● Products described in this Document, which may include licenses obtained from third parties. Any part of the Document, including text, pictures, graphics, etc., belongs to Hikvision. No part ● of this Document may be excerpted, copied, translated, or modified in whole or in part by any means without written permission.
Page 3
DS-KD8003 Series Module Door Station User Manual PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY ● RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS;...
DS-KD8003 Series Module Door Station User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could Danger result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could Caution result in equipment damage, data loss, performance degradation, or...
DS-KD8003 Series Module Door Station User Manual Regulatory Information EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union.
Page 6
DS-KD8003 Series Module Door Station User Manual Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité...
DS-KD8003 Series Module Door Station User Manual Contents Chapter 1 Appearance ........................ 1 Chapter 2 Configure Sub Module Address ................... 8 Chapter 3 Terminal and Wiring ....................10 3.1 Cable and Transmission Distance ..................10 3.2 Terminal Description ......................10 3.3 Module Door Station Wiring ....................
Page 8
DS-KD8003 Series Module Door Station User Manual 6.2 Live View ..........................74 6.3 Person Management ......................75 6.4 Device Management ......................77 6.5 Remote Configuration ......................78 6.5.1 Local Parameters Settings ................... 78 6.5.2 View Device Information ..................... 79 6.5.3 Set Time ........................79 6.5.4 Set DST ........................
DS-KD8003 Series Module Door Station User Manual Chapter 1 Appearance Main Unit Main Unit (with Button) Figure 1-1 Main Unit (with Button) Appearance Table 1-1 Appearance Description Description Microphone Low Illumination IR Supplement Light...
Page 10
DS-KD8003 Series Module Door Station User Manual Description Built-in Camera Loudspeaker Call Button Nametag TAMPER Network Interface Module- C onnecting Interface (output) Terminals Main Unit (without Button)
Page 11
DS-KD8003 Series Module Door Station User Manual Figure 1-2 Main Unit (without Button) Appearance Table 1-2 Appearance Description Description Microphone Low Illumination IR Supplement Light Built-in Camera Loudspeaker TAMPER Network Interface...
Page 12
DS-KD8003 Series Module Door Station User Manual Description Module- C onnecting Interface (Output) Terminals Note Nametag area supports insert customized name card. The suggested card size is: 58 (L) x ● 11.7(W) mm. The module connecting interface is used to connect other function module, such as nametag ●...
Page 13
DS-KD8003 Series Module Door Station User Manual Figure 1-3 Two-Wire Main Unit (with Button) Appearance Table 1-3 Appearance Description Description Microphone Low Illumination IR Supplement Light Built-in Camera Loudspeaker Call Button Nametag TAMPER...
Page 14
DS-KD8003 Series Module Door Station User Manual Description Two-Wire Interface (24 VDC Power Input) Module- C onnecting Interface (output) Terminals Two-Wire Main Unit (without Button) Figure 1-4 Two-Wire Main Unit (without Button) Appearance Table 1-4 Appearance Description Description Microphone Low Illumination IR Supplement Light Built-in Camera...
Page 15
DS-KD8003 Series Module Door Station User Manual Description Loudspeaker TAMPER Two-Wire Interface (24 VDC Power Input) Module- C onnecting Interface (output) Terminals Note Nametag area supports insert customized name card. The suggested card size is: 58 (L) x ● 11.7(W) mm. The module connecting interface is used to connect other function module, such as nametag ●...
DS-KD8003 Series Module Door Station User Manual Chapter 2 Configure Sub Module Address You need to set the sub module address via DIP switch before installation. Steps 1. Remove the rubber cover on the rear panel of the sub module to expose the DIP switch. Figure 2-1 DIP Switch 2.
Page 17
DS-KD8003 Series Module Door Station User Manual DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 Module Address Module 6 Module 7 Module 8...
DS-KD8003 Series Module Door Station User Manual Chapter 3 Terminal and Wiring 3.1 Cable and Transmission Distance Cable and transmission distance between devices should follow rules below. Table 3-1 Cable and Transmission Distance Cable Indoor Indoor Type KAD7060E KAD7060E KAD7061E KAD7061E Station to KAD7060...
