Download Print this page

Advertisement

Quick Links

R Series Balances
AS R2.PLUS Analytical Balances
PS R1 Precision Balances
PS R2 Precision Balances
PS R2.H Precision Balances
USER MANUAL
IMMU-03-45-03-21-EN
www.radwag.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the PS 2100 and is the answer not in the manual?

Questions and answers

Summarization of Contents

General Information
Dimensions
Provides detailed measurements for different balance models and pan sizes.
Connectors
Identifies and explains the function of each connector on the balance.
Connection Cables - Diagrams
Illustrates wiring diagrams for connecting the balance to computers and printers.
PS R2.H Series
Details the features and specifications of the PS R2.H precision balances.
Intended Use
Specifies the intended laboratory applications for the X2 series balances.
Precautions
Outlines essential safety warnings and operational guidelines for balance use.
Warranty
Lists conditions under which the balance warranty becomes invalid.
Metrological Parameters Monitoring
Explains the importance of regular inspection of metrological characteristics.
User Manual Significance
Emphasizes the importance of reading the manual before operating the balance.
Balance User Training
Stipulates that only trained users should operate the balance.
Transport and Storage
Delivery Checklist
Instructions for checking the package and device upon delivery.
Package
Guidance on retaining and using original packaging for future transport.
Unpacking and Installation
Place of Use and Assembling
Defines suitable environmental and placement conditions for the balance.
Unpacking
Step-by-step instructions for safely removing the balance from its packaging.
Standard Delivery Components List
Lists all items included in the standard delivery package for the balance.
Settings
Details the procedure for leveling the balance before connecting it to power.
Maintenance Activities
Provides guidelines for cleaning different components of the balance.
Powering the Device
Explains how to correctly connect the balance to the power supply.
Connecting Additional Hardware
Advises on connecting peripherals and the importance of using manufacturer-recommended accessories.
Information on the Balance
Describes how to access informative details about the balance's status.
Start-Up
Temperature Stabilization Period
Specifies the necessary waiting time for the balance to reach thermal stability.
Ambient Conditions State Indication
Explains the function that indicates unstable ambient conditions for the balance.
User Menu
Overview of the balance's menu structure and function groups.
Logging
Procedure for logging in and managing user access levels and permissions.
Units
Enables changing mass unit availability and defining custom units.
Temporary Measuring Unit
Allows selection of a measuring unit to be displayed next to the mass reading.
Units Accessibility
Procedure for declaring which units are available for temporary selection.
Start Unit Selection
Defines the unit that the balance activates with upon startup.
Custom Unit
Allows declaration of two custom units based on indication multiplied by a coefficient.
Miscellaneous Parameters
Permissions
Allows choosing access levels for users to manage balance parameters and settings.
Key Press Sound
Enables or disables the audible beep sound upon key presses.
Display Brightness
Adjusts backlight brightness or turns off the display completely.
Backlight Turn-off Time
Sets the interval for the display to enter stand-by mode when inactive.
Auto Switch-off
Enables automatic display deactivation and balance standby.
Date Settings
Allows setting the current date on the balance.
Adjustment
Internal Adjustment
Describes the process of automatic and manual internal balance adjustments.
Adjustment Menu Settings
Details the options available within the adjustment menu for calibration.
Manual Adjustment
Provides procedures for manual internal, external, and user adjustments.
External Adjustment
Procedure for external adjustment using an external weight standard.
User Adjustment
Procedure for user-defined adjustment using an external weight.
Adjustment Report Printout
Explains the generation and content of the adjustment report.
Determining Printout Content
Adjustment Report
Defines parameters for declaring data to be printed on an adjustment report.
Header, Footer, GLP Printouts
Configures data elements for header, footer, and GLP measurement result printouts.
Non-standard Printouts
Details how to create and configure custom printouts with variable text.
Inserting Text
Explains how to insert text and variables into non-standard printouts.
Variables
Defines alphanumeric data variables used for printouts and product information.
Separator
Allows selection of the decimal point separator for mass indications.
Databases
Users
