PRODUCT OVERVIEW DIMENSIONS INSTALLATIONS ACTUATORS COMMUNICATIONS MODULES ACCESSORIES REPLACEMENTS MAINTENANCE AND OPERATION FIRE DAMPER - FD PRODUCT OVERVIEW TESTS AND FIRE RESISTANCE CERTIFICATES CLASSIFICATION All our dampers are submitted to a number of tests by official FD fire resistance is tested according to EN 1366-2 “Fire Please consult latest Declaration of Performance on our test institutes.
CLASS C EN1751 SERIAL NUMBER: 28502800400001 PRODUCTION DATE: 01.01.2020 PRODUCT OVERVIEW TYPE: FDC40-d500-M24-S DIMENSIONS TECHNICAL DATA DIMENSION: d500 LOCATION: INSTALLATIONS ACT. MECHANISM: IP PROTECTION: IP54 Fire damper casing is manufactured from galvanized NOMINAL VOLTAGE: AC/DC 24V FRE SPACE (dm2): ACTUATORS steel sheet, but on demand can be produced out of: SIGNALISATION: THERMAL FUSE: 72˚C...
Page 5
MODELS PRODUCT OVERVIEW Casings DIMENSIONS FD25 Fire damper with 25 mm damper blade and fire INSTALLATIONS classification up to EI120S. Sizes range from 100x200 till 800x600. ACTUATORS FD40 Fire damper with 40 mm damper blade and fire COMMUNICATIONS MODULES classification up to EI120S. Sizes range from 800x600 till 1500x800.
Page 6
PRODUCT OVERVIEW DIMENSIONS FD25/FD40 - R INSTALLATIONS (manual mechanism) ACTUATORS • Automatic closure when the temperature COMMUNICATIONS MODULES in the duct exceeds 72 °C • Manual rearming with handle ACCESSORIES • Manual unlocking possible for periodical test of fire damper REPLACEMENTS •...
Page 7
PRODUCT OVERVIEW DIMENSIONS FD25/FD40 - EMS INSTALLATIONS (solenoid actuator) ACTUATORS • Spring return actuator with integrated limit COMMUNICATIONS MODULES switches and thermal fuse release mechanism (72 °C) ACCESSORIES • Manual re arming with handle • Possible closing with solenoid REPLACEMENTS •...
Page 8
PRODUCT OVERVIEW DIMENSIONS FD25/FD40 - M INSTALLATIONS (electric actuator) ACTUATORS • Thermoelectric release device (72 °C) with COMMUNICATIONS MODULES electric actuator and return spring ACCESSORIES • Integrated end switches • Fully automatic operation REPLACEMENTS • Optional 95 °C thermoelectric release device for warm air installations MAINTENANCE AND OPERATION DIMENSIONS...
Page 9
PRODUCT OVERVIEW DIMENSIONS FD25/FD40 - EX INSTALLATIONS (electric actuator) ACTUATORS COMMUNICATIONS MODULES • Thermoelectric release device (72 °C) with electric actuator and return spring ACCESSORIES • Integrated end switches • Fully automatic operation REPLACEMENTS • The EX version of the damper comes with: 1) Safety temperature trigger Schischek MAINTENANCE AND OPERATION ExPro-TT...
Page 10
PRODUCT OVERVIEW DIMENSIONS FD25 - APP INSTALLATIONS Applique installation ACTUATORS frame COMMUNICATIONS MODULES ACCESSORIES • Applique kit is an installation subframe for quick and easy installation in rigid and flexible walls REPLACEMENTS • Made out of calcium silicate boards • Quick wall mounting with screws MAINTENANCE AND OPERATION •...
Page 11
PRODUCT OVERVIEW DIMENSIONS FD25 INSTALLATIONS MF1 installation ACTUATORS frame COMMUNICATIONS MODULES ACCESSORIES • MF1 is an installation frame for quick and easy installation in rigid and flexible walls REPLACEMENTS • Made out of calcium silicate boards • MAINTENANCE AND OPERATION Quick wall mounting with screws •...
Page 12
PRODUCT OVERVIEW DIMENSIONS FD25/FD40 INSTALLATIONS MF2 installation ACTUATORS frame COMMUNICATIONS MODULES ACCESSORIES • MF2 is an installation frame for quick and easy installation in rigid and flexible walls REPLACEMENTS • Made out of calcium silicate boards • MAINTENANCE AND OPERATION Quick wall mounting with screws •...