Page 19
DS-KD8003 Series Module Door Station User Manual Main Unit Terminals Figure 3-1 Main Unit Terminals Table 3-2 Descriptions of Terminals and Interfaces Interface Description Door Lock Relay Output (NC) Door Lock Relay Output (NO) Common Interface Door Lock Relay Output (NC) Door Lock Relay Output (NO) Grounding 12 V IN/OUT1...
Page 20
DS-KD8003 Series Module Door Station User Manual Interface Description 12 V OUT2 PoE Network Interface(Supports IEEE 802.3af) Table 3-3 Power Supply Power Supply Door Station Power Output PoE (802.3af) DC 12V OUT1/DC 12V OUT2 6 W MAX in total DC 12 V DC 12V OUT2 18 W MAX Two-Wire Main Unit Terminal...
Page 21
DS-KD8003 Series Module Door Station User Manual Interface Description Grounding 12 V IN/OUT1 The power output is 12 V, 500mA. Grounding AIN2 For the access of Door Magnetic 2 AIN1 For the access of Door Magnetic 1 AIN3 For the access of Exit Button 1 AIN4 For the access of Exit Button 2 485-...
Page 22
DS-KD8003 Series Module Door Station User Manual Sub Module Terminal (Except Touch-Display Module) Figure 3-3 Sub Module Terminal (Except Touch-Display Module) Table 3-6 Description Interface Description 485- Module- C onnecting Interface (Input) 485+ 12V IN 485- Module- C onnecting Interface (Output) 485+ 12V OUT...
Page 23
DS-KD8003 Series Module Door Station User Manual Touch-Display Module Figure 3-4 Touch-Display Module Table 3-7 Description Interface Description 485- Module- C onnecting Interface (Input) 485+ 12V IN 485- Module- C onnecting Interface (Output) 485+ 12V OUT Grounding Interface CVSB IN Composite Video Broadcast Signal Input (Reserved) LINEOUT- Audio Output (Reserved)
DS-KD8003 Series Module Door Station User Manual 3.3.2 Door Contact Wiring Figure 3-6 Door Contact Wiring Note AIN1 and AIN2 are defaulted to connect door contact. Door contact connected to AIN1 detects status of the lock that connected to NC1/NO1; Door contact connected to AIN2 detects the status of the lock connected to NC2/NO2.
DS-KD8003 Series Module Door Station User Manual 3.3.3 Exit Button Wiring Figure 3-7 Exit Button Wiring Note AIN3 and AIN4 are set as default for connecting exit button. Exit button connected to AIN3 opens the lock connected to NC1/NO1; Exit button connected to AIN4 controls the lock that connected to NC2/NO2.
DS-KD8003 Series Module Door Station User Manual Chapter 4 Installation Note Two-Wire Video Intercom Main Unit and Video Intercom Main Unit share the same installation methods. Therefore, the following installation procedures will take Video Intercom Main Unit as an example. Note Make sure the device in the package is in good condition and all the assembly parts are included.
DS-KD8003 Series Module Door Station User Manual 4.1 One-Module Installation 4.1.1 One-Module Surface Mounting Before You Start Figure 4-1 Mounting Frame Note The dimension of one module mounting frame (W × H × D) is: 117 mm × 107 mm × 32.7 mm. ●...
Page 29
DS-KD8003 Series Module Door Station User Manual Figure 4-2 Drill Screw Holes 3. Remove the stricker and insert the expansion sleeves into the screw holes. 4. Fix the mounting frame onto the wall with 4 expansion bolts.
Page 30
DS-KD8003 Series Module Door Station User Manual Figure 4-3 Fix the Mounting Frame 5. Connect the cables to the corresponding interfaces of the main unit and insert the main unit into the frame.
Page 31
DS-KD8003 Series Module Door Station User Manual Figure 4-4 Insert the Main Unit 6. Fix the cover onto the frame.
Page 32
DS-KD8003 Series Module Door Station User Manual Figure 4-5 Fix the Cover...
DS-KD8003 Series Module Door Station User Manual 4.1.2 One-Module Flush Mounting Before You Start Figure 4-6 Front and Side View of the Gang Box...