Manages user accounts, including access levels and language settings.
Products
Stores product information such as name, code, EAN, and weighing parameters.
Tares
Allows recording and managing tare weights for packaging.
Weighings
Describes the automatic saving and storage of weighing data.
ALIBI Memory
Details the ALIBI memory for storing a large number of measurements.
Export and Import of Databases
Database Export
Enables archiving and copying databases to external storage.
Database Import
Allows transferring database records from one balance to another.
Measurement Data Printout
Procedure for saving measurement data to an external USB flash drive.
Working Modes
Working Modes Accessibility
Allows enabling or disabling access to specific weighing functions.
Weighing Operation
Covers fundamental practices and procedures for weighing operations.
Dual Range Balance (PS 200/2000.R2)
Explains the dual range functionality and switching between accuracies.
Under-Pan Weighing
Describes how to perform weighing operations below the balance pan.
Counting Parts of the Same Mass
Parts Counting Mode Settings
Details mode-specific settings for the parts counting function.
Setting the Reference Mass: Mass Determination from the Sample of Known Quantity
Procedure to determine the mass of a single piece using a sample.
Setting the Reference Mass: Entering Mass Value
Procedure to manually enter the known weight value of a single piece.
Checkweighing
Declaring Threshold Values
Sets the low and high threshold values for checkweighing.
Dosing
Setting Target Mass: Entering Mass Value
Defines the target mass and tolerance for the dosing process.
Percent Weighing Control with Relation to Reference Mass
Setting the Reference Mass: Weighing Reference Sample
Procedure to set reference mass by weighing a sample representing 100%.
Setting the Reference Mass: Entering Mass Value
Procedure to manually enter a known reference mass value.
Animal Weighing
Additional Settings
Explains additional parameters like averaging time, threshold, and autostart.
Running the Process Manually – Means of Operation
Step-by-step guide for initiating the animal weighing process manually.
Running the Process Automatically – Means of Operation
Guide to setting up and running the animal weighing process automatically.
Density of Solids
Density Determination
Procedure for determining the density of solid materials using liquids.
Density of Liquids
Density Determination
Procedure for determining the density of liquid substances using a sinker.
Statistics
Means of Operation
How to acquire and process data from measurement series for statistical analysis.
Deleting Statistics
Procedure for removing statistical data collected from measurement series.
Totalising
Additional Settings
Allows disabling the printing of tare values in reports.
Means of Operation
Procedure for weighing individual ingredients and summing their total mass.
Peak Hold
Means of Operation
Explains how to capture and display the peak weight value applied to the pan.
Adding
Means of Operation
Procedure for adding net masses of weighed samples cumulatively.
Pipettes Calibration
Additional settings of pipettes calibration mode
Configures settings like volume determination and automatic taring for calibration.
Means of Operation
Step-by-step guide for performing pipette calibration procedures.
Communication
RS 232 Ports Settings (COM)
Configures serial port settings for RS232 communication.
WIFI Port Settings
Details the parameters and procedure for Wi-Fi network connection.
USB Port
Information on USB port types and their intended use for peripherals.
Peripheral Devices
Computer
Settings for connecting a computer for balance communication and control.
Printer
Configuration options for connecting and operating printers with the balance.
Barcode Reader
Settings for connecting and cooperating with a barcode reader.
Additional Display
Configuration for connecting an external additional display unit.
External Buttons
Enables cooperation with external TARE and PRINT buttons.
Cooperation with Peripherals
Transferred Data Format
Defines formats for data transfer to external devices via PRINT key or commands.
Communication Protocol
List of Commands
Provides a comprehensive list of commands for balance control and data acquisition.
Response Format
Explains the structure and meaning of responses received from the balance.
Additional Ecquipment
Anti-vibration table
A stable base designed to eliminate vibrations for precise measurements.
Rack for under-pan weighing
Accessory for under-pan weighing, magnetic loads, or density determination.
Density determination kit (for solids and liquids)
Optional kit required for density determination of solids and liquids.
Additional display
External display unit featuring a tilting option and a 1.5m cable.
AP2-1 current loop
Module for converting digital weight indication to an analogue value.