Table of Contents

Advertisement

INSTRUCTIONS
EVIS EXERA III XENON LIGHT SOURCE
OLYMPUS CLV-190
USA: CAUTION: Federal law restricts this device to sale by or on the order of a physician.
Labels and Symbols
Important Information — Please Read Before
Use
Summary of the Equipment Functions
Chapter 1
Checking the Package Contents
Chapter 2
Nomenclature and Functions
Chapter 3
Installation and Connection
Chapter 4
Inspection
Chapter 5
Operation
Chapter 6
Lamp Replacement
Chapter 7
Reprocessing, Storage,
Disposal, and Transportation
Chapter 8
Troubleshooting
Appendix
1
3
12
15
17
27
41
65
81
93
103
109

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLV-190 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Labels and Symbols
Rear and side panel
Identifies labels and symbols on the rear and side panels of the light source.
Front panel
Details labels and symbols found on the front panel of the light source.
Back cover of this instruction manual
Explains symbols and their meanings located on the back cover.
Important Information — Please Read Before Use
Intended use
Defines the specific applications and purpose of the light source.
Applicability of endoscopy and endoscopic treatment
Discusses the conditions and considerations for using the device in endoscopic procedures.
Instruction manual
Emphasizes the importance of reading and following the manual for safe operation.
Terms used in this manual
Defines key terms and components relevant to the light source and its operation.
User qualifications
Specifies the required qualifications and training for operating the light source.
Instrument compatibility
Guides on ensuring compatibility between the light source and ancillary equipment.
Repair and modification
Outlines restrictions on user servicing, repair, and modification of the device.
Signal words
Explains the meaning of danger, warning, caution, and note symbols used in the manual.
Dangers, warnings, and cautions
Details critical safety information, potential hazards, and precautions for using the light source.
Cardiac applications
Provides specific safety guidelines and considerations for using the device in cardiac procedures.
Summary of the Equipment Functions
Providing the examination light
Describes how the light source provides illumination for endoscopic examination.
Adjusting the examination light
Explains how to adjust the intensity of the examination light.
Optical-digital observation
Details the optical-digital observation modes available with the light source.
Transillumination function
Describes the function that enhances visualization through patient tissues.
Selecting the high intensity mode
Explains how to activate a higher light intensity for specific conditions.
Air and water feed
Details the function of supplying air and water through the endoscope.
Monitoring the operating hours of the examination lamp
Explains how to monitor the usage hours of the examination lamp.
Automatic switching to the emergency lamp
Describes the backup function of the emergency lamp during primary lamp failure.
Chapter 1 Checking the Package Contents
1.1 Checking the package contents list
Guides users on verifying all components are present and undamaged upon receipt.
Chapter 2 Nomenclature and Functions
2.1 Nomenclature and functions
Identifies and explains the various controls and indicators on the light source.
Rear and side panels
Details the components and connectors located on the rear and side panels.
2.2 Front panel
Describes the main operational controls and indicators on the front of the unit.
Control panel (buttons)
Explains the function of each button on the control panel for operating the device.
Control panel (indicators)
Details the various indicators on the control panel and their meanings.
2.3 Rear and side panels
Provides a detailed layout and description of the rear and side panel connections.
Chapter 3 Installation and Connection
3.1 Precautions for installation and connection
Outlines critical safety precautions and warnings before installing and connecting the equipment.
3.2 Installation workflow
Provides a step-by-step guide for the proper installation of the light source.
3.3 Installation of equipment
Details the procedures and considerations for physically installing the light source unit.
Installation on the mobile workstation (WM-NP2, WM-DP2, WM-NP1, WM-WP1, or WM-DP1)
Guides the installation of the light source onto specific mobile workstation models.
Installation in another location
Describes how to install the light source in locations other than a mobile workstation.
3.4 Installation of the water container
Explains how to install the water container when using the water feeding function.
3.5 Selection of the lamp ignition mode
Details how to select between manual and automatic ignition modes for the examination lamp.
Manual ignition (MANU)
Describes the manual process for igniting the examination lamp.
Automatic ignition (AUTO)
Describes the automatic process for igniting the examination lamp.
3.6 Connection of the video system center
Provides instructions for connecting the light source to the video system center.
3.7 Connection of the foot switch
Guides on connecting the optional foot switch to the light source.
3.8 Connection to the AC mains power supply
Details the procedures and safety precautions for connecting the device to electrical power.
Chapter 4 Inspection
4.1 Precautions for inspection
Outlines essential safety precautions and warnings before performing equipment inspections.
4.2 Inspection workflow
Presents a systematic checklist for inspecting the light source before use.
4.3 Checking the lamp ignition mode
Verifies the correct setting of the lamp ignition mode (manual/auto).
