Pressure protection valves

Advertisement

Quick Links

®
Bendix
PR-2
, PR-3
DESCRIPTION
The pressure protection valve is a normally closed, pressure
control valve which can be referred to as a non-exhausting
sequence valve. These valves are used in many different
applications. An example would be in an air brake system
to protect one reservoir, or reservoir system from another,
by closing automatically at a preset pressure should a
reservoir system failure occur. The valves can also be used
PR-3
OR PR-4
PRESSURE PROTECTION VALVES
SPRING
SUPPLY
PORT
PR-4
PRESSURE PROTECTION VALVE
& PR-4
Pressure Protection Valves
CAP
PISTON
INLET
VALVE
DELIVERY
PORT
to delay filling of auxiliary reservoirs to insure a quick build-up
of brake system pressure.
The PR-2
and PR-4
pressure protection valves have one
1/4" N.P.T.F. supply port and one 1/4" N.P.T.F. delivery port
which are identified. Both valves are provided with two 9/32"
mounting holes through the body. The closing pressure of
the PR-2
valve is externally adjustable while the PR-4
valve has a fixed setting.
CAP
INLET
VALVE
SUPPLY
PORT
PR-3
PRESSURE PROTECTION VALVE
PRESSURE
REGULATING
SPRING
EXHAUST
VENT
PISTON
O-RING
PISTON
SUPPLY
PORT
SPRING
RETAINER
INLET
VALVE
PR-2
PRESSURE PROTECTION VALVE
SPRING
PISTON
CHECK
VALVE
DELIVERY
PORT
PISTON PLUG
PISTON PLUG
O-RING
VALVE STEM
INLET
VALVE SPRING
DELIVERY
PORT
1

Advertisement

loading

Summary of Contents for BENDIX PRESSURE PROTECTION VALVES

  • Page 1 ™ ™ The PR-2 and PR-4 pressure protection valves have one control valve which can be referred to as a non-exhausting 1/4" N.P.T.F. supply port and one 1/4" N.P.T.F. delivery port sequence valve. These valves are used in many different which are identified.
  • Page 2 No two vehicles operate under identical conditions, as a with genuine Bendix parts available at Bendix outlets. result, maintenance intervals may vary. Experience is a valuable guide in determining the best maintenance interval REMOVING AND INSTALLING for air brake system components.
  • Page 3 PERSONAL INJURY OR DEATH: system pressure has been depleted. ® When working on or around a vehicle, the following 8. Use only genuine Bendix replacement parts, general precautions should be observed at all times. components and kits. Replacement hardware, tubing, hose, fittings, etc. must be of equivalent 1.
  • Page 4 BW1440 © 2006 Bendix Commercial Vehicle Systems LLC. All rights reserved. 7/2006 Printed in U.S.A.

This manual is also suitable for:

Pr-2Pr-3Pr-4