
Explains how to paste and configure individual IO-Link ports and virtual modules in the hardware catalog.
Basic configuration
Describes the basic configuration of devices in TIA portal for different Art.-Nos.
Basic configuration with submodules for diagnostic
Explains basic configuration with submodules for diagnostic information in TIA portal.
Module configuration addresses
Explains how I/O addresses are assigned based on address allocation once the IO-Master is allocated.
IO-Link master
Describes the IO-Link master's capability for managing IO-Link ports and submodules.
IO-Link state
Explains read-only access to IO-Link devices/ports via IO-Link state submodules.
State
Details read-only access to digital IOs and system status via State submodules.
Parameterization
Explains the various options available for parameterizing device functions.
Device parameters
Lists and describes parameters for configuring device diagnostics, thresholds, and tool options.
Diagnostic parameters
Explains how to configure diagnostic reports, including global and device-specific reporting options.
Tool parameters
Covers enabling or disabling access via the Murrelektronik IO-Link device tool.
General parameters
Details general parameters like pin/port-based IO layout and input delay settings.
System state IO layout
Shows the system status IO layout in decimal and hexadecimal formats for diagnostics.
IO-Link port parameters
Details parameters for IO-Link ports, including diagnostics, port configuration, and validation/backup settings.
IO-Link event integration
Explains the allocation of IO-Link events to PROFINET diagnostics based on integration type.
Notifications from the device
Describes how to process IO-Link events of the "Notification" type, either discarding or generating alarms.
Port cycle time
Explains how to set port cycle times for communication between IO-Link master and device.
Validation & backup
Details validation and backup options for device verification and data storage management.
IO-Link device parameterization
Explains the various methods for configuring and parameterizing IO-Link devices.
IO-Link configuration
Outlines methods for configuring IO-Link devices.
Cyclic and acyclic communication
Explains cyclic and acyclic data exchange types in IO-Link communication.
Acyclic IO-Link access
Describes acyclic access to data areas using PN-IO read/write services and function blocks.
I&M data
Details I&M data records for identifying devices and storing system-specific information.
IO-Link device function block
Describes the IO-LINK_DEVICE function block in TIA Portal for parameterization and diagnostics.
Basic setting
Covers initial setup steps for device identification and network configuration.
Identification of the individual devices in the network
Explains how to identify devices using MAC address and device type in the network.
Assign the PROFINET device name
Details how to assign a name to a PROFINET device after identification.
Temporary IP address
Describes how to assign a temporary IP address and subnet mask to the device.
PROFINET topology
Explains how to configure the network topology and perform automatic topology recognition.
Setting the topology
Explains how to set the PROFINET topology and perform automatic topology recognition.
Fast-Start-Up (FSU) configuration
Covers configuration for optimizing device startup and runtime characteristics.
Activation of the prioritized startup
Describes how to activate the prioritized startup feature for Fast Start-Up functionality.
Parameter setting on the bus connections
Details setting transmission rate/duplex and disabling autonegotiation for FSU.
Media redundancy (MRP) configuration
Explains configuration for network line availability and redundancy.
Setting up the MPR manager
Explains how to set up the MPR manager for a PROFINET-managed switch.
Setting up an MRP client
Describes how to configure an Impact67 device as an MRP client in the network.
Setting up the MRP cycle times
Details parameterizing IO cycle times for devices based on MRP master requirements.
Setting up an MRP domain
Explains how to set up an MRP domain in TIA Portal for managing ring configurations.
Isochronous real time (IRT) configuration
Explains configuration for synchronized data exchange and precise timing.
IRT communication: Setting up the Sync master
Details how to configure the PLC as a Sync master for IRT communication.
IRT communication: Setting up the Sync slave
Explains how to configure the Impact67 device as a Sync slave for IRT communication.
Shared Device (SD) configuration
Explains configuration for accessing an IO device from multiple IO controllers.
Creating project 1
Describes the first project setup for configuring Shared Device access.
Creating project 2
Details the second project setup required for configuring Shared Device access.
PROFIenergy configuration
Explains the PROFIenergy functions and the two energy-saving modes supported by the device.
PROFIenergy
Explains the PROFIenergy functions and the two energy-saving modes supported by the device.
SNMP
Explains SNMP as a protocol for monitoring and managing network components.
Sending an SNMP request
Explains how to send an SNMP message and the structure of the device's response.
Factory settings
Details procedures for resetting the device to its factory default state.
Reset to factory settings - retain I&M data
Details the procedure for resetting the device to factory settings while retaining I&M data.
Reset to factory settings - delete I&M data
Explains how to reset the device to factory settings and delete I&M data.
Operation
LED indication
Explains the arrangement and functions of the LEDs for inputs, outputs, bus, and power.
Extended LED indication
Provides extended LED indications for PROFIenergy modes, device identification, and firmware updates.
PROFINET Diagnostics
Explains how the device reports diagnostic information as alarms based on PROFINET specification.
General diagnostic messages
Lists general diagnostic messages, their meanings, and recommended actions for troubleshooting.
General diagnostic messages at IO-Link ports
Details diagnostic messages specific to IO-Link ports, including IODD errors, meanings, and actions.
Diagnostic messages at IO-Link ports
Lists diagnostics for IO-Link ports based on integration guidelines.
According to IO-Link integration guideline Edition 1
Lists diagnostics for IO-Link ports based on the integration guideline, including error codes and actions.
Murrelektronik IO-Link - Integration and extended integration
Explains diagnostics for Murrelektronik IO-Link integration and extended integration, including value ranges and master events.
Maintenance and cleaning
Software update
Details the process for updating the device firmware using the AutoUpdateX V3 software.
Recovery Firmware
Explains how to recover or install firmware in case of a damaged firmware image.
Appendix
Accessories
Lists related products and accessories for the device.
Tools
Lists recommended tools for installation and maintenance, like screwdrivers and torque wrenches.
Glossary
Provides a glossary of terms used in the manual, defining technical acronyms and concepts.
Legal notes
Disclaimer
Contains a disclaimer regarding the accuracy and warranty of the technical documentation.

Table of Contents

Save PDF