Page 34
DS-KD8003 Series Module Door Station User Manual Figure 4-7 Gang Box Note The dimension of one-module gang box is: 115 (W) × 134 (H) × 56 (D) mm. The dimension is for reference only. Steps 1. Drill an installation hole, and pull the cables out. Note The suggested dimension of installation hole is 118 (W) ×...
Page 35
DS-KD8003 Series Module Door Station User Manual Figure 4-8 Drill Installation Hole 2. Remove the plastic sheet of the cable entry. 3. Mark the gang box screw holes on the wall. 1) Route the cables through the gang box hole. 2) Insert the gang box into the installation hole.
Page 36
DS-KD8003 Series Module Door Station User Manual Note The suggested size of the hole is 6 (diameter) × 45 (depth) mm. 5. Route the cables through the gang box hole. Insert the gang box into the installation hole. Fix the gang box with 4 expansion bolts. Figure 4-10 Fix the Gang Box 6.
Page 37
DS-KD8003 Series Module Door Station User Manual Figure 4-11 Remove the Mounting Ears 7. Connect the cables to the corresponding interfaces of the main unit and insert the unit into the gang box.
Page 38
DS-KD8003 Series Module Door Station User Manual Figure 4-12 Insert the Main Unit 8. Fix the cover and the main unit with 2 socket head cap screws by using a hexagon wrench (supplied). Figure 4-13 Fix the Cover...
DS-KD8003 Series Module Door Station User Manual 4.2 Two-Module Installation 4.2.1 Two-Module Surface Mounting Before You Start Figure 4-14 Mounting Frame Note The dimension of two-module mounting frame (W × H × D) is: 219 mm × 107 mm × 32.7 mm. ●...
Page 40
DS-KD8003 Series Module Door Station User Manual Steps 1. Paste the installation Sticker 1 onto the wall. Make sure the sticker is placed horizontally via measuring with the gradienter. 2. Drill 4 holes according to the screw holes on the sticker. The suggested size of hole is 6 (diameter) ×...
Page 41
DS-KD8003 Series Module Door Station User Manual Figure 4-17 Placement of Lines 6. Connect the cables. 1) Connect the lines and module-connecting line to the corresponding interfaces of the main unit, then place the main unit into the upper grid. 2) Connect the other end of the module-connecting line to the input interface of the sub module.
Page 42
DS-KD8003 Series Module Door Station User Manual Figure 4-18 Line Connection Effect Picture 7. Insert the modules into the frame after wiring. The main unit must be placed in the top grid. Figure 4-19 Insert the Modules 8. Use the hexagon wrench in the package to fix the cover onto the frame.
Page 43
DS-KD8003 Series Module Door Station User Manual Figure 4-20 Fix the Cover...
DS-KD8003 Series Module Door Station User Manual 4.2.2 Two-Module Flush Mounting Before You Start Figure 4-21 Gang Box Note The dimension of two-module gang box is: 237 (W) × 134 (H) × 56 (D) mm. The dimension is for reference only. Steps 1.
Page 45
DS-KD8003 Series Module Door Station User Manual Note The suggested dimension of installation hole is 220 (W) × 108 (H) × 45.5 (D) mm. ● The suggested length of cables left outside is 270 mm. ● Figure 4-22 Drill the Installation Hole 2.
Page 46
DS-KD8003 Series Module Door Station User Manual Figure 4-23 Mark the Screw Holes 4. Drill 4 holes according to the marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) × 45 (depth) mm. 5.
Page 47
DS-KD8003 Series Module Door Station User Manual Figure 4-24 Fix the Gang Box 6. Fill the gap between the gang box and the wall with concrete. Remove the mounting ears with tool after concrete is dry.
Page 48
DS-KD8003 Series Module Door Station User Manual Figure 4-25 Remove the Mounting Ears 7. Connect cables and insert the modules. 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main unit, then insert the main unit into the upper grid. 2) Connect the other end of Cable 2 to the input interface of the sub module.
Page 49
DS-KD8003 Series Module Door Station User Manual Figure 4-26 Connect Cables and Insert the Modules Note Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 refers to the module-connecting line in the accessory package. 8.
