Manual override function
If a mains switch is installed in the mains supply
lead, the light is capable of the following func-
tions in addition to the simple ON/OFF function:
Sensor operation
1) Switch light ON (when light is OFF):
Turn switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Turn switch OFF and ON once.
The light goes out or switches over to
sensor mode.
Reach setting / adjustment
With an assumed mounting height of 2.5 m,
the maximum reach of the sensor is 8 m. The
detection zone can be optimally adjusted ac-
cording to needs. The shroud provided can be
used for masking out any number of lens seg-
ments to shorten reach as required. This pre-
Technical specifications
Dimensions (H x Ø):
Output:
Switching capacity:
Connection:
Angle of coverage:
Reach:
Sensor system:
Time setting:
Twilight setting:
Manual override:
Enclosure (top/bottom):
Temperature range:
*VDE tested
Important: The switch should be operated
several times in rapid succession.
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The lamp is
set to stay on for 4 hours (red LED lights up
behind the lens). Then it returns automatically
to sensor mode (red LED off).
2) Deactivate manual override:
Turn switch OFF and ON once. The light goes
out or switches over to sensor mode.
vents the light from being activated uninten-
tionally, e.g. by cars, passers-by etc. and
allows you to target danger spots. The shroud
can be separated along the pre-grooved div-
isions in the vertical and horizontal directions
and applied to the lens.
82 x 51 mm
max. 1000 W (filament bulbs)*
max. 5 AX (fluorescent lamps)*
50 – 240 V~ / 5 A
230 – 240 V/50 Hz
360° with 180° angle of aperture
8 m max. all round
10 detection zones, 720 switching zones
5 sec. – 20 min.
2 – 2000 lux
4 hrs. selectable
IP 20
-20 °C to +50 °C
14
Troubleshooting
Malfunction
Cause
Without power
Fuse faulty,
not switched ON
Short circuit
Does not switch ON
Twilight setting in
night-time mode during
daytime operation
Bulb faulty
Power switch OFF
Fuse faulty
Detection zone not targeted
Does not switch OFF
Continued movement in
the detection zone
Light is in detection zone
and keeps switching ON
as a result of temperature
change
Keeps switching ON/OFF
Lamp being operated
in the detection zone
Animals moving in the
detection zone
Switches ON when it
Wind moves trees and
should not
bushes in the detection
zone
Cars in the street are
being detected
Sudden change in temp-
erature due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
LED flashes rapidly
Overload protection
activated
Remedy
New fuse, switch ON
mains switch, check lead
with a voltage detector
Check connections
Adjust setting
Replace light bulbs
Switch ON
New fuse, check
connection if necessary
Re-adjust
Check zone and re-adjust
or shroud if necessary
Change zone, or apply
shroud
Adjust zone, shroud or
increase distance
Adjust zone, or apply
shroud
Adjust zone or
apply shroud
Adjust zone or
apply shroud
Adjust zone, change
installation site
Switch OFF unit and
switch ON again after
cooling down
15