Introduction to Solis Inverter
Product Description
Details the Solis EO series inverter designed for off-grid systems, its flexibility, and model list.
System Connection Diagram
Illustrates the system connection diagram, showing PV, Battery, Generator, Grid, and Load connections.
Inverter Packaging Contents
Lists the items included in the inverter packaging, ensuring all necessary components are present.
Safety and Warning Guidelines
Safety Symbol Definitions
Defines danger, warning, caution, and note symbols used for safety instructions in the manual.
General Safety Instructions
Provides crucial safety guidelines for electrical installations, connections, and handling the inverter.
Installation Procedures
Usage and Disposal Notices
Advises on proper inverter usage, disposal, and environmental considerations.
Location Selection Criteria
Outlines criteria for selecting an optimal installation location, considering sunlight, temperature, and clearance.
Inverter Mounting Instructions
Details the vertical mounting procedure for the inverter, including height selection and screw usage.
Installation Preparation Steps
Describes the initial step of removing the bottom cover before proceeding with wiring connections.
PV Input Terminal Assembly
Guides on connecting PV modules, including voltage limits, polarity, breaker installation, and wire preparation.
AC Connector Assembly
Instructs on connecting AC input/output wires, specifying cable size, torque, and connection sequence.
Grounding Procedure
Explains the grounding method to protect the inverter, detailing terminal connection and screw tightening.
Battery Components and Connection
Covers battery types, components, and connection procedures, emphasizing safety and polarity.
Battery Communication Setup
Describes using RS485 for BMS/NTC communication with Lithium and Lead-acid batteries.
External Communication Setup
Explains RS-485 communication for transmitting data to PCs or monitoring equipment.
Generator Connection Options
Details connecting an AC generator to the inverter via AC Input or GEN port for backup power.
AC Coupling Connection Method
Explains how the inverter controls PV grid-tied inverters using frequency adjustment for AC coupling.
Parallel Connection Guide
Covers parallel connection of multiple inverters to expand system capacity, including limitations.
External Communication Stick
Mentions connecting a monitoring port for transmitting data to a monitoring website.
LED Indicator Functions
Describes the function and color of the three LED indicators on the inverter for status monitoring.
Commissioning and Operation
Commissioning Preparation
Lists essential checks before commissioning, including accessibility, ventilation, and connections.
Commissioning Procedure
Outlines the steps for initial startup, including switching power, configuring parameters, and verifying system operation.
Startup Guide and Wizard
Guides users through the initial setup process via the Startup Wizard, covering language, time, battery, and generator settings.
Main Menu Overview
Describes the four main submenus available in the inverter's operation interface: Information, Settings, Advanced Info, Advanced Settings.
System Information Display
Details how to view operating data: General Info, System Info, Energy Records, and BMS Information.
Settings Configuration
Covers various settings like time/date, address, mute, and mode configurations for optimal inverter operation.
Advanced Information Access
Provides access to detailed system information like alarm messages, warnings, running status, communication, and yield profiles.
Warning Messages
Explains how to view stored warning messages on the inverter's screen.
Running Status Details
Allows maintenance personnel to view real-time running information such as voltages, currents, and temperatures.
Communication Data
Shows communication data between HMI and DSP, intended for Solis engineers.
Yield Profile Data
Displays energy yield data categorized into Battery, Grid, and Backup energy records.
Advanced Settings Menu
Accesses advanced configurations for backup, battery, parallel, generator, AC coupling, and passwords.
Battery Settings Configuration
Allows selection of battery type and configuration of advanced battery parameters for optimal performance.
Special Settings Access
Provides access to specialized settings for maintenance personnel, including power switch and protection configurations.
Battery Line Impedance Setting
Sets battery line impedance to compensate for resistance loss, with a default value of 10mΩ.
MPPT Scan Configuration
Enables periodic MPPT scanning to track the system's global maximum power point.
PV Insulation Limit Setting
Sets the PV insulation protection limit for safety monitoring.
Daily PV-ISO Detection
Allows enabling or disabling the daily PV-ISO detection function.
Clear Energy Data
Resets the historical yield data of the inverter.
Restore Default Settings
Resets all inverter settings back to their default factory values.
AFCI Protection Settings
Enables or disables the Arc Fault Detection function and clears AFCI faults.
Parallel Settings
Configures settings for single unit or parallel operation, including address ID and master/slave roles.
Generator Settings
Manages generator connection, power settings, start-stop conditions, and force start/stop functions.
AC Coupling Settings
Configures AC coupling settings to control PV inverter generation using frequency adjustment.
Password Settings
Allows changing the password for accessing advanced settings and functions.