DS-KD8003 Series Module Door Station User Manual 4.3 Three-Module Installation 4.3.1 Three-Module Surface Installation Before You Start Figure 4-28 Mounting Frame Note The dimension of two-module mounting frame (W × H × D) is: 320.8 mm × 107 mm × 32.7 mm. ●...
Page 51
DS-KD8003 Series Module Door Station User Manual Figure 4-29 Drill Screw Holes 3. Remove the sticker and insert the expansion sleeves into the screw holes. 4. Fix the mounting frame onto the wall with 4 expansion bolts. Figure 4-30 Fix the Mounting Frame...
Page 52
DS-KD8003 Series Module Door Station User Manual Note The mounting frame should be placed exactly as shown below for this step. The tamper plate should be at the low right of the first grid. Figure 4-31 Mounting Frame 5. Thread the module-connecting line across the thread holes of the frame. Pass the main unit connecting line across the thread hole to the top grid.
Page 53
DS-KD8003 Series Module Door Station User Manual Figure 4-32 Placement of Lines 6. Connect the cables. 1) Connect the lines and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid. 2) Connect the other end of the module-connecting line 1 to the input interface of the sub module.
Page 54
DS-KD8003 Series Module Door Station User Manual Figure 4-33 Line Connection Effect Picture 7. Insert the modules into the frame after wiring. The main unit must be placed in the top grid.
Page 55
DS-KD8003 Series Module Door Station User Manual Figure 4-34 Insert the Modules into the Frame 8. Use the hexagon wrench in the package to fix the cover onto the frame.
Page 56
DS-KD8003 Series Module Door Station User Manual Figure 4-35 Fix the Cover...
DS-KD8003 Series Module Door Station User Manual 4.3.2 Three-Module Flush Mounting Before You Start Figure 4-36 Gang Box...
Page 58
DS-KD8003 Series Module Door Station User Manual Note The dimension of one-module gang box is: 338.8(W)×134(H)×56(D) mm. ● The dimensions above are for reference only. The actual size can be slightly different from the ● theoretical dimension. Steps 1. Cave the installation hole, and pull the cable out.The suggested dimension of installation hole is 321.8(W)×108(H)×45.5(D) mm.
Page 59
DS-KD8003 Series Module Door Station User Manual Figure 4-38 Mark the Screw Holes 4. Drill 4 holes according to marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) × 45 (depth) mm. 5.
Page 60
DS-KD8003 Series Module Door Station User Manual Figure 4-40 Remove the Mounting Ears 7. Connect cables and insert the modules. 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main unit, then insert the main unit into the upper grid. 2) Connect the other end of Cable 2 to the input interface of Sub Module 1.
Page 61
DS-KD8003 Series Module Door Station User Manual Figure 4-41 Connect Cables and Insert Modules Note Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 and Cable 3 refer to the module-connecting line in the accessory package. 8.
DS-KD8003 Series Module Door Station User Manual Figure 4-42 Fix the Cover 4.4 More-Than-Three Module Installation 4.4.1 More-than-Three Module Surface Mounting Before You Start Figure 4-43 Mounting Frame...
Page 63
DS-KD8003 Series Module Door Station User Manual Note It takes two three-module mounting frames. The dimension of three-module mounting frame ● (W × H × D) is: 320.8 mm × 107 mm × 32.7 mm. The dimensions above are for reference only. The actual size can be slightly different from the ●...
Page 64
DS-KD8003 Series Module Door Station User Manual Figure 4-44 Drill Screw Holes 4. Remove the stickers and insert the expansion sleeves into the screw holes. 5. Thread the module-connecting line (400 mm) and grounding line across the thread hole of both frames.
Page 65
DS-KD8003 Series Module Door Station User Manual Figure 4-45 Place the Grounding Line and Module-Connecting Line Note There are 6 module-connecting lines in the package: 190 mm × 4 and 400 mm × 2. ● Take the 400 mm module-connecting line for this step. ●...
Page 66
DS-KD8003 Series Module Door Station User Manual Figure 4-46 Fix the Mounting Frame 7. Pass the main unit connecting line across the thread hole to the top grid of the left frame. Thread the module-connecting line (190 mm) across the thread hole of the frame. The lines should be placed as shown below.
