Parker Balston Ultra Pure UHPN2-1100 Installation, Operation And Maintenance Manual

Parker Balston Ultra Pure UHPN2-1100 Installation, Operation And Maintenance Manual

Nitrogen generators

Advertisement

Bulletin TI-N2-1100K
Quick Start Summary
Parker Balston
Nitrogen Generators
Models HPN2-1100 and UHPN2-1100
Installation, Operation, and Maintenance Manual
1-800-343-4048
Installation, Operation and Maintenance Manual
Parker Balston Model HPN2-1100, UHPN2-1100
Ultra Pure
®
1
www.balstonlabgasgenerators.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra Pure UHPN2-1100 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Quick Start Summary
Installation Requirements
Details about ambient temperature, electrical, and compressed air requirements for installation.
Startup and Operation
Steps for starting the nitrogen generator and adjusting outlet flow parameters.
Outlet Flow Specifications
Table showing minimum inlet pressure, maximum outlet flow, and maximum outlet pressure.
Diagnostics and Indicators
Explanation of indicator lights and pressure gauges for system monitoring.
General Handling and Placement
General handling and installation guidelines for the free-standing unit.
Location and Utilities
Guidelines for generator location and requirements for compressed air, power, and piping.
Recommended Accessories
Details on optional accessories including drain line, regulators, flow controllers, and prefilters.
Generator Startup Procedure
Step-by-step guide for initiating the nitrogen generator's warm-up period.
Handling Interruptions
How the generator responds to interruptions in air pressure or electrical power.
Flow Rate Control
Guidance on controlling nitrogen flow using metering valves or flow controllers.
Shutdown Protocol
Correct steps for shutting down the generator to prevent PSA tower poisoning.
Maintenance Overview
Summary of primary maintenance tasks like filter and catalyst module replacement.
Troubleshooting and Support
Guidance on diagnosing common problems and warranty/service contact information.
Technical Information
General Description
Overview of Parker Balston HPN2-1100 and UHPN2-1100 UHP Nitrogen Generators.
Engineered System Components
Details on the four primary stages of the nitrogen generation system.
Prefiltration System
Description of the high-efficiency coalescing filter for removing contaminants.
Hydrocarbon Removal (UHPN2-1100)
Details on the catalyst module for oxidizing hydrocarbons in the UHPN2-1100 model.
Oxygen Removal Process
Explanation of the PSA technology used for removing oxygen, water, and CO₂.
Final Filtration Stage
Description of the Balston Grade GS membrane filter for particulate removal.
System Specifications
Detailed technical specifications including purity, concentration limits, and electrical requirements.
Optional Accessories Catalog
Part numbers and descriptions for optional accessories like oxygen traps and filters.

Table of Contents