Protocol Trace Option; Tracing Cas/Robbed Bit Protocols - OPTICOM OPERA E1-T1 User Manual

Interface option
Table of Contents

Advertisement

C H A P T E R
7 :
O P T I O N S
STOP_SEND_MF
SEND_PROG_TON
(Operation,
Tone or NONE)
CHANGE_COLLECT_TYPE
(Collect Type)
Table 7.4: List of available User-functions and their parameters (in brackets).
Next State
This column contains the next state the table moves to, after executing the
function for the particular action/event line. When the user selects to stay in
the same state, insert NO_STATE or use the current state.
Note the difference between NO_STATE and the current state name in this
field. If the user selects to stay in the same state he is currently in, the
unconditional actions (FUNCTION0) at the beginning of the state are
performed. In contrast, NO_STATE skips these function and just waits for
another action to come.
The reserved word "DO" must be written in the next state field if the
unconditional actions (FUNCTION0) at the beginning of the state are used.
[AUDI01]
7.3

Protocol Trace Option

7.3.1 Tracing CAS/Robbed Bit Protocols

To fully understand a CAS/Robbed Bit protocol trace, you need to be
familiar of how to edit a CAS protocol table, see Section 7.2. Tracing of CAS
protocols is supported by choosing the protocol trace level in the Windows
NT registry. If you want to check or change the protocol trace level, open
the
registry
key
opticonf\Board#<x>\Trunk#<y>
board and <y> the trunk ID that you want to set the trace level for. If you
are not familiar with the usage of the operating system registry, please ask a
specialist for support.
Go to the specified registry key and you will find an entry
"
ProtocolTraceLevel
trace) 1 (Full Trace) or 2 (Layer3 ISDN Trace). For the trace utility for
F O R
A D V A N C E D
Use index 0 to send last sent digit.
Use index SEND_FIRST_DIGIT (see CASSetup.h)to start sending
the digits vector from the beginning.
MF Send Time - The send time parameter specifies the maximum
transmission time of the MF.
Stop sending the current MF.
Two operations are available:
1. Send the call progress tone specified in the Parameter #2 rubric (The
second parameter can be taken from CASsetup.h).
2. Stop sending the last parameter.
Used only in MFC-R2 protocol by the incoming user to indicate his waiting
for the reception of MF digit of the requested type. The type can be one of
the following:
ADDRESS - User is waiting for the reception of address digits.
ANI - User is waiting for the reception of ANI digits.
SOURCE_CATEGORY - User is waiting for the reception of the source
category.
TRANSFER_CAPABILITY - User is waiting for the reception of the source
transfer capability (line category).
"