Page 67
DS-KD8003 Series Module Door Station User Manual 8. Connect the cables. 1) Connect the cables from the wall and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid. 2) Connect the other end of the module-connecting line 1 to the input interface of the sub module.
Page 68
DS-KD8003 Series Module Door Station User Manual Figure 4-48 Line Connection Effect Picture...
Page 69
DS-KD8003 Series Module Door Station User Manual 9. Insert the modules into the frame after wiring. The main unit must be placed in the top grid on the left. Figure 4-49 Insert the Modules 10. Pull the grounding line out and fixed its two end to the screw on the cover.
Page 70
DS-KD8003 Series Module Door Station User Manual Figure 4-50 Connect the Grounding Line to the Cover 11. Use the hexagon wrench in the package to fix the cover onto the frame.
Page 71
DS-KD8003 Series Module Door Station User Manual Figure 4-51 Fix the Cover...
DS-KD8003 Series Module Door Station User Manual 4.4.2 More-Than-Three Module Flush Mounting Before You Start Figure 4-52 Gang Box...
Page 73
DS-KD8003 Series Module Door Station User Manual Note It takes two three-module gang boxes. The dimension of the gang box is: 338.8 (W) × 134 (H) × 56 (D) mm. The dimension is for reference only. Steps 1. Drill the installation hole, and pull the cable out.The suggested dimension of installation hole is 321.8 (W) ×...
Page 74
DS-KD8003 Series Module Door Station User Manual Figure 4-54 Connect Two Gang Boxes 3. Select a cable entry and remove the plastic sheet. 4. Remove the plastic sheets on the side of the gang boxes (shown as 1 and 2) below: Figure 4-55 Remove the Plastic Sheets...
Page 75
DS-KD8003 Series Module Door Station User Manual 5. Mark the gang box screw holes on the wall. 1) Route the cables through the gang box hole. 2) Insert the gang box into the installation hole. 3) Mark the gang box screw holes' position with a marker, and take out the gang box. Figure 4-56 Mark the Screw Holes 6.
Page 76
DS-KD8003 Series Module Door Station User Manual Figure 4-57 Fix the Gang Boxes 8. Fill the gap between the gang box and wall with concrete. Remove the mounting ears with tool after concrete is dry. Route the grounding line through the cable entries. Figure 4-58 Remove the Mounting Ears...
Page 77
DS-KD8003 Series Module Door Station User Manual Note The green-yellow line in the package is for grounding. 9. Connect cables and insert the modules. 1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the Main Unit, then place the Main Unit into the upper grid of the left gang box.
Page 78
DS-KD8003 Series Module Door Station User Manual Figure 4-60 Cables Connection Note Cable 2,3,5 and 6 are the module-connecting lines (190 mm) in the package. ● Cable 4 is the module-connecting line (400 mm) in the package. ● Main unit must be put in the top grid. ●...
Page 79
DS-KD8003 Series Module Door Station User Manual Figure 4-61 Connect the Grounding Line to the Cover 11. Fix the cover with 2 socket head cap screws by using a hexagon wrench (supplied).
Page 80
DS-KD8003 Series Module Door Station User Manual Figure 4-62 Fix the Cover...
DS-KD8003 Series Module Door Station User Manual Chapter 5 Activation 5.1 Activate via Web Browser You can activate the device via the web browser. Steps 1. Enter the device default IP address (192.0.0.65) in the address bar of the web browser, and press Enter.
DS-KD8003 Series Module Door Station User Manual Chapter 6 Configuration via Web Client 6.1 Login Web Browser You can log into the Web browser for device configuration. Steps 1. Enter the device IP address in the address bar of the web browser and press Enter to enter the login page.
DS-KD8003 Series Module Door Station User Manual Note If you adjust the volume when starting two-way audio, you may hear a repeated sounds. You can capture image when starting live view. Reserved function. You can zoom in the live view image. Start or stop live view.
