Technical Service; Specifications; Service Hints - Desa Vanguard GVR35PA Owner's Operation And Installation Manual

Desa owner's operation and installation manual vented propane gas heaters gvr65bpa, gvr65pa, gvr50bpa, gvr50pa, gvr35pa
Table of Contents

Advertisement

TECHNICAL
SERVICE

SPECIFICATIONS

SERVICE
HINTS
100791
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International's Technical Service Department at 1-800-323-
5190.
BTU
Type Gas
Ignition
Pressure Regulator Setting 10.5" W.C.
Inlet Gas Pressure
Maximum
Minimum
Dimensions, Inches
Heater (H x W x D) 25 x 27
Shipping Weight (pounds) 97
Flue Vent Size
Orifice Size
** When equipped with blower
These heaters are certified for elevations of 0-4500 feet above sea level. For
Note:
elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burner will produce yellow flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.
35,000 BTU/Hr 50,000 BTU/Hr
Model
Model
35,000
50,000
Propane Only
Propane Only
Piezo
Piezo
10.5" W.C.
14" W.C.
14" W.C.
11" W.C.
11" W.C.
1
/
x 16
27 x 32
4
133**/120
4" dia.
4" dia.
52 drill, ø .0635
46 drill, ø .081
65,000 BTU/Hr
Model
65,000
Propane Only
Piezo
10.5" W.C.
14" W.C.
11" W.C.
1
3
/
x 16
31 x 37
/
x 16
2
4
158**/145
5" dia.
2.4 mm, ø .0945
35