Page 15
Pressure drop tables Pressure drop values are described with the “Zeta” values for each size. The exact pressure drop in [Pa] is calculated using the following formula: Δp [Pa]= ζ * v² * 0,6 where ζ is Zeta value from the tables below, v is airflow PRODUCT OVERVIEW velocity in [m/s] DIMENSIONS...
PRODUCT OVERVIEW DIMENSIONS INSTALLATION INSTALLATIONS The FD25/FD40 fire damper is always tested in ACTUATORS standardized support frames (both in a concrete wall and in a flexible wall) in accordance with EN 1366-2: COMMUNICATIONS MODULES 2015 table 3/4/5. The results obtained are valid for all similar support frames which have a thickness and/or ACCESSORIES density and/or fire resistance similar or greater than...
Page 17
Supporting Wall Supporting construction Tested Range Type of installation Classification Details construction thickness details under pressure INSTALLATION Gypsum plaster/Mortar 500Pa EI 120 (ve i↔o)S Aerated concrete Check for more information about certificate ( ≥ 550 kg/m³) Rigid wall Mineral wool and cover boards ≥...
Page 18
INSTALLATION Check for more information about certificate Aerated concrete installations in the declaration of performance: REMOTE FROM WALL ( ≥ 550 kg/m³) Rigid wall ≥ 110 mm EI 60 (ve i↔o)S 300Pa (Promat) Reinforced concrete (≥ 2200kg/m³) https://solid-air.nl/downloads/ Aerated concrete Rigid wall ( ≥...
Page 19
PRODUCT OVERVIEW DIMENSIONS Rigid wall installation INSTALLATIONS (mortar sealing) ACTUATORS COMMUNICATIONS MODULES The wall is composed of concrete blocks ACCESSORIES (minimum density of 550 kg/m³) or reinforced concrete (minimum density of 2200 kg/m³) REPLACEMENTS and with a minimum thickness of 100 mm. Installation material: mortar (C).
Page 20
PRODUCT OVERVIEW DIMENSIONS Rigid wall INSTALLATIONS installation ACTUATORS (mineral wool COMMUNICATIONS MODULES sealing) ACCESSORIES The wall is composed of concrete blocks REPLACEMENTS (minimum density of 550 kg/m³) or reinforced concrete (minimum density of 2200 kg/m³) MAINTENANCE AND OPERATION and with a minimum thickness of 100 mm. Installation material: mineral wool (C) (minimum density of 100 kg/m³) covered with plasterboard cover boards (D).
Page 21
PRODUCT OVERVIEW DIMENSIONS Rigid wall INSTALLATIONS installation ACTUATORS (Fire Batt/ COMMUNICATIONS MODULES Weichschott) ACCESSORIES The wall is composed of concrete blocks REPLACEMENTS (minimum density of 550 kg/m³) or reinforced concrete (minimum density of 2200 kg/m³) MAINTENANCE AND OPERATION and with a minimum thickness of 100 mm. Installation material: mineral wool (C) (minimum density of 140 kg/m³), fire protection coating (D).
Page 22
PRODUCT OVERVIEW DIMENSIONS Gypsum blocks wall INSTALLATIONS installation ACTUATORS (mortar sealing) COMMUNICATIONS MODULES The wall is composed of gypsum blocks ACCESSORIES (minimum density of 995 kg/m³) and with minimum thickness of 70 mm. REPLACEMENTS Installation material: gypsum plaster or mortar (C), covered with plasterboard cover boards (D).
Page 23
> 440 Flexible wall installation PRODUCT OVERVIEW (mortar sealing) DIMENSIONS INSTALLATIONS The wall is composed of 2x2 plasterboard boards, 12,5 mm thick, installed on a steel frame construction. ACTUATORS Installation material: gypsum plaster or mortar (C) covered with type F(EI 120) or type A(EI 60) cover COMMUNICATIONS MODULES boards (D).
Page 24
> 440 Flexible wall installation PRODUCT OVERVIEW (mineral wool DIMENSIONS sealing) INSTALLATIONS The wall is composed of 2x2 plasterboard boards, ACTUATORS 12,5 mm thick, installed on a steel frame construction. Installation material: mineral wool (C) (minimum density COMMUNICATIONS MODULES of 100 kg/m³) covered with type F(EI 120) or type A(EI 60) cover boards (D).