Page 84
DS-KD8003 Series Module Door Station User Manual Figure 6-2 Add User Add Basic Information Add the person's basic information, including Employee ID, Name, Floor No. and Room No. . You also need to select the User Role. Click OK to save the settings. Set Permission Time Set Start Time and End Time and the person can only have the permission within the configured time period.
DS-KD8003 Series Module Door Station User Manual Add Fingerprint Click Add Fingerprint, and press your finger on the fingerprint module to add your fingerprint. Click Complete to save the settings. 6.4 Device Management You can manage the linked device on the page. Click Device Management to enter the settings page.
DS-KD8003 Series Module Door Station User Manual 6.5 Remote Configuration Click to set the parameters of the device. Note Run the browser, click → Internet Options → Security to disable the Protected Mode. 6.5.1 Local Parameters Settings You can configure the parameters of the live view, record files and captured pictures. The record files and captured pictures are the ones you record and capture by using the web browser.
DS-KD8003 Series Module Door Station User Manual Auto Start Live View Check Yes to enable the function. Image Format Select the image format for picture capture. Click Save to enable the settings. Record File Parameters Record File Size Select the packed size of the manually recorded and downloaded video files to 256M, 512M or 1G.
DS-KD8003 Series Module Door Station User Manual Time Zone Select the device located time zone from the drop-down list. Time Sync. You should set the alarm receiver type, NTP server's IP address, port No., and interval. Manual By default, the device time should be synchronized manually. You can set the device time manually or check Sync.
DS-KD8003 Series Module Door Station User Manual All parameters will be restored to the factory settings. You should activate the device before usage. Import and Export Parameters Click Configuration → System → Maintenance → Upgrade & Maintenance . Export Click Export to export the logs or device parameters. Note You can import the exported device parameters to another device.
DS-KD8003 Series Module Door Station User Manual Caution The password should be 8 to 16 characters. ● The password should contain at least 2 of the following types: digits, lowercase letters, ● uppercase letters and special characters. Do not contain following characters in the password: the user name, 123, admin (case- ●...
DS-KD8003 Series Module Door Station User Manual Steps 1. Click Network → Basic Settings → TCP/IP to enter the settings page. 2. Configure the network parameters. - Check DHCP, the device will get the parameters automatically. - Set the IPv4 Address, IPv4 Subnet Mask and IPv4 Default Gateway manually. 3.
Page 92
DS-KD8003 Series Module Door Station User Manual SIP Setting Steps 1. Click Network → Basic Settings → SIP to enter the settings page. Figure 6-6 SIP Settings 2. Check Enable VOIP Gateway. 3. Configure the SIP parameters. 4. Click Save to enable the settings. FTP Settings Steps 1.
Page 93
DS-KD8003 Series Module Door Station User Manual Figure 6-7 FTP Settings...
DS-KD8003 Series Module Door Station User Manual 2. Check Enable FTP. 3. Select Server Type. 4. Input the Server IP Address and Port. 5. Configure the FTP Settings, and the user name and password are required for the server login. 6.
DS-KD8003 Series Module Door Station User Manual Stream Type Select the stream type to main stream or sub stream. Video Type Select the stream type to video stream, or video & audio composite stream. The audio signal will be recorded only when the Video Type is Video & Audio. The video type is video &...
Page 96
DS-KD8003 Series Module Door Station User Manual Figure 6-9 Audio Settings 2. Configure the stream type and the audio encoding type. Audio Channel Select the audio channel to adjust the audio parameters. Stream Type Select the stream type to main stream or sub stream. Audio Encoding The device support G.711ulaw and G.711 alaw.
DS-KD8003 Series Module Door Station User Manual 6.5.13 Image Settings Display Settings Configure the image adjustment, backlight settings and other parameters in display settings. Steps 1. Click Image → Display Settings to enter the display settings page. Figure 6-10 Display Settings 2.
Page 98
DS-KD8003 Series Module Door Station User Manual Sharpness Sharpness describes the edge contrast of the image, which ranges from 1 to 100. 5. Set the Day/Night Switch. Figure 6-11 Day/Night Switch - Set Daytime or Night. - Set the mode as Auto and edit the sensitivity according to your needs. - Set the mode as Scheduled-Switch.
