6.2

Example 1: Stand Alone Loop Measurement

First of all, in order to perform a loop call, you will have to take care that the
telephone line is looped back on the far end, so you will get your signal to
the terminating line. After having connected both trunks of the E1/T1
interface board to the SUT, start the board parameter configurator by
choosing the menu Start|Programs|Opera|OptiConf. In the dialog of
OptiConf™, we select the protocol type "E1_MFCR2" as shown in Figure
6.1. The protocol version "Mfcr2_ITU" is chosen with a subversion using 5
digits without ANI function.
We will run a measurement from B-channel 0 with OptiCall™. For this B-
channel, the parameter settings as shown in Figure 6.2 are selected within
the B-channel configuration dialog. Confirm the B-channel configuration
with the OK button.
All the other parameter values in the main dialog of OptiConf™ are assumed
to be fine in our example. We leave them as they are and start the
initialization process by clicking on the Apply button.
E X A M P L E S
Value
National Number
ISDN Numbering Plan
National Number
Presentation Allowed
User Provided
-
-
Voice Service
-
Exclusive Selection
29