Page 25
Flexible wall installation PRODUCT OVERVIEW (Fire Batt/ DIMENSIONS Weichschott) INSTALLATIONS ACTUATORS The wall is composed of 2x2 plasterboard boards, 12,5 mm thick, installed on a steel frame construction. COMMUNICATIONS MODULES Installation material: mineral wool (C) (minimum density of 140 kg/m³) and fire protection coating (D). The ACCESSORIES minimum thickness of the wall is 100 mm.
Page 26
PRODUCT OVERVIEW DIMENSIONS Rigid floor/ceiling INSTALLATIONS installation ACTUATORS (mortar sealing) COMMUNICATIONS MODULES The floor/ceiling is composed of concrete blocks ACCESSORIES (minimum density of 550 kg/m³) or reinforced concrete (minimum density of 2200 kg/m³) REPLACEMENTS and with a minimum thickness of 100 mm. Installation material: gypsum plaster or MAINTENANCE AND OPERATION mortar (C).
Page 27
PRODUCT OVERVIEW DIMENSIONS Rigid floor/ceiling INSTALLATIONS installation ACTUATORS (Fire Batt/ COMMUNICATIONS MODULES Weichschott) ACCESSORIES The floor/ceiling is composed of concrete blocks REPLACEMENTS (minimum density of 550 kg/m³) or reinforced concrete (minimum density of 2200 kg/m³) MAINTENANCE AND OPERATION and with a minimum thickness of 100 mm. Installation material: mineral wool (C) (minimum density of 140 kg/m³), fire protection coating (D).
Page 28
PRODUCT OVERVIEW DIMENSIONS Suspension for INSTALLATIONS mortarless floor ACTUATORS installation COMMUNICATIONS MODULES Suspension systems are required for the Fire Batt/ ACCESSORIES Weichschott installation of the fire damper with mineral wool in floor slabs. Fire dampers can be REPLACEMENTS suspended from solid floor slabs using adequately sized threaded rods.
Page 29
PRODUCT OVERVIEW DIMENSIONS Suspension for INSTALLATIONS mortarless ceiling ACTUATORS installation COMMUNICATIONS MODULES Suspension systems are required for the Fire Batt/ ACCESSORIES Weichschott installation of the fire damper with mineral wool in floor ceiling slabs. Fire dampers can be REPLACEMENTS suspended from solid ceiling slabs using adequately sized threaded rods.
Page 30
PRODUCT OVERVIEW Suspension DIMENSIONS for mortarless INSTALLATIONS installation close ACTUATORS to ceiling COMMUNICATIONS MODULES ACCESSORIES Suspension systems are required for the dry mortarless installation of the fire damper with mineral REPLACEMENTS wool in solid walls and flexible walls. Fire dampers can be suspended from solid ceiling slabs using MAINTENANCE AND OPERATION adequately sized threaded rods.
Page 31
PRODUCT OVERVIEW DIMENSIONS Rigid wall INSTALLATIONS installation ACTUATORS Applique installation COMMUNICATIONS MODULES frame ACCESSORIES REPLACEMENTS The wall is composed of concrete blocks (minimum density of 550 kg/m³) or MAINTENANCE AND OPERATION reinforced concrete (minimum density of 2200 kg/m³) and with a minimum thickness of 100 mm. Possible damper orientations INSTALLATION FIRE DAMPER - FD...
Page 32
PRODUCT OVERVIEW DIMENSIONS Gypsum blocks wall INSTALLATIONS installation ACTUATORS Applique installation COMMUNICATIONS MODULES frame ACCESSORIES REPLACEMENTS The wall is composed of gypsum blocks (minimum density of 995 kg/m³), and with MAINTENANCE AND OPERATION minimum thickness of 70 mm. Possible damper orientations INSTALLATION FIRE DAMPER - FD 1.
Page 33
PRODUCT OVERVIEW DIMENSIONS Flexible wall INSTALLATIONS installation ACTUATORS Applique installation COMMUNICATIONS MODULES frame ACCESSORIES The wall is composed of 2x2 plasterboard boards, REPLACEMENTS 12,5 mm thick, installed on a steel frame construction. To fulfill the classification it is NOT mandatory to use MAINTENANCE AND OPERATION the mineral wool inside the wall (mineral wool with density up to 100 kg/m³...