4.4 Connection of an endoscope
Details the process of connecting endoscopes to the light source for inspection.
Connection of a rigid endoscope
Specific steps for connecting rigid endoscopes.
Connection of a flexible endoscope
Specific steps for connecting flexible endoscopes.
4.5 Inspection of the power supply
Checks the power indicators, ventilation, and emergency lamp status.
4.6 Checking the lamp usage indicator
Guides on checking the lamp's remaining lifespan indicated on the usage indicator.
4.7 Inspection of the examination light
Verifies the proper functioning and emission of the examination lamp.
4.8 Inspection of the brightness mode selection function
Checks the ability to switch between automatic and manual brightness modes.
4.9 Inspection of brightness adjustment
Confirms that the light intensity can be adjusted correctly.
Inspection of automatic brightness adjustment
Validates the automatic adjustment of light intensity based on distance.
Inspection of manual brightness adjustment
Validates the manual adjustment of light intensity using control buttons.
4.10 Inspection of the optical-digital observation function
Verifies the functionality of special observation modes like NBI.
4.11 Inspection of the transillumination function
Checks the operation of the transillumination feature for enhanced visibility.
4.12 Inspection of the high intensity mode
Confirms the correct operation of the high intensity light mode.
4.13 Inspection of air and water feeding
Verifies the functionality of the air and water supply systems for the endoscope.
4.14 After inspection
Procedures to follow after completing the inspection, including turning off the device.
Chapter 5 Operation
5.1 Attention to operation
Highlights crucial safety precautions and user responsibilities during operation.
5.2 Operation workflow
Outlines the sequence of steps for using the light source effectively.
5.3 Turning the light source ON and igniting the examination lamp
Describes the procedure for powering on the device and activating the main lamp.
5.4 Setting the brightness mode
Guides on selecting the appropriate brightness mode based on the connected endoscope.
5.5 Brightness adjustment
Details how to adjust the light intensity for optimal viewing during procedures.
Automatic brightness adjustment
Explains the automatic adjustment of light output for consistent illumination.
Manual brightness adjustment
Describes how to manually control the light intensity using the device's buttons.
5.6 Optical-digital observation
Instructions for using specialized observation modes like NBI for enhanced imaging.
5.7 Transillumination function
Explains how to use the transillumination feature for improved visualization.
5.8 High intensity mode
Describes activating and using the high intensity light output mode.
5.9 Air/water feeding
Guides on using the air and water insufflation features through the endoscope.
5.10 Extinguishing the examination lamp
Details the procedure for turning off the main examination lamp.
5.11 Turning the light source OFF
Explains how to safely power down the entire light source unit.
Chapter 6 Lamp Replacement
6.1 Replacement of the examination (xenon) lamp
Provides essential safety warnings and procedures for replacing the xenon lamp.
6.2 Removal of the lamp
Step-by-step instructions for safely removing the old examination lamp.
6.3 Insertion of the lamp
Detailed guide on correctly installing a new examination lamp with heat sink components.
6.4 Lamp usage indicator reset
Explains how to reset the lamp usage indicator after a replacement.
Chapter 7 Reprocessing, Storage, Disposal, and Transportation
7.1 Reprocessing
Outlines the procedures for cleaning and disinfecting the light source and accessories.
7.2 Surface disinfectant cleaner
Recommends specific types of disinfectant cleaners and their properties for safe use.
7.3 Signs of degradation from reprocessing
Identifies visual indicators of damage or wear on the device after reprocessing.
7.4 Preparing equipment for reprocessing
Lists the necessary personal protective equipment and chemicals for reprocessing.
7.5 Reprocessing the light source and accessories
Details the workflow for cleaning and disinfecting the main unit and its accessories.
7.6 Storage
Provides guidelines for properly storing the light source to maintain its condition.
7.7 Disposal
Advises on the correct procedures for disposing of the equipment in compliance with regulations.
7.8 Transportation
Offers guidance on the safe transportation of the light source and its accessories.
Chapter 8 Troubleshooting
8.1 Troubleshooting
Introduces the troubleshooting section and general advice for resolving issues.
8.2 Troubleshooting guide
A comprehensive guide to identifying and resolving common problems with the light source.
8.3 Returning the light source for repair
Explains the process for contacting Olympus for repair services and necessary information.
Appendix
Combination equipment
Lists recommended combinations of Olympus equipment for use with the light source.
System chart
Illustrates compatible system configurations and connections for the light source.
Water container
Details compatibility of different water containers with various endoscope models.
Transportation, storage, and operating environments
Specifies environmental conditions for the device's operation, storage, and transport.
Specifications
Lists technical specifications, power requirements, dimensions, and weight of the light source.
EMC information
Provides electromagnetic compatibility (EMC) guidance and manufacturer declarations.
Guidance and manufacturer’s declaration — Electromagnetic immunity
Details immunity test levels and guidance for electromagnetic environments.

Table of Contents