Operation and installation manual
KNX IO 411 (4Ii)
(Art. # 5231)
Binary input with 4 channels
KNX IO 411 (4Ii)
Application area
The KNX IO 411 (4Ii) is compact binary input with 4 channels to
control lights, shutter etc. with conventional switches or contacts.
Inputs are designed for dry contacts.
Two push buttons and three LEDs allow a local operation and a
visualization of the device state.
In addition to the input channels the device includes 16 inde-
pendent functions for logic or timer control.
1. Installation and Connection
The KNX IO 411 (4Ii) is designed for installation on a DIN rail (35
mm) with a width of 1 unit (18 mm). An installation-friendly de-
sign with pluggable screw terminals helps to reduce the cost of
commissioning. It features the following controls and displays:
KNX bus connector
Programming LED
Button f. programming mode
1/1 LED (multicolor )
WEINZIERL
Ch/M LED (multicolor )
1/1
Ch/M
2/2 LED (multicolor )
2/2
Button A1
A
1
P/Esc
Button B2
B
2
Pluggable screw terminals
411
This device is powered by the KNX bus. An external power
supply is not necessary
The device is not working without bus power.
©2019 WEINZIERL ENGINEERING GmbH
A.
KNX Programming mode
The KNX programming mode is activated/deactivated either by
pressing the flushed KNX programming button
neously pressing the buttons
When the programming mode is active, the programming LED
and LED Ch/M
light red.
2. Manual operation and status display
The LED Ch/M
lights up or flashes if the device is successful-
ly powered by the KNX bus
By pressing button A1
long, the manual operation mode will
be entered for channel pair A (Ch A In1/In2). This is indicated by
cyclic single flashing of LED Ch/M
By pressing button B2
long, the manual operation mode will
be entered for channel pair B (Ch B In1/In2). This is indicated by
cyclic double flashing of LED Ch/M
If manual operation of a channel pair is activated, the bus tele-
grams of In1 and In2 can be triggered by button A1
, if input channel is configured by ETS.
LED 1/1
and LED 2/2
lected channel pair while manual operation. They light green
when the button A1
or B2
Summary of the states of LED Ch/M
LED Status
Meaning
LED lights green
Device is working in standard operation mode.
LED lights red
Programming mode is active.
LED flashes 1x
Programming mode is not active.
orange
Manual operation is active:
Switching first channel pair (Ch A In1/In2)
LED flashes 2x
Programming mode is not active.
orange
Manual operation is active:
Switching first channel pair ( Ch B In1/In2)
Programming mode is not active.
Manual operation is not active.
LED blinks red
The device is not properly loaded
e.g. after an interrupted download .
LED blinks green
The device is currently loaded by the ETS.
3. Reset to factory device settings
It is possible to reset the device to its factory settings:
Disconnect the KNX Bus connector
Press the KNX programming button
pressed down
Reconnect the KNX Bus connector
Keep the KNX programming button
least another 6 seconds
A short flashing of all LEDs (
successful reset of the device to factory default settings.
or by simulta-
and
.
in orange.
in orange.
and B2
are used to indicate state of se-
is pressed.
:
from device
and keep it
of device
pressed for at
❷❹❺❻
) visualizes the
Page 1/11