Page 34
PRODUCT OVERVIEW DIMENSIONS Rigid wall INSTALLATIONS installation ACTUATORS MF1/MF2 COMMUNICATIONS MODULES installation frame ACCESSORIES REPLACEMENTS The wall is composed of concrete blocks (minimum density of 550 kg/m³) or MAINTENANCE AND OPERATION reinforced concrete (minimum density of 2200 kg/m³) and with a minimum thickness of 100 mm. Possible damper orientations INSTALLATION FIRE DAMPER - FD...
Page 35
PRODUCT OVERVIEW DIMENSIONS Gypsum blocks wall INSTALLATIONS installation ACTUATORS MF1/MF2 COMMUNICATIONS MODULES installation frame ACCESSORIES REPLACEMENTS The wall is composed of gypsum blocks (minimum density of 995 kg/m³), and with MAINTENANCE AND OPERATION minimum thickness of 70 mm. Possible damper orientations INSTALLATION FIRE DAMPER - FD 1.
Page 36
Flexible wall PRODUCT OVERVIEW installation DIMENSIONS MF1/MF2 INSTALLATIONS installation frame ACTUATORS MF1 (EI 60 (ve i↔o)S) COMMUNICATIONS MODULES The wall is made out of type A (EN520) gypsum plaster boards. To fulfill the classification it is NOT ACCESSORIES mandatory to use the mineral wool inside the wall (mineral wool with density up to 60 kg/m³...
Page 37
PRODUCT OVERVIEW DIMENSIONS Rigid floor/ceiling INSTALLATIONS installation ACTUATORS MF1/MF2 installation COMMUNICATIONS MODULES frame ACCESSORIES REPLACEMENTS The floor/ceiling is composed of concrete blocks (minimum density of 550 kg/m³) or MAINTENANCE AND OPERATION reinforced concrete (minimum density of 2200 kg/m³) and with a minimum thickness of 100 mm. Possible damper orientations INSTALLATION FIRE DAMPER - FD...
Page 38
PRODUCT OVERVIEW DIMENSIONS Shaft wall INSTALLATIONS installation ACTUATORS MF2 installation COMMUNICATIONS MODULES frame ACCESSORIES The wall is composed of 1x2 plasterboard boards, REPLACEMENTS 20 mm thick, installed on a steel frame construction. MAINTENANCE AND OPERATION Possible damper orientations INSTALLATION FIRE DAMPER - FD FD-MF2 Fire damper (B <...
Page 39
PRODUCT OVERVIEW DIMENSIONS Installation remote INSTALLATIONS from the rigid wall ACTUATORS (Promat) COMMUNICATIONS MODULES The wall is composed of concrete blocks ACCESSORIES (minimumdensity of 550 kg/m³) or reinforced concrete (minimum density of 2200 kg/m³) REPLACEMENTS and with a minimum thickness of 100 mm. MAINTENANCE AND OPERATION Installation only possible with FD40! Technical drawing...
Page 40
Installation remote PRODUCT OVERVIEW from flexible/rigid DIMENSIONS wall INSTALLATIONS Flexible wall: The wall is composed of 2x2 ACTUATORS plasterboard boards,12.5 mm thick, installed on a steel construction. To fulfill the classification it is NOT COMMUNICATIONS MODULES mandatory to use the mineral wool inside the wall (mineral wool with density up to 60 kg/m³...
Page 41
Battery assembly PRODUCT OVERVIEW installation DIMENSIONS INSTALLATIONS ACTUATORS The wall is composed of concrete blocks (minimum density of 550 kg/m³) or COMMUNICATIONS MODULES reinforced concrete (minimum density of 2200 kg/m³) and with a minimum thickness of 100 mm. ACCESSORIES Maximum dimension of fire dampers: 2X2 grid: 1500x800 mm REPLACEMENTS *For battery installation 2x2 use 8x connecting...
Page 42
PRODUCT OVERVIEW Battery assembly DIMENSIONS installation INSTALLATIONS (floor/ceiling) ACTUATORS COMMUNICATIONS MODULES ACCESSORIES The floor/ceiling is composed of concrete blocks (minimum density of 550 kg/m³) or reinforced REPLACEMENTS concrete (minimum density of 2200 kg/m³) and with a minimum thickness of 100 mm. MAINTENANCE AND OPERATION Maximum dimension of fire dampers: 2X2 grid: 1500x800 mm...
Page 43
PRODUCT OVERVIEW DIMENSIONS Battery assembly INSTALLATIONS installation ACTUATORS COMMUNICATIONS MODULES The wall is composed of blocks of aerated concrete ACCESSORIES (minimum density 550 kg/m³) and with a minimum thickness of 100 mm. REPLACEMENTS *For battery installation 1x2 use 2x connecting MAINTENANCE AND OPERATION frame.