DS-KD8003 Series Module Door Station User Manual OSD Settings You can customize the camera name, time/date format on the live view. Steps 1. Click Image → OSD to enter the settings page. Figure 6-13 OSD 2. Check to enable Display Name, Display Date or Display Week at your actual needs. 3.
DS-KD8003 Series Module Door Station User Manual Note You can select Cropping Resolution as 704*576, 1280*720, or 1920*1080. ● You can zoom in or zoom out the image by selecting Cropping Resolution after clicking Save. ● 6.5.14 Event Settings Motion Detection Motion detection detects the moving objects in the configured security area, and a series of actions can be taken when the alarm is triggered.
Page 101
DS-KD8003 Series Module Door Station User Manual Figure 6-14 Motion Detection 2. Click to Enable Motion Detection. 3. Click Draw Area. Click and drag to draw a motion detection area. Clear Area Click Clear All to clear all of the areas. Adjust Sensitivity Move the slider to set the sensitivity of the detection.
Page 102
DS-KD8003 Series Module Door Station User Manual Delete Schedule Click Delete to delete the current arming schedule. 6. Click Linkage Method to enable the linkages. Notify Security Center Send an exception or alarm signal to the remote management software when an event occurs.
Page 103
DS-KD8003 Series Module Door Station User Manual Figure 6-15 Event Linkage...
DS-KD8003 Series Module Door Station User Manual 2. Select the Major Type as Device Event or Door Event. 3. Select the type of the Normal Linkage for the event. 4. Click Save to enable the settings. 6.5.15 Schedule Settings You can create call schedule, or else the device will call indoor station all day by default. Steps 1.
DS-KD8003 Series Module Door Station User Manual Figure 6-17 Holiday Schedule 2) Click Add. 3) Set Start Time and End Time. 4) Select Call Type. 5) Drag mouse to set the schedule according to the actual needs. 6) Click OK. 7) You can edit or delete the schedule according to the actual needs.
DS-KD8003 Series Module Door Station User Manual After enable the DESFire card content reading function, the device can read the DESFire card 6.5.17 Intercom Settings Device No. Configuration Set the No. of the device, and linked devices can build a communication. Steps 1.
DS-KD8003 Series Module Door Station User Manual Linked Network Settings Steps 1. Click Intercom → Session Settings to enter the settings page. Figure 6-19 Session Settings 2. Set Registration Password. 3. Set Main Station IP and Video Intercom Server IP. 4.
Page 108
DS-KD8003 Series Module Door Station User Manual Set password and remarks and click to enable electric lock. Click Save to save the settings. Call Settings Go to Intercom → Call Settings to enter the page. Configure Max. Call Duration, Max. Message Duration and Max. Ring Duration, and click Save. Note Max.
Page 109
DS-KD8003 Series Module Door Station User Manual Set I/O Parameters You can set I/O Parameters on PC Web. Steps 1. Click Configuration → Video Intercom → I/O Settings . 2. Select Input 2 as Disable or Door Status. Select Input 3 and Input 4 as Disable or Exit Button. Note The Input 1 is Door Status by default.
DS-KD8003 Series Module Door Station User Manual Note The module address is used to differentiate the sub modules. ● K12 module, KK module and alarm in module belong to nametag modules. ● The room No. for the main unit's call button is 1 by default; and the room No. for other call ●...
DS-KD8003 Series Module Door Station User Manual Figure 6-22 Door Parameters 2. Select Door No., and edit the Name. 3. Set Open Duration. When the time to open over the open duration you set, the door will be locked again. 4.
Page 112
DS-KD8003 Series Module Door Station User Manual Figure 6-23 Elevator Control 2. Check to enable elevator control function. 3. Select an Elevator No., and select an elevator controller. 4. Select Interface Type. 5. Enter Negative Floor Capacity, and select Alarm Receiver Type. 6.
Page 113
DS-KD8003 Series Module Door Station User Manual Note Up to 4 elevator controllers can be connected to one door station. ● Up to 10 negative floors can be added. ● Make sure the interface types of elevator controllers, which are connected to the same door ●...
Need help?
Do you have a question about the DS-KD8003Y-IME2/S and is the answer not in the manual?
Questions and answers