The Parameter Field "Termination Side; The Parameter Field "Set B-Channel Parameters; Setting Up B-Channel Configuration Parameters - OPTICOM OPERA E1-T1 User Manual

Interface option
Table of Contents

Advertisement

C H A P T E R
3 :
S E T U P

3.2.11 The Parameter Field "Termination Side"

Some protocols are not symmetrical, that is, the user and the network side of
the protocol are different. In the Termination Side control field you may
change whether your OPERA host computer shall be configured as the user
side or the network side of a protocol.

3.2.12 The Parameter Field "Set B-Channel Parameters"

For some protocol types, like ISDN or MFC-R2, the parameters for the B-
channels need to be set.. In this field you may select from the drop-down list
the B-channel you want to configure. After clicking on the "Configure"
button, the dialog for the B-channel configuration will come up as shown in
Figure 3.2.
Please note, that only those channels are shown in the list that may carry
voice information. That is, for instance, the D-channel of an ISDN
configured trunk will not be found in the B-channel list. The numbering of
the B-channels starts with zero.
Note:
Currently only identical configuration setups of Trunk 1 and
Trunk 2 are possible. This is about to change in future
versions of the E1/T1 option.
3.3

Setting up B-Channel Configuration Parameters

Sections 3.1.9 to 3.1.16 describe a number of parameters that are to be set
for each single B-channel of a trunk. Most of these channel c onfiguration
parameters are applicable for ISDN. Only some might be applicable for
MFC-R2 protocols, too, which are Source Phone Number, Source Phone
Subnumber, Source Number Type and Transfer Capability.
For modifying B-channel parameter settings, choose the B-channel that your
changes shall apply to in the main dialog of OptiConf™. When pressing the
"Configure" button the dialog shown in Figure 3.2 will come up. Here, you
will see the current settings of the selected B-channel. The parameter values
for each B-channels are set separately, and modifying them for one specific
B-channel will not affect the settings of another B-channel.
You may also configure all available B-Channels in one step by selecting the
entry "All Channels" from the drop-down list in the "Set B-Channel
Parameters" field of the main dialog.
In the following, an overview of the B-channel parameters is given.
O F
T H E
E 1 / T 1
B O A R D
12
P A R A M E T E R S