Page 44
PRODUCT OVERVIEW DIMENSIONS Battery assembly INSTALLATIONS installation ACTUATORS COMMUNICATIONS MODULES The wall is composed of blocks of aerated concrete ACCESSORIES (minimum density 550 kg/m³) and with a minimum thickness of 100 mm. REPLACEMENTS *For battery installation 2x1 use 2x connecting MAINTENANCE AND OPERATION frame.
Page 45
PRODUCT OVERVIEW Multiple fire dampers DIMENSIONS installation INSTALLATIONS ACTUATORS Material compliant with the classification from COMMUNICATIONS MODULES Mineral wool 350 mm wide ACCESSORIES (140 kg/m³) REPLACEMENTS Damper blade must be closed during installation! MAINTENANCE AND OPERATION Prepare opening in the wall according to B (H) + 80 mm or 50% more (Weichschott/Firebatt installation- build the subframe according to the drawing,...
Page 46
Flexible wall subframe When installing the fire dampers in the flexible walls it is necessary to make a metal subframe PRODUCT OVERVIEW onto which the damper will be fixed with screws. Subframe should be prepared according to the DIMENSIONS drawings below. INSTALLATIONS FD25 FD40...
PRODUCT OVERVIEW DIMENSIONS MANUAL INSTALLATIONS ACTUATORS ACTUATORS R, R-S COMMUNICATIONS MODULES ACCESSORIES Manual operating mechanism, optionally with end switches (R-S). In case of fire, the fire damper closes REPLACEMENTS automatically. Damper closing can be initiated either by thermal fuse melting, or by manual activation on the MAINTENANCE AND OPERATION operating mechanism.
Page 48
PRODUCT OVERVIEW DIMENSIONS SOLENOID INSTALLATIONS ACTUATOR ACTUATORS EMS-S COMMUNICATIONS MODULES Electromagnetic operating mechanism, comes with ACCESSORIES end switches as standard. In case of fire, the fire damper closes automatically. Damper closing can REPLACEMENTS be initiated either by thermal fuse melting or remotely by triggering the electromagnet.
Page 49
PRODUCT OVERVIEW DIMENSIONS ELECTRIC INSTALLATIONS ACTUATOR ACTUATORS M24-S, M230-S, COMMUNICATIONS MODULES M24-S-ST ACCESSORIES Damper is delivered in closed position. When REPLACEMENTS electric actuator is connected to the power supply damper will open. When the damper reaches the end MAINTENANCE AND OPERATION position (damper open), the electro motor will stop.
ELECTRIC ACTUATOR Position of thermal PRODUCT OVERVIEW fuse DIMENSIONS INSTALLATIONS ACTUATORS COMMUNICATIONS MODULES H < 300 300 ≤ H ≤ 450 H > 450 ACCESSORIES Thermal fuse is located on the underside Thermal fuse is located on the same side Thermal fuse is located on the same side of the fire damper.
Page 51
PRODUCT OVERVIEW DIMENSIONS ELECTRIC INSTALLATIONS ACTUATOR ACTUATORS SCHISCHEK ExMax COMMUNICATIONS MODULES ACCESSORIES Damper is delivered in closed position. When electric actuator is connected to the power supply REPLACEMENTS damper will open. When the damper reaches the end position(damper open), in which is it blocked, the MAINTENANCE AND OPERATION electric actuator will stop.
ACCESSORIES Safety grill- Fire damper, safety grille and, if applicable, PRODUCT OVERVIEW extension piece are assembled at the factory to form a unit. The free cross sectional area of the cover grille is DIMENSIONS approx. 70%. INSTALLATIONS Flexible duct connections Flexible duct connectors are used in HVAC systems for isolation from structure- ACTUATORS...
Page 53
SMOKE SENSOR ASSEMBLY PRODUCT OVERVIEW FD-SSA DIMENSIONS AIR FLOW DIRECTION Smoke sensor assembly is developed to detect INSTALLATIONS smoke in ventilation ducts and combines a smoke detector and an adaptor system where both tube and ACTUATORS housing are specially designed for optimum airflow through the smoke detector.
Page 54
SMOKE SENSOR CASING ROTATION PRODUCT OVERVIEW Smoke sensor casing can be rotated (90°-180°-270°) in order DIMENSIONS to provide better flexibility for wiring. To rotate smoke sensor casing, follow the below instructions. INSTALLATIONS ACTUATORS 1. Follow first step of smoke sensor rotation: locate and re move hex screws.
Page 55
UPGRADE TO END CONTACTS (R25 R25-S) PRODUCT OVERVIEW DIMENSIONS INSTALLATIONS ACTUATORS COMMUNICATIONS MODULES ACCESSORIES REPLACEMENTS MAINTENANCE AND OPERATION REPLACEMENTS UPGRADE TO END FIRE DAMPER - FD FIRE DAMPER - FD CONTACTS (R40 R40-S) Video instructions 1. Locate hex screw, unscrew it and remove the cover. 2.
Page 56
PRODUCT OVERVIEW DIMENSIONS UPGRADE FROM INSTALLATIONS MANUAL (R40-S) ACTUATORS TO EMS COMMUNICATIONS MODULES ACCESSORIES To upgrade R40 to EMS, it is necessary to install kit for end contacts (FD-A-R40S-KIT). REPLACEMENTS To upgrade R25/RS25-S to EMS, it is necessary to install R40 mechanism (FD-A-R40) and kit for end MAINTENANCE AND OPERATION contacts (FD-A-R40S-KIT).
Page 57
PRODUCT OVERVIEW DIMENSIONS REPLACEMENT OF INSTALLATIONS THERMAL FUSE ACTUATORS (R25) COMMUNICATIONS MODULES ACCESSORIES REPLACEMENTS MAINTENANCE AND OPERATION Video instructions REPLACEMENTS FIRE DAMPER - FD 1. Find the hex screw located on the cover. Unscrew and remove the screw and the cover. 2.
Page 58
PRODUCT OVERVIEW DIMENSIONS REPLACEMENT OF INSTALLATIONS THERMAL FUSE ACTUATORS (R40) COMMUNICATIONS MODULES ACCESSORIES REPLACEMENTS MAINTENANCE AND OPERATION Video instructions REPLACEMENTS FIRE DAMPER - FD 1. Find the hex screw located on the cover, unscrew and remove the screw and the cover. 2.
Page 59
UPGRADE PRODUCT OVERVIEW TO ELECTRIC DIMENSIONS ACTUATOR INSTALLATIONS Manual ACTUATORS R25 <-> Belimo COMMUNICATIONS MODULES ACCESSORIES 100x200 to 800x600 The blade must be closed before replacement the REPLACEMENTS mechanism. MAINTENANCE AND OPERATION Video instructions REPLACEMENTS FIRE DAMPER - FD NOTE: Use Kit C (FD-A-KTC) to upgrade to electric actuator! * Before replacing the mechanism, the damper blade must be closed.
Page 60
UPGRADE PRODUCT OVERVIEW TO ELECTRIC DIMENSIONS ACTUATOR INSTALLATIONS Manual ACTUATORS R40 <-> Belimo COMMUNICATIONS MODULES ACCESSORIES 800x600 to 1500x800 The blade must be closed before replacement the REPLACEMENTS mechanism. MAINTENANCE AND OPERATION Video instructions REPLACEMENTS FIRE DAMPER - FD NOTE: Use Kit C (FD-A-KTC) to upgrade to electric actuator! *Before replacing the mechanism, the damper blade must be closed.
Page 61
HOW TO ROTATE PRODUCT OVERVIEW ELECTRIC DIMENSIONS ACTUATOR INSTALLATIONS (Belimo) ACTUATORS COMMUNICATIONS MODULES 100x200 to 1500x800 The blade must be closed before replacement the ACCESSORIES mechanism. REPLACEMENTS ERK Kit (FD-A-ERK) MAINTENANCE AND OPERATION • transition plate • rectangular shaft • 2x screws M6x30 Video instructions REPLACEMENTS...
PRODUCT OVERVIEW DIMENSIONS INSTALLATIONS ACTUATORS COMMUNICATIONS MODULES ACCESSORIES REPLACEMENTS MAINTENANCE AND OPERATION FIRE DAMPER - FD MAINTENANCE TRANSPORT MAINTENANCE AND FUNCTIONS It is not permitted to alter the dampers in any way nor perform any changes to their structure (except for the service procedures OPERATION After arrival, check the fire damper for transport damage 1) Release mechanism:...
Need help?
Do you have a question about the FD25 and is the answer not in the manual?
Questions and answers